Loading...
HomeMy WebLinkAbout010-841-30-4101-LUP-2025-356SITE NAME: DBS - HAYWARD EAST SITE ID: WIL03412 AT&TFA NUMBER: 10124042 USID: 96732 IWM JOB NUMBER: WSCHI0050477 10240 N. TOWER ROAD HAYWARD, WI 54843-6626 SAWYER COUNTY EXISTING 252' SELF SUPPORT ERICSSON NETWORK MODERNIZATION CIVIL WORK TO BE COMPLETED FIRST PER AT&T. NOKIA GROUND EQUIPMENT STAYS UNTIL ALL ERICSSON UP TOP IS DONE & INTEGRATION IS SUCCESSFUL. CONTRACTOR TO VERIFY TEMPORARY SOLUTION WITH CONSTRUCTION MANAGER PRIOR TO BEGINNING OF PROJECT. i a ; © THE PROPOSED PROJECT FOR THIS SITE INCLUDES: SCAN FOR DRIVING DRAWING INDEX PROJECT SUMMARY DIRECTIONS ' SHEET # SHEET DESCRIPTION REV. # TOWER OWNER: AMERICAN TOWER CORPORATION T-1 TITLE SHEET 1 ADDRESS: 10 PRESIDENTIAL WAY W AREA MAP LOCATION MAP OBURN, MA 01801 GN-1 GENERAL NOTES 1 CONTACT: ATC PM C-1 AERIAL MAP 1 PHONE: (781) 926-4500 C-2 SITE PLAN 1 cer' SITE ADDRESS: 10240 N- TOWER ROAD C-3 EQUIPMENT LAYOUT 1 HAYWARD, WI 54843-6626 C-4 TOWER ELEVATION PLAN 1 CUSTOMER/APPLICANT: AT&T WIRELESS WIL03412 C-4.1 ANTENNA AZIMUTH PLANS 1 95 W. ALGONQUIN ROAD DBS - C-5 EQUIPMENT DETAILS 1 ARLINGTON HEIGHTS, IL 60005 HAYWARD hall WIL03412 E-1 SITE DATA INPUT 1 NAD83 EAST DBS- RF-1 ANTENNA INFORMATION CHART & PLUMBING DIAGRAM 1 LATITUDE: 46° 00' 05,07" N ( 46.001408°) HAYWARD LONGITUDE: 91 ° 24' 21.77" W (91 406048°) EAST JURISDICTION: SAWYER COUNTY COUNTY: SAWYER n;e v GROUND ELEVATION: 1501'± AMSL � Rcc�C Lake OCCUPANCYTYPE: UNMANNED j A D-A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION Carer lake � Ha}r.-I•II Ar.d1 ® I:Co S:.: ra ;d:'_�c.Calr � fin' CONSTRUCTION TYPE: IIB 'lie GROUP: U A/E DOCUMENT REVIEW STATUS CODE COMPLIANCE NO SCALE NO SCALE wIMrA you W--t wr wr. mae wuce TITLE SIGNATURE DATE AT&T CONSTRUCTION III ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH AMENTUM PM: THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL PROJECT DESCRIPTION RF ENGINEER: GOVERNING AUTHORITIES, NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: ZONING APPROVAL: CODE TYPE CODE REMOVE SITE ACQUISITION: INSTALL • REMOVE (3) EXISTING SBNHH-1D65B ANTENNAS PROPERTY OWNER: W COMMERCIAL BUILDING CODE INSTALL (3) NEW NNHH-65C-R4 ANTENNAS . REMOVE (3) EXISTING SBNH-1D6565B ANTENNAS BUILDING IN LDING/DWELLING IBC 2015 • INSTALL (3) NEW AIR 6472 B77G B77M ANTENNAS • REMOVE (1) EXISTING BATTERY RACK STATUS CODE; STRUCTURAL IBC 2015 • 2017 INSTALL (9) NEW 10' ANTENNA MAST PIPE . REMOVE (1) EXISTING POWER PLANT 1 ACCEPTED: WITH OR NO COMMENTS, CONSTRUCTION MAY PROCEED ELECTRICAL NEC 01 MECHANICAL IBC • INSTALL (6) NEW RRH BACK TO BACK BRACKETS . REMOVE THE EXISTING NOKIA RADIOS INSTALL (6) NEW 10' RRHS MAST • REMOVE EXISTING ALU/NOKIA BBU EQUIPMENT AFTER CUTOVER 2 NOT ACCEPTED: RESOLVE COMMENTS AND RESUBMIT INSTALL (3) NEW 4494 B14/B29 RRHS IS COMPLETED ACCEPTANCE DOES NOT CONSTITUTE APPROVAL OF DESIGN, CALCULATIONS, CONTACT INFO. INSTALL (3) NEW 4472 RRHS ANALYSIS, TEST METHODS OF MATERIALS DEVELOPED OR SELECTED BY THE INSTALL (3) NEW 4890 B25/B66 RRHS RELOCATIONS SUBCONTRACTOR AND DOES NOT RELIEVE SUBCONTRACTOR FROM FULL INSTALL (1) NEW VERTIV 7100 W/ 58V POWER PLANT • RELOCATE (3) EXISTING NNH4-65C-R6 ANTENNAS COMPLIANCE WITH CONTRACTUAL OBLIGATIONS. A&E FIRM: AMENTUM AT&T • INSTALL (8) NEW RECTIFIERS IN THE NEW POWER PLANT • RELOCATE (12) EXISTING BATTERIES TO THE NEW POWER PLANT DIGITAL INFRASTRUCTURE, INC. CONSTRUCTION MANAGER: • INSTALL (7) NEW -58V CONVERTERS IN NEW THE POWER PLANT INSTALL ALL PROPOSED ERICSSON BBUS NOTE 2929 ARCH STREET, STE 1500 95 W ALGONQUIN, CALL DIGGERS HOTLINE CALL PHILADELPHIA, PA 19104 ARLINGTON HEIGHTS, IL • BEFORE ANY WORK IS TO BE COMPLETED THE UP TILT AND 0 SECTOR SAG NEEDS TO BE CORRECTED ON ALL SECTORS (800) 242-8511 CALL 3 WORKING DAYS CONTACT: MICHAEL STREET CONTACT: GWYN NOBLE BEFORE YOU DIG! PHONE: (315) 240 4776 PHONE: (847) 330-3467 4� amentum 2929 ARCH STREET, STE 1500 PHILADELPHIA, PA 19104 401110 AT&T N A/ �F.