Loading...
HomeMy WebLinkAbout024-741-29-4301-LUP-2025-216R nd N 1 K Lake Little Rvun &v_gd mew VICINITY MAP COMPLIANCE CODE ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 2015 IBC NATIONAL ELECTRICAL CODE (NFPA 70, NEC 2017 W/ AMND) 2015 WISCONSIN MECHANICAL CODE (IMC 2015 W/ AMND) 2018 WISCONSIN UNIFORM PLUMBING CODE (UPC) 2015 WISCONSIN ENERGY CONSERVATION CODE (IECC 2015 W/ AMND) 2015 WISCONSIN FIRE CODE (IFC 2015 W/ AMND) WISCONSIN COMMERCIAL BUILDING CODE WISCONSIN UNIFORM DWELLING CODE (UDC) 2015 WISCONSIN FUEL GAS CODE (IFGC 2015 W/ AMND) UTILITY COMPANIES AMEMCAN TOWERO ATC SITE NAME: ROUND LAKE WI ATC SITE NUMBER: 211543 T-MOBILE SITE NAME: Al N0963A T-MOBILE SITE NUMBER: Al N0963A SITE ADDRESS: 11556W LAWRY ROAD HAYWARD,WI 54843 SITE CLASS: GUYED PROJECT SUMMARY SITE ADDRESS: 11556W LAWRY ROAD HAYWARD,WI 54843 COUNTY: SAWYER GEOGRAPHIC COORDINATES: LATITUDE: 45.99848102 45" 59' 54.532' N LONGITUDE:-91.27044478 91"16'13.601"W GROUND ELEVATION: 1427' AMSL PROJECT TEAM TOWER OWNER: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ENGINEER: ATC TOWER SERVICES LLC 1 FENTON MAIN, STE 300 CARY, NC 27511 POWER COMPANY: JUMP RIVER ELEC COOP PROPERTY OWNER: PHONE: 800-273-5111 TOWN OF ROUND LAKE TELEPHONE COMPANY: UNKNOWN 11556W LAWRY ROAD PHONE: N/A HAYWARD,WI54843 ayn CSMIlod-l-ft T-MOBILE MICROWAVE PLAN APPLICANT: T-MOBILE CENTRAL LLC ATTN: BILAL BATROUKH 1400 OPUS PLACE DOWNERS GROVE, IL 60515 PROJECT DESCRIPTION THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED AND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW: TOWER WORK REMOVE (2)1.8' FIBER CABLE(s) INSTALL MOUNT MO D I FICA T IONS, (1) DISH(s), (1) OD U (s), (2) 2.00" HYBRID, (1) 0.63" CONTROL CABLE, AND (1) 0.39" FIBER TRUNK CABLE(s) EXISTING (6) ANTENNA(s), (6) RRU(s) TO REMAIN GROUND WORK INSTALL (1) IDU PROJECT NOTES 1. THE FACILITY IS UNMANNED. 2. A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE. 3. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE. 4. NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSAL IS REQUIRED. 5. HANDICAP ACCESS IS NOT REQUIRED. 6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U.S.C. § 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THAT INVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDER CFR § 1.61000 (13)(7). PROJECT LOCATION DIRECTIONS HEAD NORTH ON 1-35 N, TAKE EXIT 183 FOR MN-48 TOWARD CNTY 61/HINCKLEY, 0.2 MI. TURN RIGHT ONTO MN-48 E, 23.4 MI. CONTINUE ONTO W-77 E. 4.0 MI. TURN LEFT ONTO WI-35 N/WI-77 E. 2.2 MI. TURN RIGHT ONTO W-77 E, 26.8 MI. TURN RIGHT ONTO US53 S, 0.2 MI. SLIGHT LEFT TOWARD US-53 N, THEN MERGE ONTO US-53 N, 0.2 MI, TURN RIGHT ONTO W-77 ENV HOKAH ST, 24.4 MI. TURN RIGHT ONTO W PENINSULA RD, 1.4 MI. TURN RIGHT ONTO CO HWY K, 1.0 MI. TURN LEFT ONTO CO HWY B/CO RD B. 5.2 MI. TURN LEFT ONTO N MCCLAINE RD, 0.3 MI. TURN RIGHT ONTO W LAWRY RD, 0.5 MI. TURN LEFT ONTO ACCESS ROAD. SHEET NO: G-001 G-002 C-101 C-201 C-401 C-501 E-501 SHEETINDEX DESCRIPTION TITLE SHEET GENERAL NOTES DETAILED SITE PLAN TOWER ELEVATION ANTENNA INFORMATION & SCHEDULE CONSTRUCTION DETAILS GROUNDING DETAILS SUPPLEMENTAL SHEETS (3 PAGES) REV: DATE: 05119/25 BY: JM 0 0 05/19125 JM 0 05119/25 JM 0 05/19/25 JM 0 05/19/25 JM 0 05/19/25 JM 0 05/19/25 JM A, _ 111N11eRICAN TOVI/ER• ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069.11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE OQ FOR CONSTRUCTION JM 05/19/25 IL 0 0 ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: AlN0963A SITE ADDRESS: 11556W LAWRY ROAD HAYWARD,WI 54843 SEAL: IAf �r SANTHOSHArl�� SHANBHOGUE -o E-49097 S �o CARY N 1 ��lr,`f,II1� � Q N A � L. �����`�``• lanthos iiMX signed by Santhosha ihanbhog Shanbhogue Date: 2025.05.20 t e 08:21:06-04'00' T - -Mobile PROJ. #: 15315647 GO LCA'T,C UST.ID: AIN0963A ST.#: AlNO963A TITLE SHEET SHEET NUMBER: REVISION: G-001 0 GENERAL CONSTRUCTION NOTES: 1 OWNER FURNISHED MATERIALS, T-MOBILE -THE COMPANY' WILL PROVIDE AND THE CONTRACTOR WILL INSTALL A BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUND BUILD/CO-LOCATE ONLY) B AC/TELCO INTERFACE BOX (PPC) C ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILDICO-LOCATE ONLY, GC TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION) D. TOWERS, MONOPOLES E. TOWER LIGHTING F GENERATORS d LIQUID PROPANE TANK G ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING H. ANTENNAS (INSTALLED BY OTHERS) I TRANSMISSION LINE J. TRANSMISSION LINE JUMPERS K. TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITS L. TRANSMISSION LINE GROUND KITS M. HANGERS N. HOISTING GRIPS O BTS EQUIPMENT 2 22. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIRED PERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THE CONTRACTOR. 23 CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILE SPECIFICATIONS AND REQUIREMENTS. 24. CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 25. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND AS SHOWN IN THESE PLANS. 26. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 27. CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR SEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW AND THE CONTRACTOR IS RESPONSIBLE - PROVIDE ALL OTHER MATERIALS FOR THE APPROVAL. COMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCH MATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB -FRAME FOR PLATFORM, 28 ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES, COPPER -CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER, CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS AND RUBBER MATTING, REPAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS, MISCELLANEOUS FASTENERS CABLE TRAYS NONSTANDARD ANTENNA FRAMES AND WHEN THE PROJECT SCOPE REQUIRES THE USE OF THE SAFETY CLIMB, THE GENERAL CONTRACTOR SHALL ENSURE THE SAFETY CLIMB IS FREE OF OBSTRUCTIONS, NOT RUBBING ON OR TRAPPED BY ANY INSTALLED CUSTOMER EQUIPMENT, IS VISUALLY TAUT, MEETS MANUFACTURER INSTALLATION SPECIFICATIONS, AND IS FIRMLY SECURED AT ALL CABLE GUIDE LOCATIONS UPON PROJECT COMPLETION ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO 20. COMPLETION OF PROJECT SHALL NOT OBSTRUCT, TRAP, LOOSEN, OR OTHERWISE THE DRAWINGS AND SPECIFICATIONS IT IS THE POSITION OF T-MOBILE TO APPLY FOR CAUSE FAILURE TO MEET MANUFACTURER INSTALLATION REQUIREMENTS FOR THE PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED SAFETY CLIMB. PERMITS. 30. CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITH 3 ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCAL ALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALL CODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTION NECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICES SPECIFICATIONS. SUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING, TRENCH BOXES/SLOPING, BARRIERS, ETC. 4 CONTRACTOR SHALL CONTACT LOCAL el FOR IDENTIFICATION OF UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. 31 THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANY 5 CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED DAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THIS INSPECTIONS. CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HIS WORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS 6 ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND EXPENSE TO THE OWNER'S SATISFACTION SITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALL DISCREPANCIES REPORTED TO THE ENGINEER. 32 ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED THE QUALITY OF WORKMANSHIP 7 DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. SHALL BE SUBJECT TO THE APPROVAL OF THE TSIOBILE REP ANY WORK FOUND BY THE T-MOBILE REP TO BE OF INFERIOR QUALITY ANDIOR WORKMANSHIP SHALL BE REPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS B DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS OBTAINED. OTHERWISE NOTED 33 IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF 9 THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION MATERIALS LISTED HEREINAFTER BY MANUFACTURER'S NAMES AND/OR SAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. MANUFACTURER'S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERS AS SPECIFIED. 10 CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING, 34 T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED -UP AT THE T-MOBILE WAREHOUSE, ANCHOR BOLTS, ETC NO LATER THAN 4BHR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTED AND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACE 11. CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS THE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BE DRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK. RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP. 12 INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR 35 T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANY NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILE EQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALL THE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THE REQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING. EQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO T-MOBILE OR THEIR ARCHITECTIENGINEER 13 EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS SPECIAL CONSTRUCTION 14. CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS ANTENNA INSTALLATION NOTES: PROJECT TO MATCH EXISTING PRE -CONSTRUCTION CONDITIONS TO THE SATISFACTION OF THE T-MOBILE CONSTRUCTION MANAGER 1. WORK INCLUDED: 15 ALL CABLEICONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURING INSTALLATION USING A SILICONE SEALANT. A. ANTENNA AND COAXIAUHYBRID CABLES ARE FURNISHED BY T-MOBILE UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA 16 WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET INSTALLATION CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS. CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORD ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF IMMEDIATELY. PERSONNEL 17, CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE AND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. 