Loading...
HomeMy WebLinkAbout006-439-09-1101-LUP-2025-063AI-I1I11 SITE NUMBER: Al N0265A SITE NAME: SBA-WI17647-A LOCATION MAP SITE LOCATION MAP DATA © 2024 GOOGLE T Mobile SBA SITE NUMBER: W117647-A-02 SBA SITE NAME: 191Z7_1:24:i PROJECT DESCRIPTION 1 NO NEW WATER OR SEWER IS REQUIRED AS FACILITY IS UNMANNED. EXISTING T-MOBILE BUILD OUT: (3) ANTENNAS, (3) RRU'S, (1) MW ANTENNA, (2) ODU'S, (2) MW CABLES, (2) OVP'S, (1) HCS, (2) AMOB'S, (2) CHAIR MOUNTS & (1) SITE SUPPORT CABINET FINAL T-MOBILE BUILD OUT: (3) ANTENNAS, (6) RRU'S, (1) MW ANTENNA, (2) ODU'S, (2) MW CABLES, (1) HCS 6x24 TRUNK, (1) SITE SUPPORT CABINET, (1) BBU CABINET & (2) AMIA'S IN SSC SCOPE -OF WORK: EXISTING (3) ANTENNA FRAMES TO REMAIN EXISTING (3) AHLOA'S TO REMAIN EXISTING (1) MW ANTENNA TO REMAIN EXISTING (2) ODU'S TO REMAIN EXISTING (2) MW CABLES TO REMAIN REMOVE (3) EXISTING ANTENNAS REMOVE (1) EXISTING OVP AT ANTENNAS REMOVE (1) EXISTING OVP AT GRADE REMOVE (1) EXISTING HIGH CAP HCS REMOVE (2) EXISTING AMOB'S RELOCATE (1) EXISTING ASIA CORE MODULE TO NEW AMIA REMOVE (1) EXISTING ASIK CORE MODULE RELOCATE (2) EXISTING ABIA CAPACITY MODULES TO NEW AMIA RELOCATE (1) EXISTING ABIL CAPACITY MODULE TO NEW AMIA REMOVE EXISTING FSEB INSTALL NEW FSEE REMOVE EXISTING PPC INSTALL NEW 225A PPC INSTALL NEW PLATFORM HANDRAIL SECTION INSTALL NEW PLATFORM STEP INSTALL NEW PLATFORM LIGHTS W/ TIMER REMOVE (2) EXISTING CHAIR MOUNTS REMOVE (1) EXISTING SITE SUPPORT CABINET INSTALL (3) NEW ANTENNAS (1 PER SECTOR) INSTALL (3) NEW AHFII'S (1 PER SECTOR) INSTALL (1) NEW HCS 6x24 TRUNK INSTALL (1) NEW SITE SUPPORT CABINET INSTALL (1) NEW BBU CABINET INSTALL (1) NEW AMIA WITH (1) ASIA CORE MODULE AND (3) ABIA CAPACITY MODULES INSTALL (1) NEW AMIA WITH (2) ASIL CORE MODULES AND (5) ABIL CAPACITY MODULES REMOVE EXISTING CSR 7705 SAR A INSTALL NEW CSR IXRe V2 JURISDICTION: SAWYER COUNTY SITE TYPE: SELF SUPPORT TOWER PROJECT TEAM WT GROUP, LLC. 2676 PRATUM AVENUE HOFFMAN ESTATES, IL 60192 CONTACT: TIM KUEN TEL: (224) 293-6333 FAX: (224) 293-6444 APPLICANT: T-MOBILE 1400 OPUS PLACE DOWNERS GROVE, IL 60515 TEL: (773) 4445400 CONTACT: T.B.D STRUCTURAL: GPD GROUP 520 SOUTH MAIN STREET, SUITE 2531 AKRON, OH 44311 TEL: (330) 572-2100 FAX: (330) 572-2101 SITE ADDRESS: 3803 W. WI STATE HIGHWAY 70 SITE ACQUISITION: SBA COMMUNICATION CORPORATION 8051 CONGRESS AVENUE BOCA RATON, FL 33487-1307 TEL: (800) 487-SITE (7483) TOWER OWNER: SBA COMMUNICATION CORPORATION 8051 CONGRESS AVENUE BOCA RATON, FL 33487-1307 TEL: (800) 487-SITE (7483) PROPERTY INFORMATION I SITE ADDRESS 3803 W. WI STATE HIGHWAY 70 DRAPER, WI 54896 TOWER INFORMATION STRUCTURE HEIGHT: 250'-0" SELF SUPPORT TOWER HIGHEST TOWER APPURTENANCE: T.B.D. T-MOBILE ANTENNA RAD CENTER: 231'-0" T-MOBILE ANTENNA TIP HEIGHT: 235'-0" COORDINATES (NAD 1983) LATITUDE: 45.802117' N LONGITUDE:-90.868340° W GROUND ELEVATION 1456.00' (PER GOOGLE EARTH) CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE FOLLOWING CODES: BUILDING CODE: ELECTRICAL CODE: 2015 WISCONSIN BUILDING CODE (2015 IBC) 2017 NATIONAL ELECTRICAL CODE (2017 NEC) DRAPER, WI 54896 SAWYER COUNTY SHEETINDEX SHEET NUMBER: DESCRIPTION: T-1 TITLE SHEET GN-1 GENERAL NOTES C-1 OVERALL SITE PLAN C-2 EXISTING & NEW SITE PLANS A-1 TOWER ELEVATION A-2 ANTENNA PLANS A-3 ANTENNA & CABLE SCHEDULE A-4 EQUIPMENT DETAILS A-5 EQUIPMENT DETAILS A-6 EQUIPMENT DETAILS A-7 EQUIPMENT DETAILS A-8 EQUIPMENT DETAILS A-9 EQUIPMENT DETAILS A-10 EQUIPMENT DETAILS A-11 EQUIPMENT DETAILS E-1 UTILITY PLAN E-2 ELECTRICAL DETAILS GRA GROUNDING RISER GR-2 GROUNDING DETAILS UTILITIES ELECTRIC: N/A CONTACT: N/A a TEL: N/A ! FIBER: N/A CONTACT: N/A KIIOIIIY111a11��I��AI. TEL: N/A Cellba�ale��y. REFERENCED MATERIALS A SITE WALK WAS NOT PERFORMED FOR THIS SITE PER SCOPE OF WORK. COMPOUND, ELEVATION, EQUIPMENT LAYOUT AND ANTENNA PLANS SHOWN WITHIN THIS SET WERE TAKEN FROM AVAILABLE DOCUMENTS/DRAWINGS PROVIDED BY OTHERS. CLI W ❑ s i . pm=4 ( $ pT LL1 O w 0 } C7 = Go U) L� cc M 0 m M �t11111117 �!S'% JEFF S. Tows 1 5Q9-{]OS EXPIRES:07/31126 SIGNED:01/27/25 REVISIONS REV, ISSUED FOR DATE BY A FORWENTREVIEW 12/1624 RAK 0 FINAL 01/27/25 TRK W�� w Z w cn 0 En ou, /z a g z �0/ a < z CHECK JKR EL U U cn DRAWN: RAK Z f U z v0i 0O - U JOB: T2400737 w ow/ / w J ~ Z m U L) z T-1 � = 0 f3?�U ¢ U a ¢ TITLE SHEET GENERAL REQUIREMENTS: 1.1 INTENT 1. THESE SPECIFICATIONS AND CONSTRUCTION DRAWINGS ACCOMPANYING THEM DESCRIBE THE WORK TO BE DONE AND THE MATERIALS TO BE FURNISHED FOR CONSTRUCTION. 2 THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE FULLY EXPLANATORY AND SUPPLEMENTARY. HOWEVER, SHOULD ANYTHING BE SHOWN, INDICATED OR SPECIFIED ON ONE AND NOT THE OTHER, IT SHALL BE DONE THE SAME AS IF SHOWN, INDICATED OR SPECIFIED IN BOTH- 3 THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS REASONABLY NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK AS STIPULATED IN THE CONTRACT. 4 THE PURPOSE OF THE SPECIFICATIONS IS TO INTERPRET THE INTENT OF THE DRAWINGS AND TO DESIGNATE THE METHOD OF THE PROCEDURE, TYPE AND QUALITY OF MATERIALS REQUIRED TO COMPLETE THE WORK. 5 MINOR DEVIATIONS FROM THE DESIGN LAYOUT ARE ANTICIPATED AND SHALL BE CONSIDERED AS PART OF THE WORK. NO CHANGES THAT ALTER THE CHARACTER OF THE WORK WILL BE MADE OR PERMITTED BY THE OWNER WITHOUT ISSUING A CHANGE ORDER. 1 2 CONFLICTS 1 THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL MEASUREMENTS AT THE SITE BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK. NO EXTRA CHARGE OR COMPENSATION SHALL BE ALLOWED DUE TO DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND DIMENSIONS INDICATED ON THE CONSTRUCTION DRAWINGS. ANY SUCH DISCREPANCY IN DIMENSION WHICH MAY BE FOUND SHALL BE SUBMITTED TO THE OWNER FOR CONSIDERATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK IN THE AFFECTED AREAS. 