•G6.11 Q o cqc o Q O 1•��1j• � � � W w O 0 FI O <r! ✓Wv A� ICJ,--1 PROJECT NO: EP5TRFIL CHECKED BY: LS ISSUED FOR: CII DATE M C198CRIPTION 0 05/20/25 WIN FOR CONSTRUCTION 1 07/17/25 WW FOR CONSTRUCTION C 10 +IV,9'� rf V KARL R. �= KRA NA E-4 06 A Of till 111►'���t� IT A VIOLATION OF LAW FOR ANY PERSON, UN 5 THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET NUMBER: REVI510N: T_1 1 PROJECT COMPLIANCE NOTES: NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED WHERE USE OF METAL CONDUIT IS UNAVOIDABLE INSTALL PLASTIC LABEL ON THE METER CENTER TO SHOW "AT&T WIRELESS" (E.G., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 1. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR PROJECT GENERAL NOTES: SEWER SERVICE AND IS NOT FOR HUMAN HABITAT. ELECTRICAL INSTALLATION NOTES: (NO HANDICAP ACCESS IS REQUIRED). 2, OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES 1 FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: PERMONTH, BY AT&T TECHNICIANS. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL TURF VENDOR- AMENTUM DIGITAL INFRASTRUCTURE, INC. 3. NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS PROPOSAL, UNLESS DURING APPLICABLE LOCAL CODES CONTRACTOR- GENERAL CONTRACTOR (CONSTRUCTION) OWNER- EMERGENCY. CONDUIT ROUTINGS ARE SCHEMATIC. SUBCONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT AT&T OEM- ORIGINAL EQUIPMENT MANUFACTURER 4- OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED. BLOCKED. 5, ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO THE LATEST AT&T SYSTEM GROUNDING STANDARDS. "TECHNICAL SPECIFICATION FOR WIRING, RACEWAY & SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE CONSTRUCTION OF LTE SITES AND WILL FOLLOW AT&T GROUNDING AND BONDING ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE REQUIREMENTS FOR NETWORK FACILITIES AT&T DOC ID ATT-TP-76416 AND AT&T POLICY ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. BROUGHT TO THE ATTENTION OF CONTRACTOR. LETTER ATT-CEM-13002. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED DURING CABLES SHALL NOT BE ROUTED THROUGH LADDER -STYLE CABLE TRAY RUNGS 3, ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CONSTRUCTION OPERATION. CODES, REGULATIONS AND ORDINANCES, SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES 7. THE CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I.E., HOTS), GROUNDING AND T1 CONDUCTOR AND CABLE SHALL AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY B- INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM DRAWINGS PROVIDED BY BE LABELED WITH PROPER LABELING ID, 145 TYPE FIBER TAG, WITH UV RATED P-TOUCH LABEL, MINIMUM WIDTH OF 1/2" THE PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK ALL WORK CARRIED OUT SHALL THE APPLICANT REPRESENTATIVE. THE CONTRACTOR SHALL NOTIFY TURF VENDOR OF ANY IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH PLASTIC TAPE PER COLOR SCHEDULE. ALL EQUIPMENT 9, NO ADDITIONAL PARKING IS PROPOSED. EXISTING ACCESS AND PARKING WILL BE USED, SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY 4. DRAWINGS PROVIDED HERE ARE NOT TO SCALE AND ARE INTENDED TO SHOW OUTLINE ONLY, 10. NO ADDITIONAL LANDSCAPING IS PROPOSED AT THIS SITE. RATING AND BRANCH CIRCUIT ID NUMBERS (I.E. PANEL BOARD AND CIRCUIT ID-S), 11. ALL COAXIAL CABLE/FIBER AND DC CABLE INSTALLATION IS TO FOLLOW MANUFACTURER'S 5 UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, INSTRUCTION. PANEL BOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE CLEARLY LABELED WITH APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE P-TOUCH LABELS ON 145 TYPE FIBER TAGS. DRAWINGS GREENFIELD GROUNDING NOTES: THERE SHALL BE NO USE OF NYLON TIE CABLE FOR INDOOR USE, 6. "KITTING LIST" SUPPLIED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT WILL BE SUPPLIED BY TURF VENDOR. ITEMS NOT INCLUDED IN THE BILL OF MATERIALS AND KITTING LIST SHALL BE SUPPLIED BY ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER, CONTROL AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (#14 AWG OR THE CONTRACTOR POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING LARGER), 600 V. OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90- C (WET & DRY) CONDUCTORS IN ACCORDANCE WITH THE NEC AND AT&T GROUNDING AND BONDING REQUIREMENTS FOR OPERATION LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED UNLESS OTHERWISE SPECIFIED 7• THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH NETWORK FACILITIES ATT-TP-76416 AND AT&T POLICY LETTER ATT-CEM-13002, MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (#2 TIN STRANDED OR THE SUBCONTRACTOR SHALL PERFORM IEEE FALL -OF -POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE LARGER), 600V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION CLASS B STRANDED COPPER CABLE RATED FOR 90- C B. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE SUBCONTRACTOR SHALL FURNISH AND INSTALL (WET AND DRY) OPERATION LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED UNLESS OTHERWISE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE TURF SUPPLEMENTAL GROUND ELECTRODES AS NEEDEDTO ACHIEVE A TEST RESULT OF OHMS OR LESS SPECIFIED VENDOR, THE SUBCONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (#14 AWG OR 9• CONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90° C (WET AND DRY) CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWINGS - THE CONDUIT AND PROVIDE TESTING RESULTS, OPERATION WITH OUTER JACKET LISTED OR LABELED FOR THE LOCATION USED UNLESS OTHERWISE SPECIFIED. 10 THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND STRUCTURES ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH MINIMUM #2 AWG COPPER WIRE UL AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 75" C (90° C IF AVAILABLE) SATISFACTION OF OWNER. APPROVED GROUNDING TYPE CONDUIT CLAMPS. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE 11 CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR TIN AND NEC. CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY ANTENNAS REMOVED SHALL BE STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E. RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 60 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS 12- CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. EACH CABINET AND FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #2 TIN STRANDED COPPER FOR INDOOR/ROOFTOP ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT) OR RIGID NONMETALLIC CONDUIT (RIGID PVC, 13 CONSTRUCTION SHALL COMPLY WITH AT&T AND MANUFACTURER SPECIFICATIONS. APPLICATIONS; #2 AWG SOLID