18 CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF EACH DAY 19. CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWER CORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY 20. CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC) WITH A PDF MARKED UP AS -BUILT SET OF DRAWINGS UPON COMPLETION OF WORK B. INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND T-MOBILE SPECIFICATIONS. C. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS D. INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE, E INSTALL COAXIAUHYBRID CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL CONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. TERMINATE ALL COAXIAUHYBRID CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED 21 PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP 2. ANTENNA AND COAXIAUHYBRID CABLE GROUNDING: TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDED SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR CONTRACTOR WILL INSTALL ALL ITEMS PROVIDED. A ALL EXTERIOR 06 GREEN GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BE WEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT 9221213 OR EQUAL, B. ALL COAXIALHYBRID CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIAUHYBRID CABLE (NOT WITHIN BENDS) ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESE CONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATC ENGINEERING IMMEDIATELY FOR CORRECTION OR RE -DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING OR ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. lk AMIERICAN TOWER' ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27611 PHONE: (919) 466-0112 4089-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE OQ FORCONST'RUCTION. JM 05/19/25 Z\ A SEAL: ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: AIN0963A SITE ADDRESS: 11556W LAWRY ROAD HAYWARD,WI 54843 ���111{1111i111►���, ti•�' \5 C O Ns '�•. SANTHOSHA SHANBHOGUE -,o E-49097 � CARY w �0 NAL 11111111f1 Digitally Signed: 2025-05-20 T - -Mobile-- ATC PROJ. #: 15315647 GO CUST.ID: AlN0963A CUST. #: A1N0963A GENERAL NOTES SHEET NUMBER: REVISION: G-002 0 SITE PLAN NOTES: THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2. ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS. 3. NO ELECTRICAL SCOPE IS INCLUDED IN THIS PROJECT. PROPOSED (1) CERAGON IP20A IDU X - Hhfrl T-MOBILE (7'-10" X 8'-3" ` I PLATFORM W/ 12' X 16' 1 GROUND SPACE LEGEND x ® GROUNDING TEST WELL ATS AUTOMATIC TRANSFER SWITCH B BOLLARD CSC CELL SITE CABINET D DISCONNECT E ELECTRICAL F FIBER GEN GENERATOR G GENERATOR RECEPTACLE HH, V HAND HOLE, VAULT IB ICE BRIDGE K KENTROX BOX LC LIGHTING CONTROL M METER PB PULL BOX PP POWER POLE T TELCO TRN TRANSFORMER CHAINLINK FENCE PROPOSED CABLE NOTES: 1. ESTIMATED LENGTH OF PROPOSED CABLE IS 336'. ESTIMATED LENGTH OF CABLE WAS PROVIDED BY CUSTOMER OR CALCULATED BY ADDING THE RAD CENTER AND THE DISTANCE FROM THE SHELTER ENTRY PLATE TO THE TOWER (ALONG THE ICE BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF 15% (OF THE TWO PREVIOUS VALUES), COS DEFER TO GREATEST CABLE LENGTH. 2. ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE EXISTING CABLE SUPPORT STRUCTURES AS PROVIDED FOR CARRIER TO ADEQUATELY SECURE CABLES, USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP -INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. OTHERWISE, ATTACH CABLES TO HORIZONTAL OR DIAGONAL TOWER MEMBERS USING PROPOSED STAINLESS STEEL ADAPTERS (DO NOT ATTACH TO TOWER LEG). EXISTING (2)1.8- FIBER (TO BE REMOVED) PROPOSED (2) 2.00" HYBRID, (1) 0.63" CONTROL CABLE, AND (1) 0.39' FIBER TRUNK (SEE PROPOSED CABLE LENGTH NOTES ON THIS PAGE FOR LENGTH AND ROUTING GUIDELINES) GUYED X TOWER PLATFORM -Il X T= 1 M — x 1 DETAILED SITE PLAN GRAPHIC SCALE 10 0 5 10 (IN FEET) 1 UNIT= 10 FEET AP11CIRICAN T4D VWIEW ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 4684112 4089-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE QO FOR CONSTRUCTION JM 05119/2 0 0 0 ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: AlNO963A SITE ADDRESS: 11556W LAWRY ROAD HAYWARDA 54843 SEAL: wllflllllll111►I SANTHOSHA SHANBHOGUE E-49097 CARY ,(uj 0,� NC N A \- '�►11111111111"o Digitally Signed: 2025-05-20 T • mMobile- ATC PROJ. #: 1531564LGO CUST.ID: AIN0963A COST.