2 THE BIDDER, IF AWARDED THE CONTRACT, WILL NOT BE ALLOWED ANY EXTRA COMPENSATION BY REASON OF ANY MATTER OR THING CONCERNING WHICH SUCH BIDDER MIGHT HAVE FULLY INFORMED THEMSELVES PRIOR TO THE BIDDING. 3 NO PLEA OF IGNORANCE OF CONDITIONS THAT EXIST, OR OF DIFFICULTIES OR CONDITIONS THAT MAY BE ENCOUNTERED OR OF ANY OTHER RELEVANT MATTER CONCERNING THE WORK TO BE PERFORMED IN THE EXECUTION OF THE WORK WILL BE ACCEPTED AS AN EXCUSE FOR ANY FAILURE OR OMISSION ON THE PART OF THE CONTRACTOR TO FULFILL EVERY DETAIL OF ALL THE REQUIREMENTS OF THE CONTRACT DOCUMENTS GOVERNING THE WORK. 1.3 CONTRACTS AND WARRANTIES 1, CONTRACTOR IS RESPONSIBLE FOR APPLICATION AND PAYMENT OF CONTRACTOR LICENSES AND BONDS 14STORAGE 17 ALL MATERIALS MUST BE STORED IN A LEVEL AND DRY FASHION AND IN A MANNER THAT DOES NOT NECESSARILY OBSTRUCT THE FLOW OF OTHER WORK. ANY STORAGE METHOD MUST MEET ALL RECOMMENDATIONS OF THE ASSOCIATED MANUFACTURER. 2. THE BTS MUST BE STORED INSIDE UNTIL THERE IS POWER ON SITE. 1.5 CLEAN UP 1. THE CONTRACTORS SHALL AT ALL TIMES KEEP THE SITE FREE FROM ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED BY THEIR EMPLOYEES AT WORK AND AT THE COMPLETION OF THE WORK, THEY SHALL REMOVE ALL RUBBISH FROM AND ABOUT THE BUILDING AREA, INCLUDING ALL THEIR TOOLS, SCAFFOLDING AND SURPLUS MATERIALS AND SHALL LEAVE THEIR WORK CLEAN AND READY FOR USE. 2 EXTERIOR: VISUALLY INSPECT EXTERIOR SURFACES AND REMOVE ALL TRACES OF SOIL, WASTE MATERIALS, SMUDGES AND OTHER FOREIGN MATTER. A REMOVE ALL TRACES OF SPLASHED MATERIALS FROM ADJACENT SURFACES B. IF NECESSARY TO ACHIEVE A UNIFORM DEGREE OF CLEANLINESS, HOSE DOWN THE EXTERIOR OF THE STRUCTURE. 3. INTERIOR: VISUALLY INSPECT INTERIOR SURFACE AND REMOVE ALL TRACES OF SOIL, WASTE MATERIALS, SMUDGES AND OTHER FOREIGN MATTER FROM WALLS/FLOOR/CEILING. A. REMOVE ALL TRACES OF SPLASHED MATERIAL FROM ADJACENT SURFACES. B. REMOVE PAINT DROPPINGS, SPOTS, STAINS AND DIRT FROM FINISHED SURFACES. 1.6 CHANGE ORDER PROCEDURE 1 CHANGE ORDERS MAY BE INITIATED BY THE OWNER AND/OR THE CONTRACTOR INVOLVED. THE CONTRACTOR, UPON VERBAL REQUEST FROM THE OWNER HALL PREPARE A WRITTEN PROPOSAL DESCRIBING THE S OS CHANGE IN WORK OR MATERIALS AND ANY CHANGES IN THE CONTRACT AMOUNT AND PRESENT TO THE OWNER WITHIN 72 HRS FOR APPROVAL. SUBMIT REQUESTS FOR SUBSTITUTIONS IN THE FORM AND IN ACCORDANCE WITH PROCEDURES REQUIRED FOR CHANGE ORDER PROPOSALS. ANY CHANGES IN SCOPE OF WORK OR MATERIALS WHICH ARE PERFORMED BY THE CONTRACTOR WITHOUT A WRITTEN CHANGE ORDER AS DESCRIBED AND APPROVED BY THE OWNER SHALL PLACE FULL RESPONSIBILITY OF THESE ACTIONS ON THE CONTRACTOR. 1.7 RELATED DOCUMENTS AND COORDINATION 1. GENERAL CARPENTRY, ELECTRICAL AND ANTENNA DRAWINGS ARE INTERRELATED. IN PERFORMANCE OF THE WORK, THE CONTRACTOR MUST REFER TO ALL DRAWINGS. ALL COORDINATION TO BE THE RESPONSIBILITY OF THE CONTRACTOR. 1.8 SHOP DRAWINGS 1. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUIRED AND LISTED IN THESE SPECIFICATIONS TO THE OWNER FOR APPROVAL 2 ALL SHOP DRAWINGS SHALL BE REVIEWED, CHECKED AND CORRECTED BY CONTRACTOR PRIOR TO SUBMITTAL TO THE OWNER 1.9 PRODUCTS AND SUBSTITUTIONS 1. SUBMIT 3 COPIES OF EACH REQUEST FOR SUBSTITUTION. IN EACH REQUEST IDENTIFY THE PRODUCT OR FABRICATION OR INSTALLATION METHOD TO BE REPLACED BY THE SUBSTITUTION. INCLUDE RELATED SPECIFICATION SECTION AND DRAWING NUMBERS AND COMPLETE DOCUMENTATION SHOWING COMPLIANCE WITH THE REQUIREMENTS FOR SUBSTITUTIONS. 2 SUBMIT ALL NECESSARY PRODUCT DATA AND CUT SHEETS WHICH PROPERLY INDICATE AND DESCRIBE THE ITEMS, PRODUCTS AND MATERIALS BEING INSTALLED. THE CONTRACTOR SHALL, IF DEEMED NECESSARY BY THE OWNER SUBMIT ACTUAL SAMPLES TO THE OWNER FOR APPROVAL IN LIEU OF CUT SHEETS 1.10 QUALITY ASSURANCE 1. ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS. 1 11 ADMINISTRATION 1. BEFORE THE COMMENCEMENT OF ANY WORK, THE CONTRACTOR WILL ASSIGN A PROJECT MANAGER WHO WILL ACT AS A SINGLE POINT OF CONTACT FOR ALL PERSONNEL INVOLVED IN THIS PROJECT. THIS PROJECT MANAGER WILL DEVELOP A MASTER SCHEDULE FOR THE PROJECT WHICH WILL BE SUBMITTED TO THE OWNER PRIOR TO THE COMMENCEMENT OF ANY WORK. 2 SUBMIT A BAR TYPE PROGRESS CHART NOT MORE THAN 3 DAYS AFTER THE DATE ESTABLISHED FOR COMMENCEMENT OF THE WORK ON THE SCHEDULE, INDICATING A TIME BAR FOR EACH MAJOR CATEGORY OR UNIT OF WORK TO BE PERFORMED AT SITE, PROPERLY SEQUENCED AND COORDINATED WITH OTHER ELEMENTS OF WORK AND SHOWING COMPLETION OF THE WORK SUFFICIENTLY IN ADVANCE OF THE DATE ESTABLISHED FOR SUBSTANTIAL COMPLETION OF THE WORK. 3 PRIOR TO COMMENCING CONSTRUCTION, THE OWNER SHALL SCHEDULE AN ON -SITE MEETING WITH ALL MAJOR PARTIES. THIS WOULD INCLUDE (THOUGH NOT LIMITED TO) THE OWNER, PROJECT MANAGER, CONTRACTOR, LAND OWNER REPRESENTATIVE, LOCAL TELEPHONE COMPANY, TOWER ERECTION FOREMAN (IF SUBCONTRACTED). 4 CONTRACTOR SHALL BE EQUIPPED WITH SOME MEANS OF CONSTANT COMMUNICATIONS, SUCH AS A MOBILE PHONE OR A BEEPER. THIS EQUIPMENT WILL NOT BE SUPPLIED BY THE OWNER, NOR WILL WIRELESS SERVICE BE ARRANGED. 5 DURING CONSTRUCTION, CONTRACTOR MUST ENSURE THAT EMPLOYEES AND SUBCONTRACTORS WEAR HARD HATS AT ALL TIMES. CONTRACTOR WILL COMPLY WITH ALL SAFETY REQUIREMENTS IN THEIR AGREEMENT 6. PROVIDE WRITTEN DAILY UPDATES ON SITE PROGRESS TO THE OWNER. 7 COMPLETE INVENTORY OF CONSTRUCTION MATERIALS AND EQUIPMENT IS REQUIRED PRIOR TO START OF CONSTRUCTION. 8. NOTIFY THE OWNER / PROJECT MANAGER IN WRITING NO LESS THAN 48 HOURS IN ADVANCE OF CONCRETE POURS, TOWER ERECTIONS, AND EQUIPMENT CABINET PLACEMENTS. 1.12INSURANCE AND BONDS 1. CONTRACTOR SHALL AT THEIR OWN EXPENSE CARRY AND MAINTAIN FOR THE DURATION OF THE PROJECT ALL INSURANCE AS REQUIRED AND LISTED AND SHALL NOT COMMENCE WITH THEIR WORK UNTIL THEY HAVE PRESENTED AN ORIGINAL CERTIFICATE OF INSURANCE STATING ALL COVERAGES TO THE OWNER. REFER TO THE MASTER AGREEMENT FOR REQUIRED INSURANCE LIMITS. 