Loading...
HomeMy WebLinkAbout014-942-32-1106-LUP-2025-521'to"'pHc Wllrllill! Rich Lenroot Landing i Lenroot I x w- VICINITY MAP COMPLIANCE CODE ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 2015 IBC NATIONAL ELECTRICAL CODE (NFPA 70, NEC 2017 W/ AMINO) 2015 WISCONSIN MECHANICAL CODE (IMC 2015 W/ AMND) 2018 WISCONSIN UNIFORM PLUMBING CODE (UPC) 2015 WISCONSIN ENERGY CONSERVATION CODE (IECC 2015 W/ AMINO) 2015 WISCONSIN FIRE CODE (IFC 2015 W/ AMINO) WISCONSIN COMMERCIAL BUILDING CODE WISCONSIN UNIFORM DWELLING CODE (UDC) 2015 WISCONSIN FUEL GAS CODE (IFGC 2015 W/ AMND) UTILITY COMPANIES POWER COMPANY: XCEL ENERGY PHONE: (800) 895-1999 TELEPHONE COMPANY: CENTURY TEL PHONE: (800) 201-4102 tlrw YtlreTr� AMEMCAN TOWER° ATC SITE NAME: HARD ROCK WI ATC SITE NUMBER: 311256 T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 T-MOBILE SITE NUMBER: Al N0947A SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 SITE CLASS: SELF SUPPORT T-MOBILE ANCHOR AMENDMENT PLAN PH2Y_3-SEC LB+MB+TDD CONFIGURATION PROJECT SUMMARY SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD,WI 54843 COUNTY: SAWYER GEOGRAP4C COORDINATES: LATITUDE: 46-08351323 46° 5' •648" N LONGITUDE:-91-51333938 91" 30' 4a O22" W GROUND ELEVATION: 1322' AMSL ! PROJECT TEAM TOWER OWNER: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ENGINEER: ATC TOWER SERVICES LLC 1 FENTON MAIN, STE 300 CARY, NC 27511 PROPERTY OWNER: TREVOR J WHYTE 12454 NORTH STATE HIGHWAY 27 HAYWARD,WI 54843 APPLICANT: T-MOBILE PROJECT DESCRIPTION THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED AND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW: TOWER WORK: INSTALL MOUNT MODIFICATIONS, (3) ANTENNA(S), AND (1) 2 DO" HYSRIDTRUNK &24 4AWG 90M CABLE(S) EXISTING (3) ANTENNA(S), (6) RRU(S), AND (1) 2.00" HYBRID TRUNK 6/24 4AWG 90M CABLE(S) TO REMAIN GROUNDWORK: EXISTING (1) NOKIA SSC 600A SITE SUPPORT CABINET AND (1) NOKIE BATTERY CABINET TO REMAIN PROJECT NOTES 1. THE FACILITY IS UNMANNED 2 A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE 3 THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE. 4 NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSAL IS REQUIRED 5. HANDICAP ACCESS IS NOT REQUIRED 6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U-S.C- § 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THAT INVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDER CFR § 161000 (13)(7). PROJECT LOCATION DIRECTIONS 1. FROM NORTHBOUND 1-35W IN MPLS 55408 GO 26.8 MI; 2 I-35W N BECOMES 1-35 N. 37.9 MI; 3. TAKE THE MN-70 EXIT, EXIT 165, TOWARD ROCK CREEKIGRANTSBURG; 4. TURN RIGHT EAST ONTO MN-70 (CROSSING INTO WISCONSIN), 10.6 MI; 5- MN-70 BECOMES WI-70, 19.7 MI; 6. AT SIREN, WI TURN LEFT ONTO 2ND AVE/WI-35/WI-70- CONTINUE TO FOLLOW WI-70 E. 2.5 MI; 7. TURN RIGHT TO STAY ON WI-70 -- 0 1 MILES PAST LIND RD, GO 23.7 MI; IL ATSPOONER, WI TURN LEFT ONTO US63/N RIVER ST CONTINUE TO FOLLOW US-63 N. GO 28.1 MI; 9. AT HAYWARD, WI TURN LEFT ONTO WI-77/WI-27, 3.6 MI; 10. TURN RIGHT ONTO WI-27, 1.9 MI; 11, LOOK FOR ACCESS ROAD ON RIGHT EAST SIDE OF WI-27, WITH TOWER PEEKING OVER TREES SHEET Na SHEETINDEX i DESCRIPTION: REV: DATE: BY: - TITLE SHEET 0 9/30=6 j EDNA GENERALNOTES 0 9/30/2025 EDNA G-001 G-002 C-101 DETAILED SITE PLAN 0 0 0 9/30/2025 9/30/2025 EDNA EDNA EDNA C-201 TOWER ELEVATION C401 ANTENNA INFORMATION & SCHEDULE 9/30/2025 9/30/2025 C-501 CONSTRUCTION DETAILS 0 EDNA E-501 GROUNDING DETAILS 0 9/30/2025 EDNA E-601 PANEL SCHEDULE 0 9/30/2025 EDNA SUPPLEMENTAL SHEETS (3 PAGES) AMEFUCAN TOWER* ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION REV- DESCRIPTION BY DATE A, __F4R Cn{ STII LK"ON EDNA 9/30/2025 A— - A ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD,WI 54843 SEAL: Io \5 C SANTHOSHA �= SHANBHOGUE E-49097 s CARY .n NC `� t ,,r��r,�•��qq��0t4A liysigned ianthosCld bySanthosha ;hanbhog Shanbhogue Date: 2025.09.30 i e T • -Mobilew ATC PROD #: 15361603_GO OUST ID: HAYWARD WI-ATC 311256 OUST Al N0947A TITLE SHEET SHEET NUMBER: REVISION: G-001 0 GENERAL CONSTRUCTION NOTES: 1 OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY WILL PROVIDE AND THE CONTRACTOR WILL INSTALL A BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUND BUILDICO-LOCATE ONLY) B ACITELCO INTERFACE BOX(PPC) C ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GC TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION) D TONERS, MONOPOLES E TOWER LIGHTING F GENERATORS 6 LIQUID PROPANE TANK G ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING H ANTENNAS (INSTALLED BY OTHERS) I TRANSMISSION LINE J TRANSMISSION LINE JUMPERS K TRANSMISSION LINE CONNECTORS WTH WEATHERPROOFING KITS L TRANSMISSION LINE GROUND KITS M HANGERS N HOISTING GRIPS O BTS EQUIPMENT 22. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR ALL REQUIRED PERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THE CONTRACTOR 23. CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILE SPECIFICATIONS AND REQUIREMENTS 24 CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION 25 ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND AS SHOWN IN THESE PLANS 28 THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT 27. CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR SEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW AND 2 THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE APPROVAL COMPLETE INSTALLATION OF THE SITE INCLUDING. BUT NOT LIMITED TO, SUCH MATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB -FRAME FOR PLATFORM, 28 ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES, COPPER -CLAD ORXIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND DISCONNECT SWITCHES WHERE APPLICABLE. TEMPORARY ELECTRICAL POWER, CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS AND RUBBER MATTING, REPAR. CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS, MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES AND ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO 29 THE DRAWINGS AND SPECIFICATIONS IT IS THE POSITION OF T-MOBILE TO APPLY FOR PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED PERMITS 3 ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCAL 30 CODES, INCLUDING ANSIAEIAITIA-222, AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS 4 CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION, 5 CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REWIRED INSPECTIONS S ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND SITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALL DISCREPANCIES REPORTED TO THE ENGINEER t DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS B. DETAILS SHOWN ARE TYPICAL: SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS OTHERWISE NOTED 9. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR MEN THE PROJECT SCOPE REQUIRES THE USE OF THE SAFETY CLIMB, THE GENERAL CONTRACTOR SHALL ENSURE THE SAFETY CLIMB IS FREE OF OBSTRUCTIONS. NOT RUBBING ON OR TRAPPED BY ANY INSTALLED CUSTOMER EQUIPMENT, IS VISUALLY TAUT, MEETS MANUFACTURER INSTALLATION SPECIFICATIONS, AND IS FIRMLY SECURED AT ALL CABLE GUIDE LOCATIONS UPON PROJECT COMPLETION COMPLETION OF PROJECT SHALL NOT OBSTRUCT, TRAP, LOOSEN, OR OTHERWISE CAUSE FAILURE TO MEET MANUFACTURER INSTALLATION REQUIREMENTS FOR THE SAFETY CLIMB. CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WTH ALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALL NECESSARY SAFETY DEVICES INCLUDING PPE AND FIRM AND CONSTRUCTION DEVICES SUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING. TRENCH BOXESISLOPING. BARRIERS, ETC 31 THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD ANY DAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES. OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK OR TO HIS WORK OR THE NARK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS EXPENSE TO THE OWNER'S SATISFACTION 32. ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIP SHALL BE SUBJECT TO THE APPROVAL OF THE T-OBILE REP ANY WORK FOUND BY THE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BE REPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS OBTAINED 33 IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF MATERIALS LISTED HEREINAFTER BY MANUFACTURER'S NAMES ANDIOR MANUFACTURER'S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERS AS SPECIFIED 10 CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED THESE ELEMENTS AREAS FOLLOWS: LATERAL BRACING, 34 T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED -UP AT THE T-MOBILE WAREHOUSE, ANCHOR BOLTS, ETC. NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTED AND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REWIRED TO PLACE 11 CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS THE EQUIPMENT IN OPERATION, READY FOR USE THE CONTRACTOR SHALL BE DRAINS, DRAIN PIPES, VENTS, ETC BEFORE COMMENCING WORK RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP 12 INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILE REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION, ANY SUCH REMEDIAL ACTION SHALL REQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING 13 EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. 