TINNED COPPER FOR OUTDOOR GROUND CABINETS, SCHEDULE 40) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS, 14. ALL ITEMS REMOVED FROM SERVICE ON SITES THAT HAVE AN AT&T ASSET TAG MUST BE LOGGED CONNECTIONS TO THE GROUND BAR SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) SHALL BE USED FOR OUTDOOR LOCATIONS ABOVE GRADE. BACK IN WITH AT&T ON OPPOSITE SIDE OF THE GROUND BAR ARE PERMITTED, ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE RIGID NONMETALLIC CONDUIT (I E. RIGID PVC SCHEDULE E R RIGID PVC SCHEDULE 60) SHALL BE USED UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED CONCRETE IN AREAS OF D A tv]TI�T/'� C 1J NOT SCALE 1J1�L"1 W 11�1 lIJ D O NOT SCALE DRAWINGS (2) CONDUCTORS OF #2 AWG SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. HEAVY VEHICLE TRAFFIC. ALL DRAWINGS CONTAINED HEREIN USE OF 90'BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION ARE FORMATTED FOR 11x17. ADEQUATELY SUPPORTED OCCURS OR FLEXIBILITY IS NEEDED. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED SET SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING SCREW FITTINGS ARE NOT ACCEPTABLE. OF ANY DISCREPANCIES BEFORE PROCEEDING WITH ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS THE WORK OR BE RESPONSIBLE FOR SAME. CRIMPS; A MINIMUM OF (2) CRIMPS AND WINDOWLESS LUGS FOR OUTDOOR APPLICATIONS AND WINDOWED CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND I LUGS FOR INDOOR APPLICATIONS. NEC, ABBREVIATIONS AND SYMBOLS: ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE WIREWAYS SHALL BE EPDXY -COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS; GROUNDING RING. SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) ABBREVIATIONS: SYMBOLS: APPROVED ANTIOXIDANT COATINGS (I.E. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET AGL ABOVE GRADE LEVEL F-S-/-G-1 SOLID GROUND BUS BAR STEEL SHALL MEET OR EXCEED UL 50 AND RATED NEMA 1 (OR BETTER) INDOORS OR NEMA 3R (OR BETTER) OUTDOORS. BTS BASE TRANSCEIVER STATION ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL, METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET (E) MIN, EXISTING F_S/N_j SOLID NEUTRAL BUS BAR MINIMUM MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA 1 (OR BETTER) INDOORS OR WEATHER PROTECTED (WP OR BETTER) N,T,S, NOT TO SCALE SUPPLEMENTAL GROUND CONDUCTOR TO THE GROUND RING, IN ACCORDANCE WITH THE NEC AND AT&T GROUNDING AND BONDING REQUIREMENTS OUTDOORS, REF REFERENCE FOR NETWORK FACILITIES ATT-TP-76416 AND AT&T POLICY LETTER ATT-CEM-13002, NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) RF RADIO FREQUENCY 2-POLE THERMAL -MAGNETIC CIRCUIT T.B.D. TO BE DETERMINED BREAKER BOND ALL METALLIC OBJECTS WITHIN 6 OF MAIN GROUND WIRES WITH NDOORS OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. T. B.R. TO BE RESOLVED 1�t2 AWG TIN-PLATED COPPER GROUND CONDUCTOR. THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR BEFORE TYP REQ TYPICAL o^ SINGLE -POLE THERMAL -MAGNETIC REQUIRED CIRCUIT BREAKER GROUNDS FOR INDOOR SITE EQUIPMENT SHALL BE LANDED ON THE APPROPRIATE SECTION OF THE CRGB OR COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. EGR EQUIPMENT GROUND RING HALO AS PER ATT-TP-76416 AND AT&T POLICY LETTER ATT-CEM-13002, THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN AWG AMERICAN WIRE GAUGE e CHEMICAL GROUND ROD MGB MASTER GROUND BAR GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD AGAINST LIFE AND PROPERTY. EG EQUIPMENT GROUND ® TEST WELL ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC BCW BARE COPPER WIRE CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS, WHEN IT IS REQUIRED TO BE SIAD SMART INTEGRATED ACCESS DEVICE C::H DISCONNECT SWITCH HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, GEN GENERATOR IGR INTERIOR GROUND RING (HALO) ❑® METER RIBS RADIO BASE STATION A amentum 2929 ARCH STREET, STE 1500 PHILADELPHIA, PA 19104 ' AT&T N PF�I Q o 00 Ln c� w A F�41 PROJECT NO: EPSTRFIL CHECKED BY: LS ISSUED FOR: FtFV DATE R DESCR3PTION 0 05/20/25 WW FOR CONSTRUCTION 1 07/17/25 WW FOR CONSTRUCTION _[,�,,��j1111I I I I I111►sI�I.} I KARL R. KRA NA �� �rylLlllll�t111ttttt'`i �•'I7/25 IT A VIOLATION OF LAW FOR ANY PERSON, GM. $5 THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT, SHEET NUMBER: IREVISI GN-11 1 GENERALNOTES I I 1 ■ ice' `, • � Now 99 II L� CENTI ANTE •� ALF •.I[ �• - SECT( f • _ m Of 0 O � zo ti lk 1 `•�- �' �• �, T: �•� .lye �7' r' rV` �:-•.Y• a �i _ ii. w *e��r��yw'r•• ti . kk S p+ 4. +' *� C4 sEL (1) EXISTING SBNH-1D6565B ANTENNA TO BE REMOVED (TYP. PER SECTOR) Al C3 r • I. � t C /2 (1) EXISTING SBNHH-1D65B ANTENNA TO BE REMOVED (TYP. PER SECTOR) Cl (GAMMA) 2700 AZIMUTH - (1) EXISTING NNH4-65C-R6 ANTENNA TO BE RELOCATED TO POS 3 (TYP. PER SECTOR) ALL EXISTING RRHS & ASSOCIATED MOUNTING HARDWARE TO BE REMOVED (TYP. ALL SECTORS) NOTE: ALL DIPLEXERS/TMA'S & ASSOCIATED MOUNTING HARDWARE TO BE REMOVED. (ALPHA) 30° AZIMUTH A2 A3 A4 r, (1) EXISTING DC-6 SURGE ARRESTOR TO REMAIN (TYP OF 3) NOTE: INSTALL PROPOSED EQUIPMENT MOUNTED PER MOUNT STRUCTURAL ANALYSIS REPORT BY AMENTUM DIGITAL INFRASTRUCTURE, INC DATED 05/12125. REFER TO REPORT FOR ADDITIONAL REQUIREMENTS. NOTES: ALLSTRUCTURAL WORK IS TO BE COMPLETED PRIOR TO RF WORK STARTING. CONTRACTOR TO ENSURE THAT THERE IS NO ANTENNA SKEW. NOTE. FOR THE INSTALLATION OF THE RRHS, INSTALL NEW 2.0 STD (2.375" OD) x 120" LONG RRH PIPES WITH CROSSOVER BRACKETS (SITEPR01 PART NO. SCX1-K OR APPROVED EQUIVALENT. MOUNTED ON NEW COMMSCOPE RR-FA2 RRH MOUNTING BRACKET OR APPROVED EQUIVALENT. DO NOT EXCEED MOUNTING MORE THAN 2 RRH's / 1 SURGE PER PIPE. NOTE: FOR THE INSTALLATION OF THE ANTENNA, INSTALL NEW 2.5 STD (2.875" OD) x 120" LONG RRH PIPES W/ CROSSOVER BRACKETS (SITE PR PART# SCX2-K, OR APPROVED EQUIVALENT). NOTE: THE EXISTING BRACKETS INSTALLED TO THE TOWER LEGS FOR THE SECTOR FRAMES ARE NOT INSTALLED IN LINE WITH EACH OTHER CAUSING THE SECTOR SAG. THE BRACKETS WILL NEED TO BE TURNED TO BE IN LINE WITH EACH OTHER TO CORRECT THE SAG IN ALL SECTORS. (ALPHA) 30° AZIMUTH Al f A2 A3 (1) EXISTING DC-6 SURGE' ROTATE EXISTING SECTOR ARRESTOR (TYP OF 3) MOUNTS TO ACHIEVE FINAL ` A4 AZIMUTH INSTALL (1) NEW 4494 B14/B29 RRH & C4 (1) NEW 4890 B25IB66 RRH (TYP PER SECTOR) (1) EXISTING NNH4-65C-R6 ANTENNA 7 I RELOCATED FROM POS 1 (TYP PER SECTOR) C3 4 B1 (GAMMA) 270° AZIMUTH B2 __C2 S B3 INSTALL (1) NEW AIR6472 B77G B77M (TYP PER SECTOR) �r \ INSTALL (1) NEW 4472 RRH (BF in,) 1 (TYP PER SECTOR) Cl 64 150° A::Ir.IUTH INSTALL (1) NEW NNHH-65C-R4 ANTENNA (TYP PER SECTOR) N Wa I s 0' 1' 2' 4' 8' B1 �r B2 ..B3e� 0\.Q 5vC Le�RgE.�AG`�yQl O J� (BETA) 150° AZIMUTH 0' r 2' 4' e' A amentum 2929 ARCH STREET, STE 1500 PHILADELPHIA, PA 19104 AT&T A% N cV� �F.•GG�i -+y � � O � M 00 �D c-� ITI O �w ✓Wv A�F,4] PROJECT NO: EP5TRFIL CHECKED BY: LS ISSUED FOR: iEY DATE OWMIDESCRIPTION 0 05/20/25 WW FOR CONSTRUCTION 1 07/17/25 WIN FOR CONSTRUCTION lY. KARL R. `KRAT�NA E-4�pa6 A C'�h�TM ,, / ATNY E,R ION I Nyr U' OF LI{T NSED PRRO E SOCUM NTGDINEER?ION I ITHIS D EXISTING ANTENNA AZIMUTH PLAN 11"x17"SCALE: /8" =1-0.1 I PROPOSED ANTENNA AZIMUTH PLAN 22"x34" SCALE: 3/8" = 1'-0" 11 "xl7" SCALE: 3/16" = 1'-0" I 22"x34" SCALE: 3/8" =1'-0" SHEET NUMBER: REYISIOIV 1� C-4.11 1 !