2 THE OWNER SHALL BE NAMED AS AN ADDITIONAL INSURED ON ALL POLICIES. 3 CONTRACTOR MUST PROVIDE PROOF OF INSURANCE. ANTENNA INSTALLATION: 1.1 REQUIREMENTS OF REGULATOR AGENCIES 1. FURNISH U.L LISTED EQUIPMENT WHERE SUCH LABEL IS AVAILABLE, INSTALL IN CONFORMANCE WITH U.L. STANDARDS WHERE APPLICABLE. 2. INSTALL ANTENNA, ANTENNA CABLES, GROUNDING SYSTEM IN ACCORDANCE WITH DRAWINGS AND SPECIFICATION IN EFFECT AT PROJECT LOCATION AND RECOMMENDATIONS OF STATE AND LOCAL BUILDING CODES, SPECIAL CODES HAVING JURISDICTION OVER SPECIFIC PORTIONS OF WORK. THIS INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: A TIA - TELECOMMUNICATIONS INDUSTRY ASSOCIATION TIA-222-G. STRUCTURAL STANDARDS FOR STEEL ANTENNA TOWERS AND ANTENNA SUPPORTING STRUCTURES. B. FAA - FEDERAL AVIATION ADMINISTRATION ADVISORY CIRCULAR AC 70f7460-IH, OBSTRUCTION MARKING AND LIGHTING. C. FCC - FEDERAL COMMUNICATIONS COMMISSION RULES AND REGULATIONS FORM 715, OBSTRUCTION MARKING AND LIGHTING SPECIFICATIONS FOR ANTENNA STRUCTURES AND FORM 715A, HIGH INTENSITY OBSTRUCTION LIGHTING SPECIFICATIONS FOR ANTENNA STRUCTURES D. AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. E. NEC - NATIONAL ELECTRICAL CODE - ON TOWER LIGHTING KITS. F. UL - UNDERWRITER'S LABORATORIES APPROVED ELECTRICAL PRODUCTS. G. IN ALL CASES, PART 77 OR THE FAA RULES AND PARTS 17 AND 22 OF THE FCC RULES ARE APPLICABLE AND IN THE EVENT OF CONFLICT, SUPERSEDE ANY OTHER STANDARDS OR SPECIFICATIONS. H. 2012 LIFE SAFETY CODE NFPA -101, GENERAL ELECTRIC PROVISION: 1 SUBMITTAL OF BID INDICATES CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PERFORMED UNDER THIS CONTRACT. 2 CONTRACTOR SHALL PERFORM ALL VERIFICATION OBSERVATIONS TEST, AND EXAMINATION WORK PRIOR TO THE ORDERING OF THE ELECTRICAL EQUIPMENT AND THE ACTUAL CONSTRUCTION. CONTRACTOR SHALL ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE ARCHITECT LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. 3 EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED IN EACH PANEL BOARD, PULL BOX, J-BOX, SWITCH BOX, ETC., IN COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ACT (O.S.H.A.). 4. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, INSURANCE, EQUIPMENT, INSTALLATION, CONSTRUCTION TOOLS, TRANSPORTATION, ETC., FOR A COMPLETE AND PROPERLY OPERATIVE SYSTEM ENERGIZED THROUGHOUT AND AS INDICATED ON DRAWINGS, AS SPECIFIED HEREIN AND/OR AS OTHERWISE REQUIRED. 5 ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED AND SHALL BE OF THE BEST GRADE AND OF THE SAME MANUFACTURER THROUGHOUT FOR EACH CLASS OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED "J" WHERE SUBJECT TO SUCH APPROVAL. MATERIALS SHALL MEET WITH APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY ANSI, NEMA AND NBFU. 6 ALL CONDUIT INSTALLED SHALL BE SURFACE MOUNTED OR DIRECT BURIAL UNLESS OTHERWISE NOTED. 7. CONTRACTOR SHALL CARRY OUT THEIR WORK IN ACCORDANCE WITH ALL GOVERNING STATE, COUNTY AND LOCAL CODES AND O.S.H.A. 8 CONTRACTOR TO OBTAIN ALL PERMITS, PAY PERMIT FEES, AND BE RESPONSIBLE FOR SCHEDULING INSPECTIONS. 9 COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF JOB ACCEPTANCE BY OWNER. ANY WORK, MATERIAL OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE, UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE CONTRACTOR. 10 ALL CONDUIT SHALL HAVE A PULL WIRE OR ROPE. 11 PROVIDE PROJECT MANAGER WITH ONE SET OF COMPLETE ELECTRICAL "AS INSTALLED" DRAWINGS AT THE COMPLETION OF THE JOB, SHOWING ACTUAL DIMENSIONS, ROUTINGS AND CIRCUITS. 12. ALL BROCHURES, OPERATING MANUALS, CATALOGS, SHOP DRAWINGS, ETC., SHALL BE TURNED OVER TO THE OWNER AT JOB COMPLETION. 13, USE T-TAP CONNECTIONS ON ALL MULTI -CIRCUITS WITH COMMON NEUTRAL CONDUCTOR FOR LIGHTING FIXTURES 14 ALL CONDUCTORS SHALL BE COPPER. 15 ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED, AND A MINIMUM OF 10,000 A.I.C. 16, THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS REQUIRED BY ALL APPLICABLE CODES. 17. PATCH, REPAIR AND PAINT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF THE ELECTRICAL WORK. 18. PENETRATIONS IN FIRE RATED WALLS SHALL BE FIRE STOPPED IN ACCORDANCE WITH APPLICABLE LOCAL BUILDING CODES. I WIRE AND CABLE CONDUCTORS SHALL BE COPPER #12 AWG MINIMUM UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS, 2Q GROUNDING CONDUCTORS SHALL BE SOLID TINNED COPPER UNLESS OTHERWISE NOTED. 21. ALL MATERIALS SHALL BE U.L. LISTED. 22. CONDUIT A. RIGID CONDUIT SHALL BE U.L. LABEL GALVANIZED ZINC COATED WITH ZINC INTERIOR AND SHALL BE USED WHEN INSTALLED IN OR UNDER CONCRETE SLABS IN CONTACT WITH THE EARTH, UNDER PUBLIC ROADWAYS, IN MASONRY WALLS OR EXPOSED ON BUILDING EXTERIOR. RIGID CONDUIT IN CONTACT WITH EARTH SHALL BE 112 LAPPED WRAPPED WITH HUNTS WRAP PROCESS NO. 3 B. ELECTRICAL METALLIC TUBING SHALL HAVE U.L. LABEL, FITTING SHALL BE GLAND RING COMPRESSION TYPE. EMT SHALL BE USED ONLY FOR INTERIOR RUNS. C. FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L. LISTED LABEL AND MAY BE USED WHERE PERMITTED BY CODE. FITTINGS SHALL BE "JAKE" OR "SQUEEZE" TYPE, SEAL TIGHT FLEXIBLE CONDUIT. ALL CONDUIT SHALL HAVE FULL SIZE EQUIPMENT GROUND WIRE. D. CONDUIT RUNS SHALL BE SURFACE MOUNTED UNLESS INDICATED OTHERWISE CONDUIT INDICATED SHALL RUN PARALLEL OR AT RIGHT ANGLES TO CEILING, FLOOR OR BEAMS VERIFY EXACT ROUTING OF ALL EXPOSED CONDUIT WITH THE OWNER PRIOR TO INSTALLING. NO HORIZONTAL CONDUITS SHALL BE BELOW T-WA.F.F. NO BX OR ROMEX CABLE IS PERMITTED. E PARALLEL UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40 (UNLESS NOTED OTHERWISE) AT A MINIMUM DEPTH OF 3W BELOW GRADE - STACKED UNDERGROUND CONDUIT SHALL BE PVC SCHEDULE 40 (UNLESS NOTED OTHERWISE) AT A MINIMUM DEPTH OF 24" BELOW GRADE F, ABOVE GROUND CONDUIT SHALL BE P.V.C. SCHEDULE 80 (UNLESS NOTED OTHERWISE). 23. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED WITH PERMANENT ENGRAVED PLASTIC LABELS. 24. UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALL OF POTENTIAL GROUND TESTS FOR APPROVAL SUBMIT TEST REPORTS TO PROJECT MANAGER. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDITION. ` 8 � ® D; H � O ao 0) •rl U� � � s O n } 2 = ro W co Lf) ~� � co A S W a CD 3M C, g cq O m M Z Q �Sti 11ry'��� VV iv/A `rrf JEFF S. '� ITOWSkY f = EXPIRES D7/31128 SIGNE➢:01127I25 REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 12/1624 RAK 0 FINAL 012725 TRK z J (J J W U Z L z w F- oI>w= LU u a U) Z z z g / O / C7 r Q Q J Z d Z U Z U Z O J O W J / J_ U F- Z m O U U 0- Q CHECK: JKR nQAVM- RAK JOB: 124UU/3( GN-1 GENERALNOTES GENERAL SITE NOTES: 1, CONTRACTOR WILL NOT START CONSTRUCTION UNTIL AFTER THEY HAVE RECEIVED THE PRE -CON PACKAGE AND HAVE A PRE -CON WALK WITH THE PROJECT MANAGER. 2. CONTRACTOR TO HIRE PUBLIC (811) AND PRIVATE LOCATING SERVICE IN ORDER TO LOCATE AND PROTECT ALL SURFACE UTILITIES. DO NOT SCALE OFF THESE PLANS FOR ANY BELOW GRADE UTILITIES 3 CONTRACTOR SHALL VERIFY ALL EXISTING BURIED AND OVERHEAD UTILITIES PRIOR TO EXCAVATION. CONTRACTOR SHALL REPAIR ALL DAMAGED UTILITIES AT HIS OWN COST AND COORDINATE ANY REPAIRS WITH RESPECTIVE UTILITY COMPANY. 4 CONTRACTOR TO VERIFY ALL HEIGHTS AND AZIMUTHS IN FIELD PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY T-MOBILE AND ENGINEERING FIRM OF ANY DISCREPANCIES BEFORE PROCEEDING. 5 CONTRACTOR SHALL RESTORE AND REPAIR ANY DAMAGED AREAS CAUSED BY CONSTRUCTION. � � s _ter �~'� '- �, Sf� 3 " .� y.�I' �•� i �.�L��- �+7 ]'►.n ' � f! � X ■. f r Av 4 ow 412: GRASS IIII "or, r f ewe. air- 10 ING 1 r _� �.` M17 ep NCE OVERALL SITE PLAN SCALE: 1" = 120'-0" Pro, 3 � 0 1 1LLB J �a E 0PE1 CDT imp O Fm=4 rb C, w co 2 = 'IT 4. ~ S L0 A cd n co UJI co(L O mm C4 c') a- ,�Itlll!lllfl r' JEFF S. '�+ r ITOWSKY * : � �J.[3tJfi � % �IllllTt�t EXPIRES:0713i126 SIGNED 01127M REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 1211624 RAK 0 FINAL 012725 TRK W U Z K fzwp '_ �w=WD Z g ' z �o/ UO ¢ J Z CHECK: JKR a Z m = U DRAWN: RAK N MO uj U — JOB: T2400737 w J / J_ ~ m 1/mw U ? C-1 J U U a ¢ OVERALL SITE PLAN (1) EXISTING HIGH CAP HCS TO BE REMOVED r (2) EXISTING MW CABLES TO RELIAII1- EXISTING FSEB TO BE REMOVED EXISTING OVP TO BE REMOVED MODULES ON CHAIR MOUNTS: REMOVE (2) EXISTING AMOB'S RELOCATE (1) EXISTING ASIA CORE MODULE TO NEW AMIA REMOVE (1) EXISTING ASIK CORE MODULE - RELOCATE (2) EXISTING ABIA CAPACITY MODULES TO NEW AMIA RELOCATE (1) EXISTING ABIL CAPACITY MODULE TO NEW AMIA REMOVE EXISTING CHAIR MOUNTS EXISTING FIBER ENCLOSURE — LEGEND THE FOLLOWING EQUIPMENT IS TO BE INSTALLED IN THE NEW SITE SUPPORT F EXISTING EQUIPMENT CABINET: CSR IXRe V2 _(1) NEW/MODIFIED EQUIPMENT - (1) FSEE (1) VOLTAGE BOOSTER REMOVED EQUIPMENT (1) SPD TRAY (1) FIBER PATCH/TRAY COMBO RELOCATED EQUIPMENT EXISTING SITE SUPPORT CABINET TO BE REMOVED (REMOVE CSR 7705 SAR A) EXISTING T-MOBILE EQUIPMENT PLATFORM IPH CANOPY I i I I I NEC CLEARANCE I I I I I L J EXISTING PPC TO BE REMOVED EXISTING FYGA GPS ANTENNA EXISTING EQUIPMENT PLAN _ SCALE: 3/8" = V-0" 4 NEW SB3 BATTERY CABINET TO BE INSTALLED. SEE A-10- NEW CABINET SUPPORT TO BE INSTALLED (TYP.). SEE 3/A-7 — (1) NEW HCS 6x24 TRUNK TO BE INSTALLED (2) EXISTING 6AVV 9 CABLES TO REMAIN NEW HD LED SAFETY LIGHT V1ATH TIMER TO BE INSTALLED 4 (TYP. OF 2). SEE 2&3IE-2 - I I r�� T I I I l I I I MODULES INSIDE SITE SUPPORT CABINET: • (1) NEW AMIA WITH (1) ASIA CORE MODULE AND (3) ABIA CAPACITY MODULES • (1) NEW AMIA WITH (2) ASIL CORE MODULES AND (5) ABIL CAPACITY MODULES (1) NEW BSP 126 SUPPORT POST FOR 6X24 TRANSITION TO CANOPY SUPPORT EXISTING FIBER ENCLOSURE — NOTES: 1. (1) NEW HCS 6X24 TRUNK TO FEED (3) EXISTING AHLOA'S & (3) NEW AHFII'S NOTE: WPS SCOPE OF WORK DOES NOT INCLUDE A STRUCTURAL ANALYSIS OF THE EQUIPMENT PLATFORM. NEW EQUIPMENT SHOWN ON THIS PLAN HAVE NOT BEEN EVALUATED TO VERIFY THE PLATFORM HAS THE CAPACITY TO ADEQUATELY SUPPORT THE CABINETS/EQUIPMENT, PRIOR TO ANY EQUIPMENT INSTALLATION, A STRUCTURAL EVALUATION OF THE EQUIPMENT PLATFORM, INCLUDING ALL EQUIPMENT CABINET SUPPORT BRACING & HARDWARE SHALL BE PERFORMED. NOTE: ROUTE ALL CONDUITS UNDER PLATFORM GRATING TRAPEZED AS HIGH AS POSSIBLE EXISTING T-RAOBILE EQUIPMENT PLATFORM W/ CANOPY NEW (2) LEVELS OF HANDRAIL FROM CANOPY POST TO CANOPY POST �. NEW PLATFORM ACCESS STEPS TO BE INSTALLED (PERFECT VISION PART# PV-EQ-STEP1). SEE 2/G-7 i i I I I I UQ I f wM ZU I I f I lk �NLW 225A PPC TO BE INSTALLED. SEE A-11 NEW HPL3.05 SITE EXISTING FI SUPPORT CABINET TO CPS ANTENNA BE INSTALLED. SEE A-9: • NEW CSR IXRe V2 • NEW FSEE go�yy Ell MOIL O i ■ 0 r` 2 C7 H v Lc) CD M C W I. �W [/ to to 3 M No Q m O m M Q N `illl�lrr�, JEFF S. ITOWSKY :*= rrr�10O11`8i EXPIRES: 07/31/26 SIGNED:01/27/25 REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 12116/24 RAK 0 FINAL 012725 TRK F J (, J N w��� �zL! LD Z W 2�o� g ' � oz / 0 O Q J Z CHECK: JKR ,3 M Hen DRAWN: RAK 92 O L) JOB: T2400737 w � J / NEW EQUIPMENT PLAN ' w J ~ ? m U 2 p/m� C-2 SCALE: 3/8" = V-0" S) > � 0 EXISTING & U a ¢ NEW SITE PLANS I■-I!rrl!!l\I11111 EXISTING EQUIPMENT ® NEW EQUIPMENT REMOVED EQUIPMENT RELOCATED EQUIPMENT IMPORTANT SITE NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FINAL RF CONFIGURATION AND NOTIFY T-MOBILE AND ENGINEERING FIRM WITH ANY DISCREPANCIES. 2, CONTRACTOR SHALL VERIFY ALL FINAL CONNECTION LOCATIONS WITH T-MOBILE ENGINEER, RF ENGINEER, AND NET-OPS PRIOR TO INSTALLATION. 