14 CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS PROJECT TO MATCH EXISTING PRE -CONSTRUCTION CONDITIONS TO THE SATISFACTION OF THE T-MOBILE CONSTRUCTION MANAGER, 15 ALL CABLEICONDUIT ENTRYIEXIT PORTS SHALL BE WEATHERPROOFED DURING INSTALLATION USING A SILICONE SEALANT. 16 WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET, CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORD IMMEDIATELY �t CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE AND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. 18 CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF EACH DAY 19 CONTRACTOR SHALL COORDINATE WORK SCHEDULE WTH AMERICAN TOWER CORPORATION (ATC)AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY 20 CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC) WITH A POF MARKED UP AS -BUILT SET OF DRAWINGS UPON COMPLETION OF WORK 35 T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANY EQUIPMENT OR MATERIALS WHICH. IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH THE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THE EQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO T-MOBILE OR THEIR ARCHITECT/ENGINEER SPECIAL CONSTRUCTION ANTENNA INSTALLATION NOTES: 1 WORK INCLUDED: A ANTENNA AND COAXIALIHYBRID CABLES ARE FURNISHED BY T-MOBILE UNDER A SEPARATE CONTRACT THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS ERECTION ON SHALL BE RESPONSIBLE FOR THE PROTECTION OF PERSONNEL B INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND T-MOBILE SPECIFICATIONS C INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS D INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE E INSTALL COAXIAUHYBRID CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS WEATHERPROOF ALL CONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURERS REQUIREMENTS. TERMINATE ALL COAXIAL/HYBRID CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED 21. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WTH T-MOBILE REP 2 ANTENNA AND COAXIAUHYBRID CABLE GROUNDING: TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED ALL ITEMS NOT PROVIDED SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR CONTRACTOR WILL INSTALL ALL ITEMS PROVIDED A ALL EXTERIOR #B GREEN GROUND WRE'DAISY CHAIN' CONNECTIONS ARE TO BE WEATHER SEALED WTH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OR EQUAL B ALL COAXIAUHYBRID CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIAUHYBRID CABLE (NOT WITHIN BENDS) ALL DISCREPANCIES FROM WHAT 15 SHOWN ON THESE CONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATC ENGINEERING IMMEDIATELY FOR CORRECTION OR RE -DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING OR ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. AMERICAN TOWER# ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069.11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION RE``V DESCRIPTION BY DATE //AD FOR C0N9MWTI0N EDNA w30/2025 A A/� A ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD,WN 54843 SEAL: ►►�111i�HI111I1��, °Hsi'''%, ma's SANTHOSHA SHANBHOGUE E-49097 Svc CARY w= IIM Digitally Signed 2025-09-30 T - -Mobile ATC PROD, M 1638tS93_GO CUST. ID: HAYWARD WN-ATC 311256 OUST. #: JAIMM7A GENERALNOTES SHEET NUMBER: REVISION: G-002 0 I SITE PLAN NOTES: THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2 ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS 3 NO ELECTRICAL SCOPE IS INCLUDED IN THIS PROJECT. LEGEND ® GROUNDING TEST WELL ATS AUTOMATIC TRANSFER SWITCH B BOLLARD CSC CELL SITE CABINET D DISCONNECT E ELECTRICAL F FIBER GEN GENERATOR G GENERATOR RECEPTACLE HH, V HAND HOLE, VAULT IB ICE BRIDGE K KENTROX BOX LC LIGHTING CONTROL M METER PB PULL BOX PP POWER POLE T TELCO TRN TRANSFORMER CHAINLINK FENCE PROPOSED CABLE NOTES: 1 ESTIMATED LENGTH OF PROPOSED CABLE IS 286'. ESTIMATED LENGTH OF CABLE WAS PROVIDED BY CUSTOMER OR CALCULATED BY ADDING THE RAD CENTER AND THE DISTANCE FROM THE SHELTER ENTRY PLATE TO THE TOWER (ALONG THE ICE BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF IS% (OF THE TWO PREVIOUS VALUES), COS DEFER TO GREATEST CABLE LENGTH. 