�j MOUNT ANTENNA IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED PROCEDURE DETAIL FOR MOUNTING PURPOSES ONLY. NOT ALL MEMBERS SHOWN ANTENNA MOUNTING DETAIL EXISTING SURGE PROTECTOR "SQUID" PROPOS MOUNT ASE APPROVED E( EXISTING V-F PROPOSED DUAL RRH BRACKET EXISTING V-FRAME ARM PROPOSED SCX1-K MOUNT OR APPROVED EQUIVALENT KISTING PIPE MOUNT MOUNT BRACKETS INSTALL PER MFG. SPECS. ROPOSED ANTENNA SED JUMPER CONNECTION, (TYP) Z±-\��r A i IN MIN. BEND RADIUS, NUFACTURER'S SPECIFICATIONS SCALE: NTS 1 COMMSCOPE RR-FA2 --'-3ED PIPES A 18" - -13.56" 7 6 K 700 (TORQUE BOLTS TO 60FT/LBS (TYP) AFTER INSTALLATION) PARTS LIST ITEM QTY PART NO. PART DESCRIPTION LENGTH UNIT WT. NET WT. 1 1 SCX1 CROSSOVER PLATE 3,71 3.71 2 4 X-UB1212 1/2" X 2-1/2" X 4-1/2" X 2" U-BOLT (HDG.) 0.63 2.50 3 8 G12FW 1/2" HDG USS FLATWASHER 0.03 0.27 4 6 G12LW 1/2" HDG LOCKWASHER 0.01 0,11 5 8 1 G12NUT 1/2" HDG HEAVY 2H HEX NUT 0.07 0.57 A _ TOTAL WT. # 7.16 2-3/8" O.D ANTENNA PIPE (ORDERED SEPARATELY) PROPOSED RRHs I SITEPR01 SCX1-K � PROPOSED C!L OF Cam' 8 NTENNA r2-3/8" O,D. ANTENNA PIPE (ORDERED SEPARATELY) I RRH DUAL MOUNT BRACKET ITEM PART NO. DESCRIPTION QTY. 1 MTC378912 WELDED FRONT BRACKET 2 2 MTC378909 RRU HANGER 4 3 MTC378903 REAR BRACKET 2 4 GWF-04 1/2" GALV FLAT WASHER 8 5 GB-04145 1/2" X 1-1/2" GALV BOLT KIT 8 6 1 GWL-04 1/2" GALV LOCK WASHER 12 7 GN-04 1/2" GALV HEX NUT 12 8 MT-379 1/2" X 12" GALV THREADED ROD a 9 RRFA-0001-00 BRACKET, RRU MOUNT SMALL STABILIZER 2 10 RRFA-0002-00 BRACKET, RRU MOUNT LARGE STABILIZER 2 11 I GWF-03 3/8" GALV FLAT WASHER 8 12 GWL-03 3/8" GALV LOCK WASHER 8 13 GN-03 3/8" GALV HEX NUT 8 14 MTC8196 3/8 X 1-114" Carriage Bolt 8 �, SCALE: NTS 1 2 PARTS LIST ITEM QTY PART NO. PART DESCRIPTION LENGTH 1 1 1 1 SCX2 CROSSOVER PLATE 7in 2 1 2 X-UB1300 1/2" X 3" X 5" X 2" U-BOLT (HDG.) 3 8 G12FW 1/2" HDG USS FLATWASHER 4 8 G12LW 1/2" HDG LOCKWASHER 5 8 G12NUT 1/2" HDG HEAVY 2H HEX NUT 6 2 X-UB1212 1/2" X 2-1/2" X 4-1/2" X 2" U-BOLT (HDG.) 2-7/8" O.D. ANTENNA PIPE (ORDERED SEPARATELY) y 3 4 5 SCALE: NTS 1 3 1 SITEPR01 SCX2-K PROPOSED PIPE MOUNT PROPOSED ANTENNA (AIR6472 B77G B77M) ANTENNA BRACKET. INSTALL PER MFG. SPECS. (AS NEEDED) PROPOSED JUMPER CONNECTION, MOUNT ANTENNA IN ACCORDANCE WITH (TYP) MAINTAIN MIN. BEND RADIUS, MANUFACTURER'S RECOMMENDED PER MANUFACTURER'S PROCEDURE SPECIFICATIONS DETAIL FOR MOUNTING PURPOSES ONLY. NOT ALL PLATFORM MEMBERS SHOWN SURGE PROTECTOR & RRHS LAYOUT I SCALE: NTS 1 5 AIR ANTENNA MOUNTING DETAIL I SCALE: NTS 1 6 1 NOT USED UNIT WT NET WT. 4.80 4.80 0.66 1.31 0.03 0.27 0.01 0.11 0.07 0.57 0.63 1 25 TOTAL WT. # 8.39 2-318" O.D ANTENNA PIPE (ORDERED SEPARATELY) SCALE: NTS 1 4 SCALE: NTS 1 7 A amentum 2929 ARCH STREET, STE 1500 PHILADELPHIA, PA 19104 Lrf:-10 H QN v O o G w cn CD z �w O � (n IPROJECT O CHECKED B: EPSTRF LS ISSUED FOR: RFVI DATE p DESCRIPTION 0 05/20/25 WW FORCONSTRUCTION 1 07/17/25 WW FOR CONSTRUCTION *�5„ ... ��� r KARL R. * K RA NA ro E -47606 ��►►► 111 I r ����N�l OI•` 17�25 K A VIOLATION OF LAW FOR ANV PERSON, (INI. 3 THEV ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET NUMBER: REVISION: C-5 1 1 STEP R: EKf M DC PLANT TYPE TROAt UROP-DOWN MENU: -. em4W OCP1.5r.r re`I':-;=LE.TLL FDF"W 4ANVi.ic 0flit D1 PLANT) V.r11.ATV -OVDC IMSurr 1100 OINOI IMAr IaV CONY �ev.Pmlwuer x PLANrePEDIFUD _ L_.....WVONF--�.