3, CONTRACTOR TO USE PROPER TORQUE WRENCH WHEN INSTALLING AND TIGHTENING CONNECTORS TO INSURE PROPER FIT. 4. CONTRACTOR TO ARRANGE NEW MODULES/EQUIPMENT TO AVOID INTERFERING WITH SAFETY CLIMB. IRU'S. SEE A-2 3) :NA & ODU'S NOTE: A STRUCTURAL ANALYSIS OF THE TOWER OR STRUCTURE HAS BEEN COMPLETED BY GPD GROUP ON NOVEMBER 06, 2024. THE LOCATION AND MOUNTING SHOWN IN THE STRUCTURAL ANALYSIS SHALL SUPERSEDE THESE DRAWINGS. NOTE: A STRUCTURAL ANALYSIS OF THE ANTENNA MOUNT HAS BEEN COMPLETED BY GPD GROUP ON NOVEMBER 05, 2024. THE LOCATION AND MOUNTING SHOWN IN THE MOUNT ANALYSIS SHALL SUPERSEDE THESE DRAWINGS. NOTE: ANTENNA CENTERLINE'S VERTICAL OFFSET FROM PLATFORM DECK OR HORIZONTAL CENTER OF SECTOR FRAME SHALL NOT EXCEED 6". TOWER ELEVATION SCALE: 1" = 30'-0" 1 ` G � >3 wo 4� O' yLLo ~ a � O / w ■ 0 } 2 x m w a F ri M a N ^ w CIL 04 C3 o m w Z U) a �yJill 11" JEFF S ITQWSkY *" I Sb9�iv +� s`��O1fAL �i'� ,1*0011111� EXPIRES:07131/26 SiONED:01127125 REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 12/16/24 RAK 0 FINAL 01/27/25 TRK U Z w � z w r LLI a > U U S 0_ Z W 7 u! F Z N ¢z3i moo, o Q < Z CHECK' JKR a V U 7 K w DRAWN: RAK z i U z NO w U w JOB: T2400737 w o w J J i w ~ m U ? ' m w A-1 � J � U C, ¢ U a ¢ TOWER ELEVATION EXISTING AHLOA TO REMAIN (TYP OF 1 PER SECTOR) EXISTING ANTENNA FRAME TO REMAIN (TYP, OF 3) EXISTING ANTENNA TO BE REMOVED — GAMMA = 240° ALPHA = 0° I EXISTING ANTENNA TO BE REMOVED EXISTING OVP TO BE REMOVED EXISTING ANTENNA TO BE REMOVED BETA = 120" EXISTING ANTENNA PLAN SCALE:NONE LEGEND EXISTING EQUIPMENT NEW EQUIPMENT REMOVED EQUIPMENT RELOCATED EQUIPMENT N JUMPER LENGTH'S • AHLOA ALPHA: 15'-0" BETA: 30'-0" GAMMA: 30'-0" • AHFII -ALPHA: 1 S-0" BETA: 30'-0" GAMMA: 30'-0" NOTE: EXISTING AHLOA RRU'S WILL NEED NEW JUMPERS FOR THE NEW 6X24 HCS TRUNK. NEW FFVV-65C-R2N23 ANTENNA TO BE INST, GAMMA = 240' EXISTING ANTENNA FRAME TO REMAIN (TYP OF 3) EXISTING .AHLOA TO REMAIN (TYP OF 1 PER SECTOR) — NEW HCS 6X24 TRUNK TO BE INSTALLED -- ALPHA = 0° I NOTE: A STRUCTURAL ANALYSIS OF THE TOWER OR STRUCTURE HAS BEEN COMPLETED BY GPD GROUP ON NOVEMBER OB, 2024. THE LOCATION AND MOUNTING SHOWN IN THE STRUCTURAL ANALYSIS SHALL SUPERSEDE THESE DRAWINGS. NOTE: A STRUCTURAL ANALYSIS OF THE ANTENNA MOUNT HAS BEEN COMPLETED BY GPD GROUP ON NOVEMBER 05, 2024. THE LOCATION AND MOUNTING SHOWN IN THE MOUNT ANALYSIS SHALL SUPERSEDE THESE DRAWINGS. NOTE: ANTENNA INFORMATION OBTAINED FROM T-MOBILE RF DATA CONFIGURATION SHEET DATED 09/24/24, NEW FFVV-65C-R2N23 ANTENNA TO BE INSTALLED NEW AHFII TO BE INSTALLED (TYP. OF 1 PER SECTOR) NEW ANTENNA PLAN SCALE: NONE NEW FFW-65C-R2N23 ANTENNA TO BE INSTALLED BETA = 120' a >a 4� o6 O Eno%' 0 Y S 2 � W a co F A H 3 3 a rmcl) L��Ji ��111111��, JEFF S •�1� ITOWSKY 509-am EXPIRES. C7131M 51GNED. 01127F25 REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 12116/24 RAK 0 FINAL 012725 TRK N Zw 6z9 � f z w r M w p t~i f z �Z5� o� p Q z7ANJTENNA QJQ q! Z N 0O Lu U w J J V ~ Z LU 2 m�¢ U a ¢ (3) WRAPS OF INSULATION TAPE (OVERLAPPING 50%) ANTENNA & CABLE SCHEDULE SECTOR ALPHA BETA GAMMA LOCATION A-1 B-1 C-1 TECHNOLOGY LTE 600, LTE 700. N600, LTE PCS, LTE AWS, LAWS3, N1900, N2100 LTE 600, LTE 700, N600, LTE PCS, LTE AWS, LAWS3, N1900,N2100 LTE 600. LTE 700, N600, LTE PCS, LTE AWS, LAWS3, N1900, N2100 AZIMUTH 0• 120° 240° RAD CENTER 231'-0" 231'-0" 231'-0" COLOR CODING (SEE CHART ON A-4) MODEL# COMMSCOPE FFW-65C-R2N23 (OCTO) COMMSCOPE FFW-65C-R2N23 (OCTO) COMMSCOPE FFW-65C-R2N23 (OCTO) MECHANICAL DOWNTILT 0 0 0 ELECTRICAL DOWNTILT 2.2.2.2 2.2.2.2 2.2.2.2 RRU TYPE AHFII / AHLOA AHFII / AHLOA AHFII / AHLOA HCS DIA. &TYPE HCS 6x24 TRUNK (1 OF 1) SHARED HCS 6x24 TRUNK (1 OF 1) SHARED HCS 6x24 TRUNK (1 OF 1) HCS ACTUAL LENGTH t250'-0" HCS FACTORY LENGTH 275'-0" NEW HCS 6x24 ACTUAL ACTUALLENGTH FACTORY NOTE: TRUNK LENGTH *10°SAFETY NEW LENGTH FAACTOR LENGTH HCS 6x24 JUMPERS TO BE ORDERED IN 5M, 10M, OR 20M LENGTHS. FROM SSC TO ANTENNA LOCATION t250'-0" ±275'-0" 275'-0" JUMPERS TO BE TORQUED TO 221.27 IN/LBS CABLE TIE 50MM , , 20MM (1) WRAP OF INSULATION TAPE (OVERLAPPING 50%) (2) STRETCH WRAPPED WRAPS OF SELF AMALGAMATING TAPE (STRETCH 30%, OVERLAPPING 50%) RF JUMPER CONNECTION DETAIL SCALE:NONE F NEW TOWER STANDOFF KIT. SITE PRO PART # STK3 (2) NEW BARREL CUSHIONS. SITE PRO PART # BC124 —� NEW COAX BLOCK MOUNTING HARDWARE. SITE PRO PART# CH50- NEW COAX BLOCK. SITE PRO PART # NOTE: A STRUCTURAL ANALYSIS OF THE TOWER OR STRUCTURE HAS BEEN COMPLETED BY GPD GROUP ON NOVEMBER 08, 2024. THE LOCATION AND MOUNTING SHOWN IN THE STRUCTURAL ANALYSIS SHALL SUPERSEDE THESE DRAWINGS. NOTE: A STRUCTURAL ANALYSIS OF THE ANTENNA MOUNT HAS BEEN COMPLETED BY GPD GROUP ON NOVEMBER 05, 2024. THE LOCATION AND MOUNTING SHOWN IN THE MOUNT ANALYSIS SHALL SUPERSEDE THESE DRAWINGS. NOTE: ANTENNA INFORMATION OBTAINED FROM T-MOBILE RF DATA CONFIGURATION SHEET DATED 09124/24. ANTENNA & CABLE SCHEDULE SCALE: NONE EXISTING MOUNTING PIPE RF JUMPER MOUNTING DETAIL SCALE: NONE 1 m 8 $ 3 P4 E1 jL � S O 5` i Emm!4 0 Y 2 Ui 2 � rn a �Lo n LU cm 0 M O m coGo z N a r •. r tf JEFF S..�titi2 TOWSKY I�*.,�'�� ti �••w..r�`ti� ►►�l1lll��y EINIRI S: 0713112& SIGNED- OV27125 REVISIONS REV ISSUED FOR DATE BY A FOR CLIENT REVIEW 12/1624 RAK 0 FINAL 01/2725 TRK Lu � z qa Lu L) 0 w ❑ �� ❑cn u~i z 15 z LD 0 Z CHECK JKR a U U ca K N F DRAWN: RAK NO - U w JOB: T2400737 W w W J J � W U ~ z m m� r2 A-3 Q W O > U ANTENNA & L) a ¢ CABLE SCHEDULE _ ►iCS 6x2/ (1 of FHior Pair Idontifiration TDp of Town Bottom of lower Comments Trunk ■ Fiber Pair Bundle Color Sector RF Module RF Port System Module BB Port Technolony 1 None Ajpha AHFI11 OPT1 1 None Aiphs AHFIII OPT2 1 None 1 4 None AI ha AHFIII OPTS 1 5 None Alpha AHLOBI OPT1 1 None AJpha AHLOBI OPT2 1 White Bela AHFII2 OPT1 1 White Bela AHFII2 OPT2 1 Whlte 1 10 While Beta AHFII2 OPT3 1 11 White Bela AHLOB2 OPT1 1 White Beta AHLOB2 OPT2 7 1 1 1 16 AHF113 AHF113 AHF113 OPT1 OPT2 OPT3 _ ► 1 17 1 1 I AHLO83 AHLOB3 OPT7 OPT 1 22 Vv- 1 23 J NOTE: CABLE COLOR CODING ON THIS SHEET IS PRELIMINARY AND PENDING FINAL COLOR CODING DESIGN FROM CARRIER. Kcs Wtlf (1 OF 2) DC Pair Color Sector RF Module HCS Trunk Length Where Booster Required 1 Alpha AHFIII All HCS trunk lengths Beta AHFII2 All HCS trunk len the Gamma AHF113 All HCS trunk lengths 1 Yellow I Alpha AHLOBI For 00m and longer , White Beta AHLOB2 For 80m and longer 1 Gamma AHLB03 For 80m and longer HCS 6x24 COLOR CODING SCALE:NONE >n o g A i m u Q� O- qLL� E8 L •�..j Cam aim ■ n } S = m W L0H Q Q rn W EL r Z to a 1111111r■ .