2 ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE EXISTING CABLE SUPPORT STRUCTURES AS PROVIDED FOR CARRIER TO ADEQUATELY SECURE CABLES, USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP -INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. OTHERWISE, ATTACH CABLES TO HORIZONTAL OR DIAGONAL TOWER MEMBERS USING PROPOSED STAINLESS STEEL ADAPTERS (DO NOT ATTACH TO TOWER LEG) — — x c x Yy l]]] GEL SURFACEI l< r� I X X I 4CL 13 n I x x SELF SUPPORT TOWER It* X 26' SHELTER 1 DETAILED SITE PLAN GRAPHIC SCALE N 7u a fa z0 (IN FEET) 1 UNIT =20 FEET xt x EXISTING T-MOBILE 8' X 8' PLATFORM 1 WITHIN A 10' X 12' GROUND SPACE R-80 (MODIFIED AS REQUIRED FOR UPGRADE FROM 8790AH-SR-T 6X24 TO PHZY 3-SEC LB+M B+TDD CONFIGURATION) PROPOSED (1) ABIP INSIDE EXISTING CABINET - - EXISTING NOKIA BATTERY CABINET TO REMAIN EXISTING NOK14 SSC 600A SUPPORT CABINET TO REMAIN EXIS71NG (1) 2.00" HYBRID TRUNK 6124 4AWG 90M (TO REMAIN) PROPOSED (1) 2 00" HYBRID TRUNK 6124 4AWG 90M (SEE PROPOSED CABLE LENGTH NOTES ON THIS PAGE FOR LENGTH AND ROUTING GUIDELINES) i'. AMERICANTOWER* - ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 �? PHONE: (919) 468-0112 [ 406941 THE USE AND PUBLICATION OF THESE DRAWINGS I% SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION REV DESCRIPTION BY DATE /0, FOR CONSTRUCTION EQNA_2 n ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD,WI 54843 SEAL: ■ lkIIIII)1111I' li SANTHOSHA SHANBHOGUE E-49097 �v CARY w �O.e■ N *"?r ,,,���►0IN IIl11f11�t■■■ ■■ Digitally Signed: 2025-09-30 T --Mobi.lew ATC PROD. 0: 15361603 GO DUST. ID: I HAYWARD WI-ATC 311256 OUST.#: JAIND947A DETAILED SITE PLAN SHEET NUMBER: REVISION: C-101 0 C TOP OF EXISTING kiGk1EST .4PPt11�tL•'AEM'C'!' TOP OF EXISTIA I EXISTING AND 1 2 PROPOSED T-MOBILE 6p EQUIPMENTAND MOUNT MODIFICATIONS EXISTING (1) 2.00" HYBRID TRUNK 6124 4AWG 90M (TO REMAIN) PROPOSED (1) 2.00" HYBRID TRUNK 6124 4AWG 90M (286) (SEE CABLE NOTES ON C-101) TOWER ELEVATION SCALE: N T S EXISTING CARRIER ANTENNAS RAD CENTER ® ELEV 246 EXISTING T-MOBILE RAD CENTER ® 230' EXISTING TOWER rxfsn ' CRAbF f� ELEV ❑' —11117 PER MOUNT ANALYSIS COMPLETED BY ATC, DATED 8/27125, THE EXISTING MOUNT MUST BE MODIFIED TO ADEQUATELY SUPPORT THE PROPOSED LOADING THE MOUNT MODIFICATION PROPOSED IN THE MOUNT ANALYSIS, INCLUDED AT THE END OF THIS PLAN SET, MUST BE INSTALLED PRIOR TO THE INSTALLATION OF THE PROPOSED ANTENNAS AND OTHER EQUIPMENT AMERICAN TOWER' ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS I SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV DESCRIPTION BY DATE �0 FL7R CO��R �[�'jlpj�. EDNA 9I30/2025 ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD,WI 54843 SEAL: 1111 fit". l0 f+ ``v SANTHOSHA SHANBHOGUE E-49097 = CARY �.n NC = = OrNiAi`` Digitally Signed: 2025-09-30 M • -Mobile ATC PROJ. #: 15361603 GO CUST ID: HAYWARD WI-ATC 311256 COST.#: JAIN0947A TOWER ELEVATION SHEET NUMBER: REVISION: C-201 0 EXISTING FFW-65C-R2N23 ANTENNA TO REMAIN (1 PER SECTOR) (TYP, 3) EXISTING AHLOA RRU TO REMAIN (1 PER SECTOR) (TYP. 3) EXISTING TOWER LOCATION SECTOR I RAD I AZ I POS ANTENNA ALPHA 1230' I 0' 1 A 1 I FFW-65C-R2N2 BETA 1 230' 1120' 1 81 1 FFW-65C-R2N2 GAMMA I230'l240'I C1 I FT-65C-R2N2 6�i 4HFll EMAIN ECTOR) (TYP. 3) EXISTING SECTOR MOUNT (TYP.) I EXISTING ANTENNA PLAN N SCALE: N T 8 PROPOSED AVHA ANTENNA ::u (1 PER SECTOR) (TYP. 3) A2 EXISTING AHLOA -J RRU TO REMAIN (1 PER SECTOR) (TYP 3) EXISTING TOWER - C1 PER MOUNT ANALYSIS COMPLETED BY ATC, DATED 8127125, THE EXISTING MOUNT MUST BE MODIFIED TO ADEQUATELY SUPPORT THE PROPOSED LOADING, THE MOUNT MODIFICATION PROPOSED IN THE MOUNT ANALYSIS, INCLUDED AT THE END OF THIS PLAN SET, MUST BE INSTALLED PRIOR TO THE INSTALLATION OF THE a 0 PROPOSED ANTENNAS AND OTHER EQUIPMENT. - - EXISTING FFW-65C-R2N23 3 ANTENNA TO REMAIN (I PER SECTOR) (TYP. 3) Al .. EXISTING AHFII RRU TO REMAIN (1 PER SECTOR) (TYP. 3) - EXISTING SECTOR MOUNT (TYP.) 02 R B1 ° PROPOSED MOUNT MODIFICATIONS C2 (REFER TO SHEETS AT THE END OF THIS PLAN SET) �1 FINAL ANTENNA PLAN N SCALE: N T 8 EXISTING ANTENNA SCHEDULE 3 3 3 NOTES 1. GC TO VERIFY THE FINAL RFDS LOCATION ANTENNASL"AARY FINAL ANTENNA SCHEDULE ANTENNA SUMMARY _ NON ANTENNA SUMMARY NON ANTENNA SUMMARY MECH/ELEC BAND STATUS ADDITIONALTOWERMECHIELEC STATUS MATCHES THE FINAL CONSTRUCTION DRAWINGS AZ POS ANTENNA SECTOR RAID BAND STATUS ADDITIONAL TOWER STATUS D-TILT MOUNTED EQUIPMENT GC TO NOTIFY ATC PM OF ANY DISCREPANCY PRIOR TO 0.TILT MOUNTED EQUIPMENT N600, L700, L600, N600, L700, L600, L2100, L 1900, 0%2- RMN AHLOA RMN INSTALLING THE EQUIPMENT. Al FFW-65C-R2N23 L2100, L 1900, 0%2- RMN AHLOA RUN N1900, LAWS3, AHFII RMN 2 GC TO CAP ALL UNUSED ALPHA 230' 0° N1900, LAWS3, AHFII RMN PORTS. 