#: A1N0963A DETAILED SITE PLAN SHEET NUMBER: REVISION: C-101 0 TOP OF EXISTING OL MIGHFST APPURTENANCE ELEV 302.76 OL TOP OF EX15nN6 TOWER Ilqw ELEV 3W' EXISTING AND 1 2 PROPOSED T-MOBILE 40t .40 EQUIPMENT AND MOUNT MODIFICATIONS (TO BE F PROPOSED (2) 2.00" HYBR CONTROL CABLE, AND (1) 0.39" FII (SEE CABLE NOTE, TOWER ELEVATION SCALE: N.T.S. EXISTING CARRIER ANTENNAS` RAD CENTER ® ELEV 295. 1'� EXISTING T-MOBILE RAD CENTER 0 2B4' EXISTING CARRIER ANTENNAS RAD CENTER ® ELEV 270' EXISTING CARRIER ANTENNAS RAD CENTER ® ELEV 253. 1 EXISTING CARRIER ANTENNAS jh, RAD CENTER ® ELEV 180" EXISTING TOWER EXIS77NG GRADE rl• ELEV 0'� PER MOUNT ANALYSIS COMPLETED BY ENGINEERED TOWER SPLUTIONS, DATED 04/25/25, THE EXISTING MOUNT MUST BE MODIFIED TO ADEQUATELY SUPPORT THE PROPOSED LOADING. THE MOUNT MODIFICATION PROPOSED IN THE MOUNT ANALYSIS, INCLUDED AT THE END OF THIS PLAN SET, MUST BE INSTALLED PRIOR TO THE INSTALLATION OF THE PROPOSED ANTENNAS AND OTHER EQUIPMENT. TOWER NOTE: 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONFIRM WITH THE PROJECT MANAGER THAT THEY HAVE THE MOST RECENT VERSION OF THE STRUCTURAL ANALYSIS BEFORE COMMENCING WORK. EXISTING AND PROPOSED TOWER APPURTENANCES, MOUNTS, AND ANTENNAS ARE SHOWN BASED ON THE STRUCTURAL ANALYSIS. 2. WHERE APPLICABLE, ALL NEW ANTENNAS, EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BE PAINTED/SOCKED TO MATCH EXISTING EQUIPMENT IN ACCORDANCE WITH FAA, JURISDICTION, AND/OR OTHER LOCAL REQUIREMENTS. 3. ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE EXISTING CABLE SUPPORT STRUCTURES AS PROVIDED FOR CARRIER TO ADEQUATELY SECURE CABLES, USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP -INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. OTHERWISE, ATTACH CABLES TO HORIZONTAL OR DIAGONAL TOWER MEMBERS USING PROPOSED STAINLESS STEEL ADAPTERS (DO NOT ATTACH TO TOWER LEG). 4. TOWER ELEVATION DEPICTION MAY NOT REFLECT ALL EQUIPMENT INCLUDED IN STRUCTURAL ANALYSIS. REFER TO STRUCTURAL ANALYSIS FOR FULL TOWER LOADING. AMERICA111 TCNWER• ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4089-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE A._ FOR CONSTRUCTION. JM 05/19/2 A -. 0 - 0 ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: Al N0963A SITE ADDRESS: 11556W LAWRY ROAD HAYWARD,WI 54843 SEAL: �►►►►+11 1111111 r1j1j SANTHOSHA SHANBHOGUE -o E-49097 CARYLQ NC 1j1f111,111FI►F111.111 Digitally Signed: 2025-05-20 T m, mI-obile* ATC PROJ. #: 115315647 GO CUST.ID: AlN0963A 1 CUST. #: I Al N0963A I TOWER ELEVATION SHEET NUMBER: I REVISION: C-201 I 0 EXISTING AEHC ANTENNA TO REMAIN (1 PER SECTOR) (TYP. 2) A2 EXISTING TOWER 1' EXISTING SECTOR MOUNT (TYP.) C 1 i+ i PZ G��P ti,+i C2 •�� EXISTING AEHC ANTENNA (TO BE RELOCATED) (TYP. 1) EXISTING FFW-65C-R3-Vl ANTENNA TO REMAIN (1 PER SECTOR) (TYP. 3) - EXISTING AHFII RRU TO REMAIN Al ✓ (1 PER SECTOR) (TYP. 3) i r�y I �a EXISTING AHLOA RRU TO REMAIN 0 PER SECTOR) (TYP. 3) Y. _ - B2 '_�o- B1 (D EXISTING ANTENNA PLAN N SCALE: N.T.S EXISTING ANTENNA SCHEDULE LOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY SECTOR RAD AZ POS ANTENNA BAND MECH/ELEC STATUS ADDITIONAL TOWER STATUS D-TILT MOUNTED EQUIPMENT Al FFW-65C-R3-VI L700IL600IN600IL2100 0%2' RMN AHLOA RUN ALPHA 284' 0' L1900IN1900 AHFII RMN A2 AEHC N2500 0%2' RMN - - B1 FFW-65C-R3-V1 L700IL600IN600IL2100 0%2' RMN AHLOA RMN BETA 284' 120' L1900IN1900 AHFII RMN 82 AEHC N2500 0%2' RMN kC2 i FFW-65C-R3-V1L700IL600/N600IL2100 0%2' RMN AHLOA RMN GAMMA 284' 240' L1900IN1900 AHFII RMN AEHC N2500 0%2' REL - EXISTING AEHC ANTENNA TO REMAIN (1 PER SECTOR) (TYP. 2) A2 EXISTING TOWER - j EXISTING SECTOR MOUNT (TYP.) I I CI EXISTING AEHC ANTENNA (RELOCATED) (TYPA ) PROPOSED VHLP2-11 W/A - MICROWAVE DISH 91 -5D1 (MOUNT PER MANUFACTURER'S SPECS) NOTES 1. GC TO VERIFY THE FINAL RFDS LOCATION MATCHES THE FINAL CONSTRUCTION DRAWINGS. SECTOR RAD GC TO NOTIFY ATC PM OF ANY DISCREPANCY PRIOR TO INSTALLING THE EQUIPMENT. 2. GC TO CAP ALL UNUSED ALPHA 284' PORTS. 3. GC TO CONFIRM SPACING OF PROPOSED EQUIP DOES NOT CAUSE TOWER CONFLICTS NOR IMPEDE TOWER CLIMBING PER MOUNT ANALYSIS COMPLETED BY ENGINEERED TOWER SPLUTIONS, DATED 04/25/25, THE EXISTING MOUNT MUST BE MODIFIED TO ADEQUATELY SUPPORT THE PROPOSED LOADING. THE MOUNT MODIFICATION PROPOSED IN THE MOUNT ANALYSIS, INCLUDED AT THE END OF THIS PLAN SET, MUST BE INSTALLED PRIOR TO THE INSTALLATION OF THE PROPOSED ANTENNAS AND OTHER EQUIPMENT. AI — EXISTING FFW-65C-R3-Vl - ANTENNA TO REMAIN (I PER SECTOR) (TYP. 3) I + EXISTING AHFII RRU TO REMAIN (1 PER SECTOR) (TYP. 3) - EXISTING AHLOA RRU TO REMAIN (1 PER SECTOR) (TYP. 3) B2 ti ti'4 •�� B1 PROPOSED MOUNT MODIFICATIONS (REFER TO SHEETS AT THE END OF THIS PLAN SET) (1) PROPOSED FIBEAIR IP-20D-HP G 2 FINAL