Loading...
HomeMy WebLinkAbout018-837-21-1203-LUP-2025-128m RIDGE VENTILATION SYSTEM ARCHITECTURAL ROOF SHINGLES ON SHINGLE UNOERLAYMENT ON 1/2" O.S.B. ROOF SHEATHING W/ H-CLIPS 6 EACH TRUSS SPACE ON ENGINEERED ROOF TRUSSES a 24" O.G. .ALUM. D-ROOF EDGE, FASCIA COVER, VENTED SOFFIT PANELS, 4 FRIEZE MOULDING 2X WOOD SUBF,ASCIA "PROPER -VENT" INSULATION BAFFLES a EACH TRUSS SPACE R-49 (MIN.) ,ATTIC INSULATION 5/8" GYPSUM BOARD (OR 1X6 WOOD PANELING) EXTERIOR SIDING ON TYVEK HOUSEWRAP ON 1/2" O.S.B. WALL SHEATHING ON 2X6 WOOD STUDS g 16" O.C. W/ R-21 (MIN.) WALL INSULATION 1/2" GYPSUM BOARD (OR 1X6 WOOD PANELING) ON POLY VAPOR BARRIER 2X6 SILL PLATE ON 2X6 TREATED MUDSILL PLATE ANCHORED TO FOUNDATION W/ 1/2" X S" GALV. ,ANCHOR BOLTS a 4'-0" O.C. 4 WITHIN w, OF ,ALL CORNERS PROVIDE SILL SEALER BETWEEN SILL PLATE 4 FDN. 4" REINF, CONC, SLAB ON 3" RIGID FOAM INSULATION ON POLY ro MIL POLY VAPOR BARRIER ON 4 (MIN.) COMPACTED GRANULAR FILL 3" RIGID FOAM INSULATION S" POURED REINF. GONG. FOUNDATION WALL 20" X 10" CONC. WALL FOOTING W/ 2 - *4 REBARS, CONT. ON UNDISTURBED SOIL OR COMPACTED GRANULAR FILL WALL SECT ION I 1 11 1/2" a �o I , I I , 1 1 , i 1 1 ; , � , 1 � , I 1 , ' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i ; - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 ------------------------------------------------------------------------------------------------------------------------------------------------------------------- LEFT SIDE ELEVATION 1/4" 1'-0" 1 I I ; I 1 I , 1 I 1 - - - - �-------------------------------------------------------------------------------------------------------------------------------------------------------------------- REAR ELEVATION 1/4" = 1'-0" I , 1 1 � 1 1 1 y 1 , RIGHT SIDE ELEVATION 1/4" = 1'-0" 1 I 1 I I 1 I I I I 1 -� ---------------------------------------------------------------------------------------;---------------------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FRONT ELEVATION 1,4" = 1'-0" UJ z � � O z Lu �o tu u z O z ul � Y tluu tu z U a O z � z QC (Nv � Q U ' DESIGN PHASE PRELIMINARY PLAN CHECK SET PLAN 4 APRIL 2025 FINAL CHECK SET PLAN 24 APRIL 2025 REVISION I REVISION 2 AkRMON EVERY EFFORT HAS BEEN MAIDE IN PREPARING THESE PLANS AND CHECKING THEM FOR ACCURACY, CONTRACTOR/HOMEOWNER MUST VERIFY GRAPES, FOOTING 51ZE5, ELEVATIONS, ROUGH OPENINGS, HEADER AND BEAM SIZES AND ALL OTHER DIMENSIONS AND 5PEC5 AN ESE RESPONSIBLE FOR THE SAME. SCALE AS SHOWN DRAWN BY J, JALOWITZ JOB NUMBER PAGE OF 3 m DOUBLE PORTAL FRAME SINGLE PORTAL FRAME PORTAL FRAME DETAIL 5RACING KEY PORTAL FRAME METHOD 6 OF COMM 21-25 (S) 1/2" DRYWALL W/ ALL EDGES BLOCKED 4 NAILED l" D.C. TO STUDS OR BLOCKING 6 ALL EDGES 4 12" O.C. IN FIELD (OR METAL T-WIND BRACING OR METHOD 4 SHOWN BELOW) METHOD 4 OF COMM 21,25 (8) 1/2" O,S,B, WALL SHEATHINGS NAILED TO STUDS 4 PLATES W/ SD SINKERS B T O.C, 0 ALL EDGES 4 12" O.C. IN FIELD BRACING NOTES 1.) WALLS INTERMITTENTLY BRACED W/ i/16" O.S.S. PANELS FASTENED W/ 8d NAILS Is 6" O.G. o PERIMETER 4 12" O.C. IN FIELD UNLESS NOTED OTHERWISE 2,) PLAN SHOWS MINIMUM PANELS REQUIRED FOR WALL SUPPORTING ROOF ONLY 4 MAXIMUM SPACINGS 15R4CING REQUIRED TO SUPPORT PERPENDICULAR WALL Vro PANELS MINIMUM g 25'-0" O.C. MAXIMUM 4 WITHIN 12'-ro" OF CORNER - 4 PANELS SHOWN 15'-81/41' 22'-10!/:2 15 _5,4ii -S/4 I I4'-5!/4 g'-0" �1 5 -�/4 12'-7 31-011 x 3'-6" 3'-0 1. x 31-611 3'-0" x 3,-6" 31-01, x 3'-611 m �-1-i V Z � z � � o LQ. ♦ n J _V Lu O tu u z � o � � O � O 3: Q � O U � o o � z � Q U ' DESIGN PHASE PRELIMINARY PLAN CHECK SET PLAN 4 APRIL 2025 FINAL CHECK SET PLAN 24 APRIL 2025 REVISION I REVISION 2 Ak- tP NOR 5VERY EFFORT HAS SEEN MADE IN PREPARING THESE PLAN5 AND CHECKINn THEM FOR ACCURACY, CONTRACTOR/HOMEOWNER MUST vERIFY GRADES, FOOTING SIZES, ELEVATIONS, ROUGH OPENINGS, HEADER AND BEAM SIZES AND ALL OTHER DIMENSIONS AND SPECS AN BE RESPONSIBLE FOR THE SAME, SCALE AS SHOWN DRAWN BY J. JALOWITZ Boa NUMBER PAGE 3 OF 3