3. GC TO CONFIRM SPACING OF N600, L700, L600, A,2 AVHA N2500 0°/2° ADD - L2100, L 1900, 0%2' RMN AHLOA RMN PROPOSED EQUIP DOES NOT CAUSE TOWER CONFLICTS N600, L700, L600, N 1900, LAWS3, N2100 AHFII RMN NOR IMPEDE TOWER CLIMBING PEGS. STATUS ABBREVIATIONS BETA 230' 120° 81 FFW-65C-R2N23 L2100, L 1900, N1900, LAWS3, N2100 0%2' RMN AHLOA RMN AHF11 RMN NW0, 1. 700, L 6170, f 2100, L 1900, 0%2' RMN AHLOA RMN 82 AVHA N2500 0•/2° ADD NT!1W LAWS3, N2100 AHFII RMN RMV: TO BE REMOVED RMN: TO REMAIN AHLOA RMN C7 FFW-65C-R2N23 N600, L700, L600, L2100, L 1900, 0%2' RMN REL: TO BE RELOCATED GAMMA 230' 240° N1900, LAW53, AHFII RMN ADD: TO BE ADDED N2100 c2 AVHA N2500 0°/2° ADD CABLE LENGTHS FOR JUMPERS JUNCTION BOX TO RRU: 16- RRU TO ANTENNA: 10' EXISTING FIBER DISTRIBUTION I OVP BOX EXISTING CABLING SUMMARY MODEL NUMBER STATUS CABLE CITY, SIZE, TYPE STATUS (1) 2.00" HYBRID TRUNK 6124 4AWG RMN 90M FINAL FIBER DISTRIBUTION / OVP BOX FINAL CABLING SUMMARY r n MODEL NUMBER STATUS CABLE CITY, SIZE, TYPE STATUS I EQUIPMENT" SCHEDULES - _ (1) 2.00" HYBRID TRUNK 6/24 4AWG RMN ,1 90M - - (1) 2.00" HYBRID TRUNK 6124 4AWG 90M ADD a m AMERICAIV TOWER' ATC TOWER SERVICES LLC 1 FENTON MAIN -j SUITE 300 n. CARY, NO 27511 ti PHONE: (919) 468-0112 a 4069.11 THE USE AND PUBLICATION OF THESE DRAWINGS U SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR 2 WHICH THEY ARE PREPARED ANY USE OR c DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER c9 IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING 18SUPERSEDED BY THE LATEST VERSION REV, DESCRIPTION BY DATE Q FOR QONSTRUGTION EDNA VM=25 0 - ^A- ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD,W154843 SEAL: ��11l1t11111111111j \SC •�° SANTHOSHA SHANBHOGUE E-49097 = CARY W NC ,Z4%, tl�ffjj1111111 Digitally Signed: 2025-09-30 T - -Mobile ATC PROJ. A 15201 S03 D0 CUST.ID: HAYWARD WI-ATC 311255 OUST. p: lAlNO947A ANTENNA INFORMATION & SCHEDULE SHEET NUMBER: REVISION: C-401 0 EXISTINGIPROPOSED MOUNTS AND/OR MOUNT MODIFICATIONS NOT SHOWN FOR CLARITY. REFER TO ANTENNA PLANS, MOUNT ANALYSES AND/OR MOUNT MODIFICATION DOCUMENTS FOR ADDITIONAL DETAIL PROPOSED ANTENNA W/BRACKET PER MANUFACTURER EXISTING OR PROPOSED MOUNTING PIPE PROPOSED 513 ANTENNA MOUNTING DETAIL - TYPICAL SCALE: N T S a id AMERICANTOWeR' ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 f PHONE: (919) 468-0112 a 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS y SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED, ANY USE OR c DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION REV. DESCRIPTION BY DATE A0 FOR•CONSTRUCTION EDNA W30/2025 A- A A ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD.W154843 SEAL: ��•`' co Ns �'''f•, SANTHOSHA SHANBHOGUE E-49097 = CARY NC 111 Digitally Signed: 2025-09-30 T • -Mobile ATC FROJ. V. 15381603 GO CUST- ID: HAYWARD WI-ATC 311256 CUST. V. JAIN0947A CONSTRUCTION DETAILS SHEET NUMBER: REVISION: C-501 0 PROPOSED ANTENNA EXISTING ANTENNAS � _ ` PROPOSED JUMPER PROPOSED CONNECTOR AND TO EXISTING-_-. — — WEATHERPROOFING KIT ANTENNA MASTS ,+ PROPOSED WEATHERPROOFING KIT EXISTING COAX _ GROUND KITS - ' _ PROPOSED CABLEji 2 1 GROUND KIT •6Qs =� ANTENNA CABLE TO CABINET (TYP.) 4 #6 AWG STRANDED CU \ 5 WIRE WITH GREEN, 60OV, 1 THWN INSULATION GROUNDING - CONNECTION TO EXISTING TMA, �\ I EXISTINGGROUNDING GROUND BAR MOUNTED TO }� 50 ,y. NEARIBELOW ANTENNA LIGHTNING (TO BE INSTALLED IF - PROTECTION SYSTEM REQUIRED) NOTES: ' 1 THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS SLIGHT ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THE CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THE CONSTRUCTION MANAGER OF ANY CONFLICTS 2. SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATEST EDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN �Z TYPICAL ANTENNA GROUNDING DIAGRAM �� SCALE: N T S TO ANTENNA ANTENNA CABLE 2 1/2"0 MAX GROUNDING KIT PER CABLE MANUFACTURER'S RECOMMENDATIONS (ANDREW OR APPROVED EQUAL) #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) f0 GROUND BAR TO EQUIPMENT GROUND KIT NOTES: 1 DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR, 2 CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PART NUMBER 221213) AND INSTALLITAPE PER MANUFACTURER'S SPECIFICATIONS