ANTENNA PLAN SCALE: N.T.S. FINAL ANTENNA SCHEDULE ANTENNA SUMMARY AZ POS ANTENNA BAND L700IL600IN6001 0' PEGS. BETA 2W 120" STATUS ABBREVIATIONS RMV: TO BE REMOVED RMN: TO REMAIN 240° REL: TO BE RELOCATED GAMMA 284' ADD: TO BE ADDED CABLE LENGTHS FOR JUMPERS JUNCTION BOX TO RRU: 15' RRU TO ANTENNA: 10' EXISTING FIBER DISTRIBUTION I OVP BOX EXISTING CABLING SUMMARY MODEL NUMBER STATUS CABLE OTY, SIZE, TYPE STATUS RMN ---- RMN EQUIPMENT SCHEDULES RMV (2) 1.8" FIBER RMV 3 Al FFW-65C-R3-VI L2100 L1900IN1900 A2 AEHC N2500 L700IL600IN6001 B1 FFW-65C-R3-VI L2100 L1900IN1900 B2 AEHC N2500 L700IL600IN6001 C1 FFW-65C-R3-VI L2100 203.66'1 DISH L1900IN1900 AEHC N2500 VHLP2-11 WIA NON ANTENNA SUMMARY MECHI ADDITIONAL TOWER ELEC STATUS MOUNTED EQUIPMENT STATUS D-TILT 0-12' RMN AHLOA RMN AHFII RMN 0%2- RMN - - 0%2' RMN AHLOA RMN AHFII RMN 0%2- RMN - - 0%2' RMN AHLOA RMN AHFII RMN 0%2- REL i - ADD FIBEAIR IP-20D-HPAD I ADD FINAL FIBER DISTRIBUTION / OVP BOX FINAL CABLING SUMMARY MODEL NUMBER STATUS CABLE OTY, SIZE, TYPE STATUS RMN ---- RMN (2) 2.00' HYBRID, (1) 0.63' CONTROL ADD CABLE, AND (1) 0.39' FIBER TRUNK ADD AMERICAN TOWER' ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4089-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE 00 FORClONSTRUCTION JM 05/19/25 A. 0 - - — ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: Al N0963A SITE ADDRESS: 11556W LAWRY ROAD HAYWARD,WI 54843 SEAL: r A' SANTHOSHA SHANBHOGUE E-49097 o CARY .-^ NC 40 �0INIAI`0\� Digitally Signed: 2025-05-20 T - -Mobile ATC PROJ. #: 15315647 GO CUST.ID: AlNO963A CUST.#: AIN0963A ANTENNA INFORMATION & SCHEDULE SHEET NUMBER: REVISION: C-401 0 EXISTING/PROPOSED MOUNTS AND/OR MOUNT MODIFICATIONS NOT SHOWN FOR CLARITY. REFER TO ANTENNA PLANS, MOUNT ANALYSES AND/OR MOUNT MODIFICATION DOCUMENTS FOR ADDITIONAL DETAIL. PROPOSED ODU EXISTING OR PROPOSED MOUNTING PIPE IROPOSED DISH BRACKET 'ER MANUFACTURER PROPOSED MICROWAVE DISH (MOUNT PER MANUFACTURER'S SPECIFICATION) ,I PROPOSED DISH AND ODU MOUNTING DETAIL - TYPICAL SCALE: N.T.S. 'r AMERICAN TOVWR• ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 466-0112 4069.11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE A0 FOR CONSTRUCTION JM 05/19125 A An / \ ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: Al N0963A SITE ADDRESS: 11556W LAWRY ROAD HAYWARD,WI 54843 SEAL: 1� to 1����'''�-, .~``t`'•'�,� =�* SANTHOSHA : SHANBHOGUE E-49097 CARY :�.o NC =� '�f'f.,,��., N A 1.� ���.•��'�,, rp ++r r I I u+ Digitally Signed: 2025-05-20 m - •Mobile ATC PROJ. #: 15315647 GO CUST.ID: AIN0963A CUST.#: AIN0963A CONSTRUCTION DETAILS SHEET NUMBER: REVISION: C-501 0 PROPOSED ANTENNA EXISTING ANTENNAS TO EXISTING ANTENNA MASTS EXISTING COAX GROUND KITS PROPOSED #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION TO PROPOSED RRU GROUND LUG (TYP.) GROUNDING CONNECTION TO EXISTING TMAs PROPOSEDJUMPER PROPOSED CONNECTOR AND WEATHERPROOFING KIT PROPOSED WEATHERPROOFING KIT — PROPOSED CABLE 2 GROUND KIT 501 r I ANTENNA CABLE TO I CABINET (TYP.) r� #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION EXISTING GROUNDING — GROUND BAR MOUNTED CONNECTION TO NEAR/BELOW ANTENNA (1 3 Jl LIGHTNING (TO BE INSTALLED IF PROTECTION SYSTEM REQUIRED) NOTES: 1. THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHT ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THE CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THE CONSTRUCTION MANAGER OF ANY CONFLICTS. 2. SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATEST EDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN. 0 TYPICAL ANTENNA GROUNDING DIAGRAM SCALE: N.T.S. STANDARD CONDUIT USE TABLE TO ANTENNA ANTENNA CABLE 2 1/2'0 MAX GROUNDING KIT PER CABLE MANUFACTURER'S RECOMMENDATIONS (ANDREW OR APPROVED EQUAL) #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) TO GROUND BAR TO EQUIPMENT GROUND KIT NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PART NUMBER 221213) AND INSTALUTAPE PER MANUFACTURER'S SPECIFICATIONS CABLE GROUND KIT CONNECTION DETAIL SCALE: N.T.S. CONDUIT USE CASE LOCATION USE CASE EXAMPLE TYPE RMC ABOVE GROUND (METALLIC) AC, DC COMM ABOVE GROUND PPC TO SSC UNDERGROUND PPC TO SSC OR BACKHAUL PVC AC POWER UNDERGROUND TRANSPORT HUB TO SSC MAX 6' PER CONDUIT RUN, TIGHT LOCATIONS BETWEEN HUB AND CONDUIT BUT NOT LFMC AC, DC, COMM ABOVE GROUND ONLY INDOOR NOT EXPOSED TO THE OUTDOOR TO BE USED WHERE IT CAN BE STEPPED ON EMT INDOOR AC, DC CIRCUIT PANEL TO JUNCTION BOX COMM ENVIRONMENT (MUST BE DRY) LFNC CONCEALING AND PROTECTING BTCW RISERS GROUND RING TO MGB OR SSC GROUND WIRE ONLY EXCEPTION CONDUIT USE TABLE CONDUIT I USE CASE ` LOCATION USE CASE EXAMPLE TYPE EMT OUTDOOR DC, (NOT PREFERRED) COMM RMC OUTDOOR/INDOOR NONMETALLIC PER NEC (ALUMINUM) GUIDLINES OUTDOOR WHEN USED WITH WATERTIGHT HUBS ONLY ABOVE GROUND BETWEEN EQUIPMENT AND BATTERY CABINET OR EQUIPMENT TO EQUIPMENT CABINETS FOR INTER CABINET CONNECTION MAT BE USED AS A LOWER COST ALTERNATIVE TO METALLIC RMC, MUST MEET OR EXCEED FEDERAL SPEC: WW-C-540C, ULSA, ANSI C80.5, NEC 344.10 (A) ALLOWS THE USE OF EITHER ALUMINUM OR GALVANIZED FITTINGS CONDUIT USE TABLES PROPOSED CABINET #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR EXISTING EQUIPMENT GROUND BAR (TYP.) — 3/8" X 1-1/2" SS BOLT (EACH SIDE) 3/8" SS LOCK WASHER (EACH SIDE) r � f� yr r / / s ',�Y OAppOA .