� 00Av ' JEFF Irtows�v * = S49•DUBi- EXPIRES: 0113 1126 SIGNED: 0 112 712 5 REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 1211624 RAK e FINAL 012725 TRK z J z J U Y w 0rc� U 7 in r z w ¢zg' moo/ 0< IL U O J z w o U) U w L) w ❑ w / J J / w U ~ z m F / m y C, ? U 6 U a 6 Configuration f 790A H{ jFr#7 / ,# ` for SG and LTE Airscale B8 dfinensioning refer to Fiber Port matrices. (Alpha, Beta & Gamma) 1w .01ri I -at Na Otto Passive Antenna FDD - Lnwband ' 812 (L700) - S MHz u9 871 (L6.00) -10 MHz Ire, ul 871(N600) -15 MHz 46041 N2I(D4r'kI *IQ I AHLOA 700+600 Too AHF11 AWS+PCS FDD - midband 64/866 �L2100)-20 MHz 866 (N2100) -20MHZ B2 (L1900) - 20 MHz 825 (L1900) - 20 MHz BZ5 (N190Q) - 20MHz TDD - Band 41 N41(2.5GHz)-100MHz +80MHz 6rour+d E _ 0u Refer to voltage boager table far blaost 40►id1"* requirements oer radio type and trunk — longrh Ci Alf rr_:. SRAM LTE LTE FDDITDD A Irscalel RF PLUMBING DIAGRAM SCALE:NONE 1 ra p a y � n E O.i i ■ 0 w a Ln n w CL a �,ll�llll,r. Q�{� JEFF S. '%'L ITOWSKY :* = •''r5,'���11�r►4 �i4�• E%PIRES' 0713112G SIGNED: 01127r25 REVISIONS REV ISSUED FOR DATE BY A FOR CLIENT REVIEW 12116R4 RAK 0 FINAL 01r27125 TRK ,-�22 f z w r o Z w 7 0 F g / Z Q Z CHECK JKR a U U .y H DRAWN:RAK o V JOB: T2400737 w � J / / w C, J_ ~ Z 01 U /m� A-5 5 j U O U a ¢ EQUIPMENT DETAILS 22.6^ CD m FRONT B.3" BRACKET OPTIONS I I OPTION A - FMAB F'SF-E ` FrGrA�,� ' � lifi ®ice© MW -MW �>1A COMMSCOPE FFW-65C-R2N23 n¢"' OPTION B - FSAO SIZE (L x W x D): 96.0" x 22.8" x 8.3" ,i. FPIA 0kr FSAP WEIGHT (W/O MOUNTING KIT): 103.6 LBS I _ I IVI7ICIA ANTENNA DETAIL F FSEE DETAIL SIDE SCALE: ,I NONE 'N�. SCALE: NONE FP)<A MOUNTING BRACKET f'MM120 BOLT M I0020x105mm BOLT FMFA FIXING POINTS FPKA MOUNTING BRACKET DETAIL SCALE~; NONE 91 AHFII AirScale RRH 4T4R B25/66 480W Technical data Standard 3GPP compliant Supported RAT" 2G, 3G, 4G, 5G or combination i.e. 4G/5G, IoT (SA,158,I13), FDD Band / Frequency range Band 25: RX 1850 MHz - 1915 MHz, TX 1930 MHz - 1995 MHz Band 66. RX 1710 MHz - 1780 MHz, TX 2110 MHz - 2200 MHz Max. supported modulation' 256QAM UL / 1024 QAM DL Number of TX/RX paths' Instantaneous bandwidth (IBW)' Occupied bandwidth (OBW)' Max. RF output power' Dimensions (HxW■D) volume Weight (excluding mounting bracket) Supply voltage / Connector type Antenna ports Optical ports' Other interfaces / Connector type Operational temperature range Cooling Installation options Ingress / Surge protection 4T4R Full band Full band, OBW 1325 65MHz (UL/DLI, B66 7OMHz (UL) 90MHz (DL) 4x8DW in any band while 4x40W in other band 641 x 342 x 115 mm Icore), 676 x 369 x 145 mm (envelope)" 25 L 32 kg" DC -40 5 V ... -60 V / Nokia 2 pole connector 4 x 4.3-10 3 x SF28 Ports CPRI 9.8 Gbps (Rate 7) RET RS485, AISG 3.0, EAC MDR26 -40 °C +55 °C Forced Convection (fans) Pole, wall, rail IP65, DC Power Port: 20 kA 8120 Ns 25.2"7Q5Ib 13.5"x4.5" AHFII DETAIL '=7Q51bs SCALE:NONE 2 4 EM001111111 0 a 3 x c� = to m Fw v aaLr) u) a) � w C4 U� C4 3 M O m M -� a ,%I IIII II,, JEFF S. s 'L ITOWSKY 5Q�-ot]B rar�s/ON✓fl "'.1% EXPIRES 1I773112e SIGNED- 01127T REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 12116124 RAK 0 FINAL 01127125 TRK wc�Zag LU Qz w 0 tr � L) a `� I- � a (n Z a Z g p OF J Z d U U `J z ro In U 2 W O to OJ}U} W W F a LU w v F- Z m i -mU)i 7 J 7 U as —icn< 'CHf:CK JKR nRAVM RAW Jub: 124uu/3/ A-6 EQUIPMENT DETAILS Nokia AirScale System Module Indoor consists of the following items: Weight Empty: 5.1 kg (11.2 Ib) ■ One Nokia AirScale Subrack (AMIA), including backplane for high bandwidth connectivity between processing plug-in units With dummy panels: 6.6 kg ■ One or two Nokia AirScale Common (ASIA) plug-in units for transport interfacing and for (15 lb) centralized processing With all units: 23.9 kg (52.7 lb) ■ Up to six Nokia AirScale Capacity (ARIA) plug-in units for baseband processing and for optical interfaces with radio units The AirScale Subrack (AMIA) has a 3U height and fits into a standard 19 in. rack. Multiple subracks can be stacked on top of each other, The indoor subrack includes fans, a backplane for internal communication, and the DC -feed. The direction of the cooling air can be changed by rotating fans. The default direction is front -to -back. + 4P �'� rifian l7,fin1 - �� ,225m 100�) DETAIL C-C L6" x 8" x 1/2" x 0'-4 1/2" LONG (2) 518" DIA. BOLTS ASTM A325 N.S. & NF.S 6" 18„ 18„ ao (2) 5/8" DIA. BOLTS ASTM A325 N.S. & NF.S. AirScale Capacity ARIA AirScale Subrack AMIA AMIA DETAIL SCALE; NONE DETAIL B-B (2)5/8" DIA. BOLTS^ r SEE DETAIL A -A ____7_ AirScale Common ASIA MrrAll A A (2) 5/8" DIA. BOLTS' r n B 8 L6" x 8" x 1/2" x 0'-4 1/2" LONG L4" x 4" x 1 /4" x 4'-6" LONG (CUT TO FIT) -SEE NOTES f (2) 5/8" DIA. BOLTS ASTM A325 N.S. & NF.S. WIDE FLANGE t 1 'X' S!) 1 B-3/4" l PERFECT VISION ( PART # PV-E Q-STEP 1) j I WEIGHT: 58lbs NOTES: • MAXIMUM SPAN OF L4" x 4" x 1/4 IS 4'-6" MAXIMUM CABINET WEIGHT IS 3000lbs MINIMUM (2) L4" X 4" X 1/4 SUPPORTS PER CABINET 1 BEAM TO ANGLE CONNECTION 3 SCALE:NONE NOTE: SPACE EACH KIT 5'-0" O.C. LENGTH OF RUN PIPE/CONDUIT CLAMP ALL PART # ARE "UNISTRUT" CONDUIT SIZE PART # 1" P2030 1-1/2" P2034 2" P2038 