CABLE GROUND KIT CONNECTION DETAIL �� SCALE: N T S STANDARD CONDUIT USE TABLE C ONURMC USE CASE LOCATION USE CASE EXAMPLE TYPEIT I ABOVEGROUND (METALLIC) AC, DC COMM ABOVE GROUND PPC TO SSC UNDERGROUND PPC TO SSC OR BACKHAUL PVC AC POWER UNDERGROUND TRANSPORT HUB TO SSC MAX 8' PER CONDUIT RUN, TIGHT LOCATIONS BETWEEN HUB AND CONDUIT BUT NOT LFMC AC, DC, COMM ABOVE GROUND ONLY TO BE USED WHERE IT CAN BE STEPPED ON EMT INDOOR AC, DC INDOOR NOT EXPOSED TO THE OUTDOOR CIRCUIT PANEL TO JUNCTION BOX COMM ENVIRONMENT (MUST BE DRY) LFNC GROUND CONCEALING AND P TING BTCW RISERS GROUND RING TO MGB OR SEC WIRE ONLY EXCEPTION CONDUIT USE TABLE CONDUIT USE CASE LOCATION I USE CASE EXAMPLE TYPE EMT OUTDOOR DC, OUTDOOR WHEN USED WITH WATERTIGHT BETWEEN EQUIPMENT AND BATTERY CABINET OR (NOT PREFERRED) COMM HUBS ONLY EQUIPMENT TO EQUIPMENT CABINETS FOR INTER CABINET CONNECTION MAT BE USED AS A LOWER COST ALTERNATIVE TO RMC OUTDOORIINDOOR NONMETALLIC NEC PER NEC ABOVE GROUND METALLIC RMC, MUST MEET OR EXCEED FEDERAL SPEC: (ALUMINUM) GUI V V-G-540C, UL-0A, ANSI C80.5, NEC 344.10 (A) ALLOWS THE USE OF EITHER ALUMINUM OR GALVANIZED FITTINGS , CONDUIT USE TABLES PROPOSED CABINET #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR I �I 1 — EXISTING EQUIPMENT GROUND BAR (TYR) r,�\ CABINET GROUNDING DETAIL SCALE: N T S 3a, x I'1n" SS BOLT 3/8" SS LOCK WASHER (EACH SIDE) (EACH SIDE) az lz °0 o o sr A 9 �r - ' 1/4" X 4" X 8" GROUND BAR (ERICO PIN: EGBA14406CC OR EQUAL) TWO -HOLE LUG, TO BE USED WITH #2 AWG BCW (LOWER TOWER GROUND BAR ONLY) GROUND BAR NOTES: 1 GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS, WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S) 2 GROUND BAR TO BE BONDED DIRECTLY TO TOWER, 3l TOWER GROUND BAR DETAIL SCALE: N T S ELECTRICAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. 2 ATC HAS NOT VERIFIED ANY EXISTING T-MOBILE GROUND EQUIPMENT OR ELECTRICAL LOADING PROPOSED WORK BASED ON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE, CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HAS SUFFICIENT SPACE FOR PROPOSED BREAKER. PROPOSED CABLE AND CONDUIT SHALL BE MINIMUM SIZE PER BELOW IN CHART 3 FOR SPECIFIC CABINET /ANCILLARY EQUIPMENT WIRING REQUIREMENTS, THE T-MOBILE CONTRACTOR SHOULD REFERENCE DESIGN DOCUMENTS PROVIDED BY T-MOBILE FOR THIS CURRENT PROJECT CONFIGURATION, IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS & NEC STANDARDS & PRACTICES. 1 VOLTS OCPD SIZE WIRE SIZE GROUND CONDUIT 80A2P 3aKi AWG #8 AWG 1-1/4' 20240V 1002P 3-#2 AWG #B AWG 1-1/4' OR 125Al2P 34MOAWG #SAWG Z' 0/208V 150AQP MOO AWG #8 AWG 2" 20QA2P UM AWG #a AWG 2' BOA2P 2al3 AWG #6AWG 1-1/4' 240V 10aw 2-02 AWG #8 AWG 1-1/4' OR 125A2P 24M/O AWG BB AWG 2' 208V 150A2P 24/3I0 AWG #B AWG 2" I 20OA2P 2-#3/O AWG tb AWG Y ELECTRICAL NOTES a? ANIERICANTOWER• WS ATC TOWER SERVICES LLC 6 1 FENTON MAIN' SUITE 300 -• CARY, NC 27511 O PHONE: (919) 468-0112 d 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR n WHICH THEY ARE PREPARED ANY USE OR c DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER Ij IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION REV DESCRIPTION BY DATE QO FQA-QQNSTRUCTION EDNA 9 MIY A ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, W 154843 SEAL: SANTHOSHA SHANBHOGUE E-49097 �= w CAW w N `4*1 11rrllrrl1111111��� Digitally Signed: 2025-09-30 T --IVlVUllq-,- ATC PROJ MI 15361602LGO CUST. ID: HAYWARD WI-ATC 3112M CUST.#: AlNO947A I GROUNDING DETAILS SHEETNUMBER: REVISION: E- 1 0 ELECTRICAL NOTES a? ANIERICANTOWER• WS ATC TOWER SERVICES LLC 6 1 FENTON MAIN' SUITE 300 -• CARY, NC 27511 O PHONE: (919) 468-0112 d 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR n WHICH THEY ARE PREPARED ANY USE OR c DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER Ij IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION REV DESCRIPTION BY DATE QO FQA-QQNSTRUCTION EDNA 9 MIY A ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, W 154843 SEAL: SANTHOSHA SHANBHOGUE E-49097 �= w CAW w N `4*1 11rrllrrl1111111��� Digitally Signed: 2025-09-30 T --IVlVUllq-,- ATC PROJ MI 15361602LGO CUST. ID: HAYWARD WI-ATC 3112M CUST.#: AlNO947A I GROUNDING DETAILS SHEETNUMBER: REVISION: E- 1 0 SANTHOSHA SHANBHOGUE E-49097 �= w CAW w N `4*1 11rrllrrl1111111��� Digitally Signed: 2025-09-30 T --IVlVUllq-,- ATC PROJ MI 15361602LGO CUST. ID: HAYWARD WI-ATC 3112M CUST.