�/ 0 1/4" X 4" X 6" GROUND BAR (ERICO PIN: EGBA14406CC OR EQUAL) TWO -HOLE LUG, TO BE USED WITH #2 AWG BCW (LOWER TOWER GROUND BAR ONLY) CABINET GROUNDING DETAIL SCALE: N.T.S. GROUND BAR NOTES: 1. GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS, WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). 2. GROUND BAR TO BE BONDED DIRECTLY TO TOWER. S TOWER GROUND BAR DETAIL SCALE: N.T.S. ELECTRICAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. 2. ATC HAS NOT VERIFIED ANY EXISTING T-MOBILE GROUND EQUIPMENT OR ELECTRICAL LOADING. PROPOSED WORK BASED ON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE. CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HAS SUFFICIENT SPACE FOR PROPOSED BREAKER, PROPOSED CABLE AND CONDUIT SHALL BE MINIMUM SIZE PER BELOW IN CHART. 3. FOR SPECIFIC CABINET/ANCILLARY EQUIPMENT WIRING REQUIREMENTS, THE T-MOBILE CONTRACTOR SHOULD REFERENCE DESIGN DOCUMENTS PROVIDED BY T-MOBILE FOR THIS CURRENT PROJECT CONFIGURATION, IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS & NEC STANDARDS B PRACTICES. VOLTS OCPD SIZE WIRE SIZE GROUND CONDUIT 1201240V OR 120 ABV 80AI2P 343AWG #8 AWG 1-1/4" 1.1 /4" 2" 100/2P 342 AWG 08 AWG 125A/2P 3413/0 AWG #6 AWG 150A/2P 34/3/0 AWG #6 AWG 2" 200A/2P 343/0 AWG #6 AWG 2" 240V OR 208V BOA/2P 243 AWG #8 AWG 1-1/4" 10012P 242 AWG #8 AWG 1-1/4" 125AMP 2-#3/0 AWG #6 AWG 2" 150A/2P 2400AWG #6 AWG 2" 200A2P 2-MO AWG #8 AWG 2" fi ELECTRICAL NOTES AMERICAN TOWER• ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 466-0112 4069.11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV DESCRIPTION BY DATE OQ I -OR= ONSiRUCNON JM 05119/25 0 ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: Al N0963A SITE ADDRESS: 11556W LAWRY ROAD HAYWARD,WI 54543 SEAL: ,,}}}}}1111111111j17j C 0 SANTHOSHA SHANBHOGUE E-49097 CARY ;"J i .4% NC NIAI`���, Digitally Signed: 2025-05-20 T - -Mobile ATC PROJ. #: 15315647_GO CUST.ID: A1N0963A CUST. #: Al N0963A GROUNDING DETAILS SHEET NUMBER: REVISION: E-501 0 Dab Printed: [DATE] Link ID: 5019747 Region: Central Create Dab: 01-MAR-2025 Llnk Nama:A1N0903A_A1N0249A Craatsd By: AHentgat D14arm(ml)w Helght(R) Path length (9 50 ml) A1N0997A ! F404P IO (OHa) - 11.00 GNe AIN0249A L,vv,'A 15 50 K6 N K1;'"Ij I I LWlludv:)15.52.2D9H LmOttude: )1-18-135 W %F1�PL-F1] Lonp1lude91-20-561 W Azimuth 203 66 Deg K2:IPL-K2] Azlmulh :!3 60 Deg Elevation: 141732 R %F2:lPL-F2] Elevation 1159121it Antenna CL 284 00 R AGL K3: IPL-K3] Antenna CL :115 00 RAGL IPL-+31 J - 3 nm.mkwraswNc _ ---- ---r A, 11D963A A1N0249A [CLUSTERJD_LABEL): [CLUSTER -ID A] ]CLUSTER ID B) [CAL-SIGN_LABELM [CALL_SIGNA] [CALL_SIGN_B] _ AVkRIk AW CCWTRIICT_U DWESM TAAV CONTRAC?_ID_S] AAPF 0&0TRACTjPATYk Belamed NotAvIlf" oumet4mulmd; _ _ [1 i5 STATUS -A [1 95 STATUS B] i.1811118s: 4.f"iB.&1.E N 45-52-20.9 N Lopommig; 91.1b13.6Y7 203.68 Deg 91-20-SB.1 W 23.60 Deg Aalmuth (dog):1 018 Up Vertical angle (dos): 0 20 Down Elevation:1 1417-326 159121 R Antenna mo4lN: VHLP2-11WA VHLP2-11WA Antenna manulaeturar.' ANDREW CORPORATION ANDREW CORPORATION Ardennald:l 207 207 Anlanna p91n ld0q; 51;70 dB1 34,i0 dBk arlanna dlonhvlar. �S4'I1l 5:9in Anion"CU 2uMI'libi. S1tiDp RA4 ............... . --- -- DNerellyAntanno model:) -----...__._•..- - DWerally Anle6ka ptantdodurer' Dimm"Ard-nZ id! Dlv-dy AM-6 galn Id Rly Diversity Antenna diameter: - - Dlv mltyAntonm CL: 1.00 dB/1 00 dB Branchl.oss T1104x IdM; IADdSM-N dB All4nual04 CdagnpNtltPo! [d8]: Wommquida s1 Mpdal, Lm%LosaM; Waysgulde 02 Model, Lon, Lose(dB): 1Navoglida%S iAod�I, LuLLosa(dBJ: - - Total Vhveod■ Loss WSJ! - - tri Loasas (dB): 000 d13 000 dB Froquancy[GHar. Gift Pali Ydpm: mi Fm space lash (dEM _ _95 _ 18699 d6 =do - AlmaaphwleehsarPdnnIon I k OEatrunlon Lwa WK . Fuld nurgfn Idek - A0FWR(oLOS) tAD dB Helpalh lass (als): 7D7g'm 70.79 de ConngurnUme 2e01DIPMA1NOAR 2•aOPR]lvpl,[I - Radio modal:. IPII-8nx-A-4501 Redo manutacturar:l Ceregon Networks Ceragon Networks Red W Id; T54 754 pp0ueadY Plan: Frpduency(N[iy:, High: WA Low: WA Polarlrallon: WA AYA 5mlualm dnlgnsbr: 8DWD7W 80M007W It 100 Ttrrialn rarphnss hclor: 0-T3 A47st8ga anMlel lmlprydnt; i9,42 depF Du1pn Pads PplarhK lAlr6COl Rain regla . I Dufuth.AYxglkpb . Fsuplae Repaalln Antenna modallj - _ Antenna