2-1/2" P2043 3" P2046 4" P1120 ALL THREA ROD (TYP.) PIPE CLAMI NEW COND PIPES MAY ABOVE OR UNISTRUT 1-STEP KIT DETAIL SCALE: NONE CONDUIT TRAPEZE DETAIL SCALE:NONE I, 1000 UNISTRUT 4 o ■ 0 a 2 C0 (0W W 03 a a LO V- w r �m0� Z to a ,I t111117� I oJEFF S. ���� + TOWSf(Y 1* _ EXPIRES:07/31/26 SIGNED:01127/25 REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 12/16/24 RAK 0 FINAL 01/27/25 TRK t- J c7 w U Z Z W H W ce =)� w F- M g O N Z Z _O i p Q J Z a v 3 Z F M w O to 0 U W U w 0 W J J i w U ~ ? m r i m N 7 J 7 U Q U o' Q DRAWN: RAK A-7 EQUIPMENT DETAILS HUBERI+SUHNER F9l e box 19" 1 U trunk enclosure 24 x LC D Singlemode UPC/APC and Multimode OM4 � FIBER TRAY DETAIL SGALE:NONE NOTE: MANUFACTURER AND PART # OF NEW VOLTAGE BOOSTER TO BE VERIFIED. Upconverter Unit PDU • HCS 6x24: 6 x 40At Breaker Configs Supported 0 HCS 2.0: 3 x 80A*t • HCS 1.0: 1 x 200A* VOLTAGE BOOSTER DETAIL SCALE:NONE 1 3 FLOOR MOUNT RACK MOUNT SPD TRAY DETAIL SCALE: NONE A EXPANSION PLATE (AS -NEEDED) USE THIS USE THIS SECTION SECTION UNDER UNDER PAVEMENT GRASS OR VEHICLE OR LAWN TRAFFIC AREA AREA RESTORE SURFACE TO ORIGINAL CONDITION /` / 6" WIDE UTILITY WARNING TAPE (6" TO 72" BELOW IRE LENGTH i \ / - % /�%x F OTRENCH RETURN ORIGINAL MATERIAL ❑ . . TO TRENCH, COMPACT TO z /�/Z 95% STANDARD PROCTOR GRADE 9/CA-6 GRAVEL N r � COMPACTED TO 95% STANDARD PROCTOR J % r\\ FOR NEW ELECTRICAL, TELEPHONE OR FIBER SERVICES - SEE UTILITY AND SITE PLANS. PROVIDE l ��� \ ` APPROVED PULL BOXES -„;•.,`. ;z - AS REQUIRED AND ti +• COORDINATE INSTALLATION WITH ALL UTILITY COMPANIES FOR 12" INTERFACING AT SAND TERMINATION POINTS. PROVIDE FULL LENGTH PULL ROPES (TYR) UTILITY TRENCH DETAIL SCALE: NONE 21 v�" s 0 0 _M W a a a� fn W U O COM a 0 l+►rr 1 r JEFF S. ` 2 ITOWSf('r� = rrrss� EXPI !ES:07/31/26 SIGNED:01/27/25 REVISIONS REV, ISSUED FOR DATE BY A FOR CLIENT REVIEW 12/16/24 RAK 4 FINAL 01/27/25 TRK w UO ¢ Z K M z w 0 2 > U Z W 7 En F � ❑ rn � � z a z 3 0 O i 0 Q Q Z a U U F-i z z ❑ N U z en O U w U w ❑ w w J . w U ~ ? m 4 -mU) mw � � 0 U Cy2t U Q 0 o Q 'CHECK: JKR JOB: T2400737 A-8 EQUIPMENT DETAILS Retrofit HPL3.05 —Cabinet Layout For sites with an existing HPI.3 cabinet, equipment will need to be added to the HPL3 to support the HCS 6x24 trunk — This "retrofit" equipment is highlighted in Yollow below: • Voltage booster • SPDTrays • FiberTray w/Patch Panel Sites with an existing HPL2 or older cabinets must upgradeto the HPL3.1 or HPL3,05 cabinet (see slides further ahead) - The older cabinets to ck the rack space needed to accommodate a ddlns a booster, 5p0 tray, and fiber trays Delta HPL3.05 Power System Dm to vakA& a a4rct of 41 I'F nvrAerli .� Nokia AMIA FSMFandFSEEwIII Nokia need to be I(;SIM Baceband] reloeatedupwirds _ from bottom of Rack -Mounted SPD Tray er.oww.iw r•.= Nokia FSEE (Alarm-�---�� Interface) In FMAS Rack_ I . Flvor•Mounted T•MubIleCanfldenIi SPI Nokia 7250 IKR-e (CSR) Retrofit HPL3.05 - Hole Punch in Delta HPL3 for HCS 6x24 Trunk Entry The Delta HPI3 will require HCS 6x24 trunk a12.5-holes entry holes to be punched at the locations I RU Equlpmtrn w![h 6.5' depth marked In the diagram to the right Only punch holes as -needed for the number of trunks being installed, starting with the hole shown towards the rear of the cabinet as T I the first hole ;I _ -_ eN I NOTE: INSTALL NEW 3" L.B. AT KNOCKOUT PER EACH HCS 6x24 TRUNK REQUIRED. Rear ' 1i�21��3 DW 0M16At are in i �nrn ' eu{n* 0 I _7 1 � NLLEYapy a+rs•rnsr�rr.�r. From HCS 6x24 TRUNK ENTRY DETAIL 2 SCALE:NONE HPL3.05 SITE SUPPORT CABINET SCALE: NONE NOT USED SCALE: NONE 3 >n � Ill s" irk V T g �W O C: 0 Q 2 C9 = (D H v LO co w �w �3�M � r O m Cl) cn Z o9 Q •'`G 01�1�' , r, ?f JEFF G.•- r TOWSI(Y � 509 K6 '�•�fQfVAIL. �O N 1111�� EXPIRES: 07/31126 SIGNET] IM27125 REVISIONS REV. ISSUED FOR DATE BY A FORCLIENTREVIEW 12/1624 RAK 0 FINAL 012725 TRK rz ¢ � w U Z W Z � ~ w � � ��orn � / z g ' z �o/ pF- Z 0 Q GNED7C JKR U U ,p = R � r DRAWN: RAK 0 O U JOB: T2400737 w 0 W / J_ ~ Z m U �/mcn A-9 C, ¢ U a ¢ EQUIPMENT DETAILS e MMA Smarter. Greenei. Together. Specifications Model SB3 (Small Battery 3 Cabinet) Construction Aluminium enclosure Dimensions 15 x 72 x 35 in. (381 x 1829x 889mm), (W x H x D) Depth with Door: 37.4 in. (950mm) Weight —310 Ibs (-141kg) (without batteries) Internal rack dimension 4 battery trays to support up to 2 strings 210Ah batteries Mounting options Pad -mount, plinth option Finish Polyester Power Paint (Tan) Safety UL Listed , IEC / EN 60950 2. Environment Operating temperature -40°C to +50"C (-40"F to +122"F) with solar load Protection class IP55 designed to GR-487 Acoustics 65dBA Humidit relative} 13. 95%, non -condensing (Max.) Thermal Management Cooling Equipment: Direct Air Cooling HeatinLl Equipment: ,4. Forced air heatirt(1 1000W AC heaters Equipment Knock -out plate on each upper side wall Cable entry Additional knockouts each side Door latch 3 point latching, 5116 nut driver tool, pad -locking capability Primary ground 10 double-hole''%'-20 threaded holes on 5/8" center ground bar Lifting Ears 4 Lifting Tabs Plinth Optional 6" plinth available AC Load Center: 30A heater breaker Left or Right side AC entry options AC Surge Protection (option) DC Load Center: 600A bulk feed bus bar (2) 400A bolt in battery breakers (4) 2-hole lug landings,(2 output/2 input from second battery cabinet) Temp Probes Standard equipment 4/0 cables from breakers and return bar to each string. Battery Trays: (4) battery trays (two trays required per -48V battery string) Hold up to two (2) -48V battery strings (210Ah max each) Connection kit: (1) DC 10A Breaker supplied (install onto HPL3 Power Cabinet) (2) 4/0 tray to tray cables supplied (4) High current Cell -Cell straps supplied (16) High current front terminal adapters supplied LED interior cabinet light (2) DC powered Axial fans with (1) F5 Filters Front Door: Door intrusion alarm 1I 1000W AC Qgoiad beaters Ordering5. Cabinet ESOF015-ECV03 Small Battery 3 (SB3) Cabinet Plinth, 6" 3798D000000120-S Plinth for SB3 'All specifications are subject to change without prior notice. r< — M SB3 BATTERY CABINET SCALE: NONE �o s OCR Era= s • Irk � � a � g 0 r ■ 0 Y x C� W ro m Fw v aa Lo LL co EL n LL �30 M GQ CO Z Q � `1111111��r bra 0 .....!V JEFF S. 