-.—_._.—.__...__._.__-'— _...._.._ ....._. {[TC jKilVrf; ONFq;Uli4TIQN CAN BE REVIEW EO ON Di, PLAyr WI1R4S11FE TI STEP7/- THISSTEP LV SHOWN IF`OENE -DC PLANT rLWr TYPE NM REEK SELECTEP- --- - fiiT]k: TTtfB aTEP:DRLVaHDWN IFTTCO GPS2424 OC PLANT PLANT TYPE HAS BEEN36LE4tED: STEPS: DO YOU VLWi T6CMerIGUREASIAX3ARD 6UWDALDNE nC GOf1VER7Hl 5Y[7F'MT N NOTTrr', IF YOU SELECT'Y' ANY INTEGRATED GC PLANT _in r%ERTEROPTLOKU WILL EE B'PA53ED .TEP4: FNTgR WDOOR SITE6UILWN4aHELTER DATA {SgVyrd 7oou94 Pdsd IarinlFrlRr AC IIOM(0q L.QAII w,x.ywR SELECT SITE ENCLOSURE TYPE & 2NZF_t 1i' S'. TO•STTELTER SPECIFY ININVItDUAL cgwIrV UGHI7cWLR:. HVAC E _ aP ECIFY 1NOIVU]UAL Cc011ng UMTlGNTLR: SPECIFY TNIHWDUAL CJfOTgle UWMN TLR-- 5PECIFY ININVMUALCiwllny UNITICNTLR: SPECIFY IN01VN1uAL Ce ,!m URITrCNTLR: SPECIFY (NAIVK7VAL Cpatmq uftlmCNTLR: ARE THERE SITE HVAC HEATING UNITS?� TOTAL SPECIFIED SITE HVAC: 10.TONS ESTIMATED HVAC REQUIREMENT T•TONS COW.IHO TF NexlGen, with-Gan-Conlr.1 IS SELECTED USER NEEDS TO VERIFY GENERATOR RUN ALARM IS WIRED THROUGH SMART CONTROLLER. OC LOADS FOR SHELTER ENVIROMENTAL SYSTEMS ARE AUTOMATICLY ADDED TO THE DC PLANT LOAD STEP 6: £MEP SITE STATPONALY QEUERAIOR DAi1L DOES SITE HAVE A STATIONARY 6ERERATORT Y AC or tlC. AC DENERAT�t Sim Km 62 E91 VAATED CAPACITY REQUIRED: li KW 61111 CAPACITY SUF FIDIENY EN1 ER SITE BATTERT CDNFKWHATION DATA; AELECr BINDLE STRING BATTERY CAPACITY SAIII: 190 SPECIFY TOTAL QUANTITY OF BATTERY STRINGS- 3 TOTAL SITE BATTERY CAPACITY IAHI: 570 NOTI.¢rANDARD BATTERY CAPACITY KU aFSN SPECIFW0 Wl L I� Veh:I V�f.t'4111Yx Fi.l 1.0IFi - J d�l:er.• yrr •+-`! Stria ESTIMATED BATTERY RESERVE TME. 3 77 11g11RS _{9IT¢ GENSEI] 1 -SITE WITH STATIONARY GENSETS Elp,po:dhdhVIN., CC PIa,11(NEC)2OC68)eOpp.d null 200 a,rp Ballerr d,scornacl Neakwr s hall:ecei•:a no ar..ah_r i' 2 A" aI 160 AH ballerei All olhar ix.�,ions with leg;,cy OC,Paris Ilypirally equipped ,r th ba:lary di,,- ,n.cl breaker: ,206 amFS) shad rec.,ve n. gre,+ler Ihdn sh eh,.s of 1 d0 AH to ll.A.s ALL SITES WITHOUT A STATIOINARY GENSET . SnAO Ce 4ee}xred•tl rQ.4 h", d5a•Ivryle _ ANY QUESTIONS PLEASE CONTACT RICK BADGERO (RB66209?ATT COM) SITE DATA INPUT SITE POWER •24VDC EQUIPMENT LOAD: 0 WATTS _ i6VDC EQUIPMENT LOAD: 647 WATTS i .5BVDC EQUIPMENT LOAD: 10788 WATTS 0 AMPS at *24V 12 AMPS aldBV 1B6 AMPS at-SBV NO SECOADAIIY SEV LOADS-pC GDMYMRMR SYSTEM HOT REWIRED TOTAL PRIMARY 45V LOAD: 11194 1YATT5 00E MIPS AI.4TV DO PLANT Vnlrr STO•FyyDC MaN6wF�1100 PIAFIT 100VA►511 V CONY •aAV RECTIFERS REfl6RRED IN•1]; B -40V RECT(FIFR 6LOT5: 17 CVKV. TY3•E: UNIVERSAL Ta GLO.RIOM 3J MCT SLOTS43HELF CAN OE —COW USED FOR CO -56V CONVERTERS REMM ED{Nrt}: T -56V SLUTS: E ESTIMATED S4TTP�1' R£8F11yE iIYE 3 14 AH 46V STRING$ =r 0.0! NQURS MO-SITC OENERATORt LTE 4G A AdLLAty EQUIP MEN 0 Eressan LTE IRBSb601 BBU - 1 DUL 4T 0 0 EhuOD LT�F Rl39[GhF'88u_7 UUL 48 0 0 E,;ss WiCDNIA Rallool_1 DIM dR 0 0 Ericsson LTE RBS660I BBU -1DUS 4! 0 0 PrI —D tTE FTR:,&Q$BWt •2M 46 0 0 Ericsson %l,IU 46 0 0 E,cs nL7EFMB 5216 46 0 0 P614 PIAI Gard 41 0 0 6630 BBU Card 4E 1 0 0 16648 BBU Card 46 0 5 16675 BBU Card 46 0 0 6651 BBU Card da 0 0 6573 RuIU a 4; 0 0 6674 BBU Cant 4L 0 1 166 lO Sde Cpnl,vller 4S 6 'r•S7Y YB11 Corr) 46 315 6TY r tlul R�Ip HFad. v0t.v9 wAtt! a 5 T I OUT IRRU 4690 1921195-966 L54 3027 3 I OUT JIUNJ u44 014, 1-29 St 2085 _ 3 OUT JAIR 0472 8770. B77M yF ]71y 0 FYI I! 4�A 6 a a 6 0 46 0 0 I 46 0 0 do 0 0 40 0 R 40 0 0 46 6 0 48 0 0 All 6 0 N 0 0 1. 