me Lt"renj - - Anterprahelgm:j - Hodulatlon( Thmphput TUPas4ar A/8 URP Ale(dhm) ease ZWW'• Dan Pottia 0ai,1slMa+piW6T AH(dpm) Palo Harpllr Al9 AMaoplerel- Ida) 1Ue Ism) BPSK 67.00 Mops 36.00 36.00 69,70 69.70 33.79 T-3379 51.23 51.23 1 4%30 186.30 4QAM I I9.00 Mops 3600 36.D0 69.70 69.70 -33 79 -33.79 4SA4 45 64 -80 50 -80.50 _ SW 195,00 Mops 36,00 36.00 69.70 6970 -33 79 -33.79 41.98 4196 -76.60 -76.80 16%%M 244.00 Mops 35.00 35.00 66.70 6670 -34.79 -34.79 3800 3a00 .73.90 1 -73AD 32QAN 321ADMW 35,00 35A0 6870 68.70 -34.79 -34.79 34.54 j4-u -70.40 -78A0 AW 394.00 Mhos 34,00 34.00 0720 el. 7u 3Yn -35:N 3064 MM -67.50 fi7.50 121W 46GOO Mps 13 m 3 z nn ea m 66.70 -36.79 -36.79 2666 25.66 -64.50 -64.50 736QAM i17A0 Mops 32,01 31.10 1170 0,18 -37.79 -37.79 2296 22.98 [ 451A0 fi1.BD S12QM1590.00 Mbpa 3200 3200 65.70 65.70 -37. N A4 A;29 k 4alw 1•3a. 10 IIO-QAM 612.00 Mbps 3lm 11.Vu u.70 j 64.70 30.79 28.79 14Mj-'56.90 -9.90 _ 1KHQAM 682.00 Mbps 31.00 31 00 iwo 64.70 -38.79 �38,79 15.j{ -55.50 2KOAM 772.00 Mbps 3100 31.00 H.70 H.70 ak79 _AS.SO 9B.ih ]zj •51A0. -SIA9 w,.r nr, ire.r nal�miwdw wy �1 rw wtl I --memo -emmow tU nva r) � is 0.1 40-11 1•1 frow T Iq 0as+s) (y is�� laaro4l'4 as 'n.»e {j 4ue -1411 nWvr-aee s.n ne+.wh .�r mrr xa Damns nn p1•t64ara raaHtat 4EI M.xxHril 9allllr me N35 seem .! spn ntrue� eaa.net' 4A .��I 11.14 r♦-a�li i4i MRm, r, C. p..;; n.n OnOIK avaa 144WI1MN 1a111414 ]I fv.>•+x1W1F I414 naana r».� m.r. h-M.. aaaaat �ReO a1.HSIHyj] 1rM nwwri asFsr- 4a lull f.1�3r�ln.v 0.00HM ]NY ..��LWI�i sqw se%si_ar w.rorwl n-�i ...e.eii i i+nn xti�ile` 'a7ia oei>a an.. 11raR rasa IRlgtl Isan wn..+ aawpr 4na1n�'+s MIA iN�a'kM asgsss ss-�Jau� essws w .y.,.,1x unn n.nun- ms 7r-twrx r74s xr �amesxl ussH B>44nmmt� aura taaxt roaartas to1a4 hawzots hew wssna mas Tn.roa xro+sh ; oa+nz j •m.n IRpW Hte0l�llf 4{tlegf ands :, ss rh c• u_u as.ro4w smb xarn nar,ls wanur • I uigrn m.nri. •ratmah. wen e,.w;c,i [df .s w,txu anxa srzshst stam9al 74n31 asxxxn� ussaa lKpyhlROl rCw naupr aMlal ronlusl s4An nssW fauAs tnauar xrxfl tlHsos wxa74 1arrAs narm M18Pa8h fadkq rr W d - Vl0AN15 Pat+ Wing medmd - Aum Cram Coy/DutAh, Manewta 91 NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT SUPPLEMENTAL SHEET NUMBER: REVISION: R-601 0 Product Specifications COMM5COPEe VHLP2-1 1 W/A 0.6 Fin 1 2 ft Valut-Wea4 High Performance I"Pro[II! Antenna, single-potarized, 10-0- 11.700 ONz GarNral Sp•Cificallons Antenna type VHLP - ValuLJnex- High Performance Low Profile Antenna, single -polarized Diameter, nominal 0-6 m 12 R Polarization Single Electrical Spec ficatians Beam width, Horizontal 3.31 Beamwldth, Vertical 3.3 e Cross Polarization Discrimination (KPU) 30 dB Electrical Compliance Brazil Armatel Class 2 1 E1S1 302 217 Class 3 1 US FCC Part IOTA @� 10.55-10.7 GHz I US FCC Part 1011D @, 10.7-11.7 GHz Front -to -Back Ratio 61 dB Gain, Low Band 33.7 dBi Gain, Mid Band 34.S d8i Gain, Top Band 35.2 dBl Operating Frequency Band 10.0 - 11.700 GHz Radiation Pattern Envelope Reference (RPE) 7200A I 7201A Return Loss 17-7 dB VSWR 1.30 IMnichanical Specifications Fine Azimuth Adjustment Fine Elevation Adjustment Mounting Pspe Diameter Net Weight Side Struts, Included Side Struts, Optional Wind Velocity Operational Wind Velocity Survival Rating *150 *lso 50 cam-120 min 1 2.0 in-4-7 in 8 kg 1 17 lb 0 0 1801a1Hh I 112 mph 250 km/h I 155 mph Wind Forces At Wind Velocity Survival Rating Axial Force (FA) 1290 N 1 290 Ibf Side Force (FS) 639 N [ 144 lbf Twisting Moment (MT) 39S N•m Weight with 1/2 In (12 mm) Radial Ice 21 kg 1 46 lb Zcg with 112 In (12 mm) Radial toe 106 mm 1 4 in C E1 tAG"r,P High -availability, split -mount, modular multicore aggregation node nesgned uniquely far the Narrh American marlin. FbMrr IP•20A Is a highyr-nexmtile aggregarxsn nodP Thal detmvefs mukifibps radio rapadr ty al a very large Seale Now avadab* swdh mule car we tedxiniogy and new radio LiMs. iP-10A feaiurm hsgri modularity and fiexihility and supports up to A radio links with an except lonarly wide Y2hety of fine L lterfar¢s via pitggzbie modules, In a wide range of network topologies - making it the preferred rode for your transport network's aggregation sites. The FibaAlf a-20A operates within the entire microwave and nsilsmater-wawa spent rum, offering high spectral of ciency across licensed and Leersse rx^mp[ frcqucncY band: 14 B6GH0- It also supportm all high speed data interfaces [LOG/1G;FEI and a wide variety of TDM Interfaces IDS1, OC-3); Operates with a wide variety of an utticare, standard and high power radio; and accornmodates various network configurations including Ix 1140, 4x 2.