#: AlNO947A I GROUNDING DETAILS SHEETNUMBER: REVISION: E- 1 0 PANEL TYPE LIGHTING & APPLIANCE SYSTEM 120/24OV, 10, 3W, 24 CKT LOCATION: TENANT EQUIPMENT LEASEAREA DESIGNATION: TENANT PANEL MOUNTING: SURFACE MAIN BREAKER(MB): 200A ENCLOSURE NEMA 3R MAIN BUS RATING: 200A PANEL NOTES: EXISTING MN A 10. RATING: WA CONNECTED FEEDER OR BRANCH CIRCUIT FEEDER OR BRANCH CIRCUIT CONNECTED LOAD(kVA) BRIEF DESCRIPTION BREAKER CIRCUrr POLE NO POLE NO. CI I BREAKER BRIEF DESCRIPTION LOADNVA) A B AMPS POLES WIRE GND COND. COND. GND WIRE POLES AMPS A B ❑18 GFCI INTERNAL 15 1 1 ( 1 3 2 QOD 011, GFCI EXTERNAL 15 1 1 3 1 3 3 4 S 2 150 SSCN2150A 7� 7.2D 0.50 1ECHLK#iT 2f1 1 5 3 0.00 7 B 0.00 0.00 9 10 R00 0.00 11 12 ODD O.00 13 14 0.00 0.D0 15 18 O.DO Q W 17 3 18 2 ISO SSC M7 150A 720 7.Z0 0.00 19 O.OD _ 21 22 Q.00 p,pp 23 24 O.W 07 0.2 A B TOTAL 144 144 15.1 14.8 7A7 CONNECTED LOAD (WA) 1 .1 14.8 29.7 DEJA Nn LOAD(kVA) DERATING FACTOR(80%) CIRCUIT NOTES DEMANDLOAD SIZING: 154 AMPS 1) PANEL SCHEDULE BASED ON NFO PROVIDED TO AR IF PANEL HAS DIFFERENT EXISTING LOADS THAN SHOWN, STOP WOW AND CONTACT FOR 2) EXISTING CIRCUIT, UNKNOWN LOAD, MAX DEMAND ASSUMED FOR LOAD CAPACITY ASSESSMEM, 3) EXISTING CIRCUIT, KNOWN LOAD FOR LOAD CAPACITY ASSESSMENT 4) PROPOSED CIRCUIT, KNOWN LOAD FOR LOAD CAPACITY ASSESSMENT 5) EXISTING CIRCUIT DEMdD. S) EXISTNGC97CUITDEMO'D, BREAKER REPLACED AS SHOWN A NO CIRCUIT AS PROPOSED, MAX DEMAND FOR LOAD CAPACITY ASSESSMENT 7) EXISTINGCMCUTDBIO'D, BREAKER REPLACED AS SHOWN AND CIRCUIT AS PROPOSED, KNOWN LOAD FOR LOAD CAPACITY ASSESSMENT ;1 PANEL SCHEDULE I ELECTRICAL NOTES: 1. THIS DIAGRAM REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT 2 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. 3 ATC HAS NOT YET VERIFIED ANY EXISTING T-MOBILE GROUND EQUIPMENT OR ELECTRICAL LOADING PROPOSED WORK BASED ON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE. CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HAS SUFFICIENT SPACE FOR PROPOSED BREAKER A, AM0PJCAN TOWER• ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069.11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION REV. DESCRIPTION BY DATE /O^0 —.F48I� CORUCTION.. gDNA 1p3W2n29 L.\ An L` ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD,WI 54843 SEAL, SANTHOSHA SHANBHOGUE =� E 7 CARY w So le Nell VON C �n ni Digitally Signed: 2025-09-30 T •-Mobilew ATC PROD.M 15381503-00 CUST ID: 114AYWAnD WI-ATC 311256 CUST.IV JAINO847A PANEL SCHEDULE SHEET NUMBER: REVISION: E-601 0 Proposed RAH Equipment rmpuer_ PI►+er_s.s�, Le.rde»Too Enemrun 1 Z d _. Enebsurn 7"s tuaw Tcp mound eomsn. c e+.e! S.1wry crr rl6 fir►] Rtlo ar�uw4 ►u�su�� Mbe Lroo N1 �1too LIL44M Zuk 'AM js4 1 Kim LlrpO 1QIop Sbmdub d suenroa MINI AU40.2) ASILIc2) LIM N= 1.211A ARIL4x� r 1wo Srr�brand 8ubraet +�Y+►IhZ! I R I>ff6e V2 Pm2) gyEleld Cobb swoon RAN seo" or wort: 07n5 41[, PRFDS Cumled Hy6aid Tlunll 9121 MIVIKigum {) CABINET CONFIGURATION 56r9CElIFI erl 'rl! ' For 5G and LTE Airscale B9 dimensioning refer to Fib Part matrices. (Alpha, Beta & Mamma) G u' Me°v" FDD - Lowban 1 Pxdr» AnOuw 912 (L700) — S MHz lie B71(L600) —10 MHz ;jj j B71(N600) —15 MHz I Mt1iln•+�1 lvrglQ $ I 6 S' » % ! l AHLOA I AHFII 7M4600 AWS+PCS FDD - Mldband 84/8% (L2100) — 20 MHz B66 (N2100) — 20MHz 52 (L1900) — 20 MHz B25 (L1900) — 20 MHz 925 (N 1S00) — 20MHz SRAN — GSM PCS TDD - Bend 41 N41(2,5GHz)—100MHz +80MHz 6K24 16xz� Hybrid l Hybrid } F5ti AkIM . --- r SRAN LTE 1 i I LTE FDDITDD Alrscelel 2 ANTENNA CONFIGURATION NOTE: THIS SHEET CREATED BY OTHERS AND THIS SHEET CREATED BY OTHERS AND PRO%ADED BY REQUEST OF CUSTOMER WITHOUT EDIT. SUPPLEMENTAL SHEET NUMBER: REVISION R-601 1 0 TIRELESS B.24 PAILWETEEINl VAUJE NfM PGL 0 M1iCIE5 1.7E L�OS'i- OTIf3N AREA S7 LAK INL'Ha2 Ad C N I 53VCK FEXM LO 'UNI JF1211fIK CONNSCOPE 6.24 STIFFENER TUBS E424 BNq'1RYw�969_S�G[:Ol�...I .I IA' � IY /044 Ni�11' 1 1r xw� jai 1+Af{. 4v4TlR YA41E NAL OIaN R INC 1.3 CR055�BECTION AREA W7E INC _ 2.B1 �IR/d:N J COLOR FOOT POMAN .16 NUANCE 6r24 SINGLE MODE X46- FLAME RESISTANT FILLERS 4 AWG COPPER CONROGATED CONDUCTOR X12 COPPER ARIAOR RIP CORD PVC: OUTER JACKET IM 4AYFrER VALJE NOMINAL C N !.L1 1.67 CROSS-SECTION A SOU N_E IHL'FIE3Y Y•04 JACKET CDLi74 I NL6CK WEiGHTR.INCAR FOOT UNDS -TR O Fd �, :2• r 6,24 9.24 HTSR7C TRU11K CRASS SECTION jIY.1�•K.ir ..