0 0 46 0 0 0 0 0 A 0 0 I 48 0 0 41 0 7 f 46 5 6 4E R �o 00 I• �o Q �0 o� mo o� o� o0 Q� as o0 ESTIAIATEP SITE MAY, AC LOAD IAKPSI 166,17 AMPS ES TIMATE 200A SERVICE SUFFICIENT ESTIMATED CAPACITY REWIRED: 34 KW ` ON SITE AC GENERATOR CAPACITY: 50 KW ESTIMATE GENSET CAPACITY SUFFICIENT RECOMMENDED ENVFRQSY$TEM- 2•TOKSGQOLRIO - SPECRIlru ENVIROMEN I'AL Sy !FTL M.1 10.TON3 ESTIMATE SUF MOUNT MAC CAPACIT V 90 WWI 120 Wail SCALE: NTS 1 1 4� amentum 2929 ARCH STREET, STE 1500 PHILADELPHIA, PA 19104 AT&T � O M oo 1� rJ W vIMJ1 C !� r-I F1-1 ✓ Y PROJECT NO: EP5TRFIL CHECKED BY: LS ISSUED FOR: EV DATE R bEKRIPT1Oti 0 05/20/25 WN FOR CONSTRUCTION 1 07/17/25 WW FO:R CONSTRUCTION KARL R. KRA NA E-4 66 f A OKW I :: R A VIOLATION OF LAW FOR ANY PERSON, IL BB THEY ARE ACTING UNDER THE DI RECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET NUMBER: REVISIC E-1 1 ANTENNA ANTENNA ANTENNA ANTENNA TMAS, RRH's, DIPS DC SURGE/DISTRIBUTION & NUMBER MODEL VENDOR AZIMUTH CENTERLINE COAX/DC/FIBER FROM GROUND MODEL NNHH-65C-R4 Al (96"M9.6"x7.8") COMMSCOPE 30' 205'-0" (1)4472 (99.2 LBS) AIR 6472 B77G B77M A2 (36.4"xl6X'x7.5") ERICSSON 300 205'-0" RRH's INTEGRATED INTO (92.6 LBS) ANTENNAS NNH4-65C-R6 A3 (96"x19 6"x7 8") COMMSCOPE 30' 205'-0" (1) 4494 B14/B29 (2) RAYCAP DC6-48-60-18-8F (102 1 LBS) (1) 4890 1325/1366 (1) RAYCAP DC6-48-60-0-8C (2) CONTROL CABLE/POWER NNHH-65C-R4 DIAMETER: 0.78" (19.7 MM) CABLE 89 (96"xl9.6"x7.8") COMMSCOPE 150° 205'-0" (1) 4472 (#8 AWG DC TRUNKS) (99.2 LBS) (4) CONTROL CABLE/POWER DIAMETER: 0.92" (23-4 MM) CABLE - AIR 6472 B77G B77M (#6 AWG DC TRUNKS) B2 (36.4"M6.1"x7.5") ERICSSON 150° 205'-0" RRH's INTEGRATED INTO (92.6 LBS) ANTENNAS (1) FIBER/HYBRID DIAMETER: 0.39" (10 MM) FIBER - (12 PAIR FIBER TRUNKS) NNH4-65C-R6 B3 (96"xl9.6"x7 8") COMMSCOPE 1500 205'-0" (1) 4494 B14/B29 (102 1 LBS) (1) 4890 B25/B66 DIAMETER: 0.39" (10 MM) FIBER - (18 PAIR FIBER TRUNKS) NNHH-65C-R4 (12) 1-5/8" COAX G1 (96"M9.6"x7.8') COMMSCOPE 270' 205'-0" (1)4472 @280't (99.2 LBS) AIR 6472 B77G B77M G2 (36.4"xl 6.1 "x7.5") ERICSSON 270' 205'-0" RRH's INTEGRATED INTO (92.6 LBS) ANTENNAS NNH4-65C-R6 G3 (96"xl9,6"x7.8") COMMSCOPE 270' 205'-0" (1) 4494 B14/B29 (102.1 LBS) (1) 4890 B25/B66 NOTES: 1. VERIFY ANTENNA DIMENSIONS WITH MANUFACTURER. 2. VERIFY FINAL ANTENNA MODEL WITH CURRENT VERSION OF THE AT&T RFDS I ANTENNA INFORMATION CHART Sector A Al A A SCALE: NTS I 1 I PLUMBING DIAGRAM (TYP PER SECTOR) SCALE: NTS 1 2 A amentum 2929 ARCH STREET, STE 1500 PHILADELPHIA, PA 19104 AT&T a M� O� H O � O ✓ � w M Aa-ti IIJ,--I� W UL I CHECKD BO : EP5TRFLS I I ISSUED FOR: DATE R 9ESCRIPTION 0 05/20/25 WWI FOR CONSTRUCTION 1 07/17/25 WW FOR CONSTRUCTION N ���i'<tlw� �5 ................° KARL R. KRATNA E-4,7[l05 rm It A VIOLATION OF LAW FOR ANY PERSON, IJH� THEV ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET NUMBER: RMSIC RF-1 1 Sector B B1 132 ioaewz� AwvxsIwazA B3 7roaas M AwsrramC.. �r BSO I I 100 —AwS Hafc vtar� . �I 1 PLUMBING DIAGRAM (BETA & GAMMA SECTOR) SCALE: NTS 1 NOT USED SCALE: NTS 2 4�� amentum 2929 ARCH STREET, STE 1500 PHILADELPHIA, PA 19104 e� AT&T N � 0 M L Ln �J � ♦ w H � o H o�A � W PROJECT NO: EP5TRFIL CHECKED BY: LS ISSUED FOR: REV DATE AWN Or--r EtIFMON 0 05/20/25 WW FOR CONSTRUCTION 1 07/17/25 WW FOR CONSTRUCTION \ ►1CC+1++/V'q/�i ti �\\\�l �s ............. KARL R. KRATJNA E-4 06 A C31HI::�= IT A VIDLATIQN OF LAW FOR ANY PERSON, UH THEYARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET NUMBER: REV1S1 FT-2 1