(X and for 1+0. Note: rcremcee texture awRablNty, contactyour ceap ri represenutlre. In case of discrepancy beUaeen this Dataslieet arulthe Ier.hn-"I UPSCr.ptmdn UV the prndarr- the fechfuc4V a(&Arrir,, i r ,i-, I-. General )WIC Multiband jwith IP-SOE/ P-20E) Assembly options Advanced Space Diversity (ASD)' 1RU Chassis - Sx Universal slots; Field Replaceable Diplexers/ Field Replaceable Channel F Iters 2RU Chassis -IOx Universe slots Ethernet Redundant TCC slots 12RU chassis; only) Radio Ethernet Interfaces 1RU/2RU Traffic Interfaces - Up to 10 x 1000Base-T (R11S) or Supported Frequency Range 1000base-x(sFP) Standard Power: 6-42 GHz, 71-76 G14, $1,86GHs lip to 2 x IOGbase-K (SFP+) Iiglm Poorer: 4-Si GHz Management Interfaces - 2 x 10/100 Base-1 (RI.45) SFP Type- - Optical 10ODBase-Lit (1310 nm) or SK (950 rim) Supported RFUs Ethernet Features RFU-D - High -capacity MukiCore radio Mnl - 9600 Dytes RFU-D-HP - High -capacity, high -power MulliCore radio Clinality of Service RFU-E - High capacity E-band radio • Mulhp!Y Ctin illl:a[rdn L'rllerld (VthN rU P•brPs. IPyA RFLFS - High-capecky radio DSCP, IPv6 TC, MPLS ExPI RFU-C - High -capacity rad o 8 prior queue3 icy per port RFU-A - Hip-capadty, high -power radio Deep ii ••• • ring (configu able up to 64 Mbit per queue) 1500HP/RFU-HP - H*t aapaury, high -power radio WRED Typical Radio Configurations Pbitmarking/ramarldng N40 (up to N e81,1x 8+0, 2m 4a0, 4x 2►% 811+8,1 ♦1, 2+2 4K VLANs Spit Mawr (Standard Power, High Power) VLAN add/remove All Indoor With Power) MSTP, ERP (ITU-T G.8032) Radio Features Frame Cut Through - controslatency ed latey and PDV fo de ay sewsitiwe applicators Muki-Carrier Adaptive Bandwidth Control (up to 8•0) Header DeDuplicatlon - Capacity boosting by eliminating Protection and Diversity: HSB, SO I BBC and BBS) Inefficiency in all layers (L2N PLS, L3,14, Tunneling - GTP for High surctral utiliation: BPSK to 4096 GAM w/ACM LTE, GREI Channel bandwdth: y 1731 Ethernet OAM 4a2 GHz: up to 112 MHz y.1731 Ethernet Bandwidth Nolirrcation ETH-BNI E-ltand: up to 500 MHz Nuts: I12 cha nnq is era planned Ipr jut t+re release. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SUPPLEMENTAL SHEET NUMBER: REVISION: R-602 0 AL AMERICAN TOWER" C O R P O R A T I O N This report was prepared for American Tower Corporation by -A ENGINEERED TOWER SOLUTIONS Antenna Mount Analysis Report Eng. Number 15315647_C8 02 ENGINEERED April 25, 2025 —A TOWER SOLUTIONS Page 4 Conclusion Based on the analysis results, the antenna mount meets the requirements per the applicable codes listed above provided the modifications listed below are completed: 1. Replace existing position I (looking from front, left to the right) with Site Pro 1 #P2120, 2.0 SCH 40 x 10'-0", A53 Gr.B (ANT.55993), P2,0 SCH40 120" long mount pipe. Connect with existing hardware. Mount pipe to be located 3 inches from left end of mount face looking out from tower on all sectors. 2. Install (1) Site Pro 1 #P296, 2.0 SCH 40 x 8'-0", A53 Gr.B (ANT.55983, or approved equivalent) mount pipe to be located 42" from right mount arm looking out from tower. Connect with with 00.5" U-Bolts, use existing bolt holes. Center mount pipes position 2 vertically 12 inches above mount centerline. The rough cost estimate is estimated to be 5$10k. No structural failures were addressed with the noted Mount Type 7.0 ft Sector Frame contingencies. Contingencies address Carrier's antenna spacing requirements. ATC Asset Name Round Lake WI If you have any questions or require additional information, please contact American Tower via email at ATC Asset Number 211543 MountAnalysis@americantower.com. Please include the American Tower site name, site number, and Engineering Number 15315647_C8_02 engineering number in the subject line for any questions, Mount Layout ETS, PLLC Job Number 25135226.STR.0923 Mount Elevation 281.25 ft Carrier T-Mobile Carrier Site Name AlN0963A Carrier Site Number AIN0963A Site Location 11556W Lawry Road Plan View Hayward, WI 54843 45.99849083,-91.27041375 County Sawyer �`§, �,�al+inr, r' rJ ❑ Date April 25, 2025 r. FREDERIC G. SOOT >"r Max Usage 90% ss Result Contingent Pass Prepared By: Reviewed By: 04/25/25 Jose Rahal Frederic G. Bost, PE Structural Engineer I CFO Engineered Tower Solutions, PLLC— 3227 Wellington Ct, Raleigh, NC 27615 - 919.782.2730 Office -www engineeredtowersolutions.com �1 MOUNT ANALYSIS I Engineered Tower Solutions, PLLC-3227 Wellington Ct, Raleigh, NC 27615 - 919.7822710 Office - www.engIneeredtowersoiutions.com NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. PLEASE REFERENCE THE MOUNT ANALYSIS REPORT FOR COMPLETE MOUNT ANALYSIS CALCULATIONS AND DETAILS. SUPPLEMENTAL PAGES INCLUDED IN THE CONSTRUCTION DRAWINGS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO VERIFY THEY HAVE THE MOST RECENT MOUNT ANALYSIS PRIOR TO CONTRUCTION. SUPPLEMENTAL SHEET NUMBER: REVISION: R-603 0