*A. +• 1r riu nu 2 C.bM VwMer C.M. 1TN Ilornllrl DD C.f. Arr WNlbt W Tp.ID. 1yEJ1 ..T., On.b.A MAX ENTITLEMENT 110E 2.0 a awo ' b 12P .q1. Ln iA. NCO i=t 01pRr. CIN.wa.. ANMeP MabA I.IA Lag lEl IA.AMi 9W.A.TP 11 .IT T. rla mm • t55 Den aYjI OAM LSs L19 T.il IPb7e10aT E&u .fN 231 all 109 IaHL •_"AA110 I.10I Lli LLl lLsa1fa20[1T1 ii+147 h�.Rl L7! A ftmDL 4•m14Atq 1.14 LA?LL7 1P]7tlati].•L4 .1n 2ar. Adel lln ]liar 4 AWD 2SC w ISO• e1FM I.O4Y1 6>2A IAWD�Zll 1.16 2.41 Wo. P]Er "I m)6147. i 13 LE E 4AWO243 .4 143 .SON :'L2 72Ft17 7h: C.1.A- ls4 MAX 6"4AVW2..51 AS LLF6xI67E •d,31 Ah l4]d3 sfA 24 Aex6-4m mm4AVO .iE IS1x tlNi12 J'Mm1P.re nlan II 24507 ,W24 444 CWIL.r Er..tr.t-Ao e Lwtb N,1 Apt- AAIIA'A6 LE 2!1 2.10 3-l"%44 A-7. IMnYti DD r] 2 cw 4AYq 1.16 211 7.TP 3 .9 F 11 4A1P6 LFl 7.E1 2•Lv 1A2. o,24 Aw 13 b. n 14G Nwl a1244A1M1 ILTO ASi 11.53 1.99 Ul LAft 1 Cv f♦,lln IL45 14i .7i4AWG is &L3 13.46 tw1P•T2 .A-"t [6N24) PYBR(O TRUNK ENIITLEIAl:NI INFORMATION 46AIY N.Ts. 11' . 17' SCALE N.T.S. 3 HYBRID TRUNK INFORMATION (6X24) SCALE: N.T.S MANUFACTURER: NOKIA MODEL ABIP 475792A DIMENSIONS: 98"X 667'X 1433" (HX W X D) WEIGHT: 4 41 LBS L4m FINICnON CONNEOTOR 7YPE IADOMOKAL RF1 TO RF12 SFP56 ECMPo CFNtl I TO RADIO UNIB 14-W SIDE VEW ABIP DETAIL L SCALE: NIT S. mum IKlNIA - mm OND4 1110'dFIL Y114D PLI$ _ m7r x.� a9.11 41 Al i 7.13' N 7D.' as aAT 3 39614-AVHA B41 MASSIVE MIMO SCALE: N T S NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT SUPPLEMENTAL SHEET NUMBER: REVISION R-602 0 "AL AMERICAN TOWER* C O R P O R A T 1 0 N Mount Type 7 ft V-Frame ATC Asset Name HARD ROCK WI ATC Asset Number 311256 Engineering Number 15361603_C8_.01 Mount Elevation 229.5 ft Proposed Carrier ; T-Mobile Carrier Site Name Hayward WI-ATC 311256 Carrier Site Number AlN0947A Site Location 12454 North State Highway 27 Hayward, WI 54843-7319 46.083513,-91.513339 County Sawyer Date August 26, 2025 Max Usage 84% Analysis Result Contingent Pass Prepared By: Claire Chen Structural Engineer I Illtnl3y ••jgC OH.... %� tigHA K. y 45661 i1 B CARY No Esha`�'� ,; �aigadi MOdIate:2025J}8.27 U 1554:14 -04'00' ATCT—Servkm. I Fenton Main, Sutra 300-Cary, NC 27511.919.466.0112 Glib. 919.466,S4I4 Fax-xnnvameanntewecram ODA- 4069-11 Eng. Number 15361603 C8 01 August 26, 2025 A1w111CAN lowelw• Page 3 Introduction The purpose of this report is to summarize results of the mount analysis performed for T-Moblle at 229.5 ft. Supoortina Documents SpeciFicatinns Sheet: ALT 211fiR-7, dated May 18, 2018 Prol,lous All aly515: TEP Project 3l14907583 CS_01, dated October29, 2024 Hadla Frequency Data Sheet: RFDS ID NAIN0947A, dated July 25, 2025 nelerence Ilhntvs: Site photos from 2025 Analysis This mount was analyzed using American Tower Corporation's Mount Analysis Program and RISA-3D ➢asic Wlnd 5pead: 107mph 13-Serand Gust) ➢aalc WTndSFeed wJ lee: 54 mph 13-Second Gustl w/ 1.62" radial Ice concurrent Codes: ANSIjTIA-222.1 / 20151BC1 Wisconsin Commercial8ulldinH Code fkposureCatugory: C Al sir C a to go ry I u TapogmpW,, FMcr Pmm&re: Method 1 feature: flat Crest Halght (4); 0 ft Crest Length (L): 0 ft Spettral Respume: Sds=0,049. SdI =0.022 Site Mass; Default UL e L r ads; Lm = 500 1bs, Lv = 250 Ibs •IHe I—dryI rrdu1lnn N xenlbmao to eelwrnas VUR wnot be soluble Conclusion Based on the analysis results, the antenna mount meets the requirements per the applicable codes listed above provided the modifications listed below are completed: Install P2 (2.375a It 120") In mount pipe position 1 to be located 3" from left end of mount face looking out from tower. Connect with Site Pro 1 UB1212 (or approved equivalent) U-Bolts. No structural failures were addressed with the noted contingencies. Contingencies address Carrier's antenna spacing requirements. If you have any questions or require additional Information, please reach out to your American Tower contact. If you do not have an American Tower contact and have an Engineering question, please contact MountAnalysis@americantower.com. Please include the American Tower site name, site number, and engineering number In the subject line for any questions. MOUNT ANALYSIS ATCT—Spxhe-IFenton Maln,SUIN300-Cary,NC27511-919.465.0112OMce- 919.466.S414Fm- nww rksr"w cem NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. PLEASE REFERENCE THE MOUNT ANALYSIS REPORT FOR COMPLETE MOUNT ANALYSIS CALCULATIONS AND DETAILS. SUPPLEMENTAL PAGES INCLUDED IN THE CONSTRUCTION DRAWINGS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO VERIFY THEY HAVE THE MOST RECENT MOUNT ANALYSIS PRIOR TO CONTRUCTION, p n s7 iC L7 a U e 0 SUPPLEMENTAL SHEET NUMBER: REVISION R-603 0