'L ITOWSKY I fH)S i1��w= ~' ^ �6, % rr�4��10N'1 EXPIRES- 07131126 SlGNEO. 0112705 REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 1211624 RAK 0 FINAL 012725 TRK CHECK: JKR DRAWN: RAK JOB: T2400737 A-10 EQUIPMENT DETAILS z Power Protection Cabinet (PPC) 225A with Generator Input and AC Alarm A Product Features • Single wall Aluminum enclosure • Powder coated finish • Pad lockable 3-point door latch • Type 3R & IP55 rated • Metal oxide varistor surge protection • Camlok generator connection • Main AC Input Detection Alarm www.deltaww,coin A&ELTA Snru rc�. Ca �;rn rr 1og•_Un:r Specifications Model / Part Number 4910163600 Delta Group Website: Construction Single layer Aluminum enclosure, Type 3R wvw dellaww com Dimensions (W x H x D) 20 2 x 39 x 11.2 inch excludes generator connections Product Website: 29.7 x 39 x 11.2 inch including RH Camlok generator box v"rw dellapo*Prsulutions rom Weight 71 Ibs (without packaging) Finish Polyester Powder Paint United States of America & Canada: Door Latch 3-Point latching, pad lockable Della Electronics (USA) Inc. UL50 (Cabinet) 2925 E Plano Parkway Safely UL891 Dead Front Switchboard Listed Plano. TX (Texas) 75074 Suitable for Use as Service Equipment (N-G Bonding kit included) Sales and Orders: 2 Environment DEUSTPS-Sales@deltaww.com Operating temperature -40'C to +46 C (-40'F to 1151) DEUSTPS Orders@dellaww.com Humidity (relative) 95 % , non -condensing (Max) Protection class Tue 313 Field Support: 3. AC Section 1-877-DELTA-08 option 3 Voltage 240/120 Single Phase (3 wire + Ground) (87 7-335-8208 option 3) Current 225A AIC Rating Utility 65,000 Amps DEUSTPS Snppuil Cdeltavm, com Generator Interface: Camlok Connections (Right Mount) Installation Services: Service Disconnect: Square D 225 Amp (65kAIC) Mechanical DEI ISTPS SeF vices{adeila�-v.com Slide Bar Interlock Load Center: Square D 225 Amp, QO Series, 24 Position RMA: Other features Surge Protection Device (SPD) - 1 ea. AC20BOM-02 DEUSTPS RMA aaellaww cx , Square D 30 Amp, 2-Pole Breaker for SPD Ground Bar Silkscreen Dead -Front Lift Off Style Captive Dead -Front Fasteners Loss of AC Input Alarm PPC 4910163600 Power Pedestal Cabinet - 225A wl AC Alarm AC Alarm Relay Kit FRU 5630102506 Alarm Monitoring Retrofit Kit for PPC GENERATORINPUT •Male Receptacle Tnbt Luck Panel Mourn connectors (nor included) 'All specifications are subject to change without prior notice. EN z23n2P17/ FH PPC DETAIL SCALE:NONE 1 �s Q� O LL �E <2p s (w' E O ■ } 2 CO _ (o M a Lu CD W h - W CL CO m g O m m Z N a ��tltltllrr . GO At i JEFF S, ITOWSICY w wan gas-aoa 4* • J " 41p ,pill EXPIRES: 07131128 SIGNED: D1127I25 REVISIONS REV ISSUED FOR DATE BY A FORCLIENTREVIEW 12116124 RAK 0 FINAL 01127/25 TRK F- J LD J w U Z i Z Wlu F 7 W N F- Z / z a z g moo/ O Q J Z a V LPi Z 07 F U Z U Z 75OwU W L) W } ❑ W / F J J / W L) ~ Z m / m U, O ? j U ¢ U a ¢ DRAWN: RAK JOB: T2400737 A-11 EQUIPMENT DETAILS LEGEND F — FIBER LINE E ELECTRIC LINE A — ALARM CABLE VOLTAGE DROP (FOR 200A, 120/240V, 1 PH) FROM NEW PPC TO EXISTING METER LENGTH WIRE SIZE VOLTAGE PERCENTAGE OF RUN DROP (VOLTS) OF VOLTAGE (1) RUN OF t65'4' (3) 3/0 AWG & 2.21 V 0.92% (1) #6 GND (1) NEW 2" RIGID AC CONDUIT NTH (4) #4/0 AWG AND (3) #12 AWG FOR POWER FROM NEW BATTERY CABINET TO NEW SITE SUPPORT CABINET (1) NEW 2" RIGID CONDUIT FOR DC & ALARM FROM NEW BATTERY CABINET TO NEW SITE SUPPORT CABINET NEW HPL3.05 SITE SUPPORT CABINET TO BE INSTALLED. SEE A-9: • NEW CSR IXRe V2 • NEW FSEE --� NEW BATTERY CABINET TO BE INSTALLED. SEE A-10 — E E NEW TOPAZ ILL CONDUIT BODY (PART # LL7MHDG) W/ WATERTIGHT MYERS HUB. UTILIZE FORWARD MOST 2" KNOCKOUT FOR TECH ACCESS AT CABINET (TYP.) (1) NEW 2" RIGID CONDUIT WITH (2) #3/0 —1 ¢ AWG BLACK/RED WIRES FOR POWER, (1) 1�(v)�� #3/0 AWG GREEN WIRE FOR GROUND & (1) #4 AWG WHITE WIRE FOR NEUTRAL _ TO RUN FROM NEW SITE SUPPORT jEjff4 E A E A CABINET TO PPC. CONDUIT TO BE INSTALLED WITH PULL STRINGS NEW 1" RIGID CONDUIT FROM EXISTING FIBER ENCLOSURE TO NEW SITE SUPPORT CABINET FOR DC POWER — NEW 1" RIGID CONDUIT FROM EXISTING FIBER ENCLOSURE TO NEW SITE SUPPORT CABINET FOR FIBER -- UTILITY SCHEDULE FROM TO WIRE OTY. & TYPE GROUND CONDUIT FUNCTION SIZE PPC SSC (2) 3/0 (1) #4 NEUTRAL WIRE (1) 3/0 FOR GROUND 2" RMC ELECTRIC CONDUIT PPC SSC (1) PAIR OF #18 AWG N/A 1" RMC ALARM CONDUIT FIBER SSC 20' SM FIBER N/A 1" RMC FIBER CONDUIT ENCL. SSC FIBER (2) #12 AWG (1) #12 AWG 1" RMC ELECTRIC CONDUIT ENCL. BATTERY SSC (2) CAT-5 CABLES N/A 3" RMC TELCO CONDUIT CABINET BATTERY (2) PAIRS OF 410 TELCO FLEX SSC CABINET POWER CABLES &(3)#12 AWG N/A 2" RMC ELECTRIC CONDUIT BATTERY SSC TBD N/A 2" RMC ELECTRIC+ CABINET ALARM CONDUIT PPC NOTES: LOW VOLTAGE CONDUIT FROM PPC TO SSC (2) RUNS OF BELDEN 27916A 18 AWG 2 CONDUCTOR TYPE TC CABLE, 600V WIRE • WIRE TO NORMALLY CLOSED RELAY FOR LOCP WIRE TO NORMALLY OPEN RELAY FOR GENERATOR RUN (1) NEW 3" RIGID CONDUIT WITH (2) #12 AWG FOR BREAKER & ETHERNET CABLE FROM NEW BATTERY CABINET TO NEW SITE SUPPORT CABINET. BATTERY CABLE WITH ANDERSON CONNECTOR ROUTED INSIDE THE HPL3.05 CABINET THRU 3" CONDUIT WITH MYERS HUBS. LONGER CABLES MAY NEED TO BE MADE TO ACCOMMODATE THE 12" CAB SPACING NEW TOPAZ LL/LR CONDUIT BODY (PART # T.B.D.) W/ WATERTIGHT MYERS HUB AT SITE SUPPORT CABINET (TYP.) NEW TOPAZ LR CONDUIT BODY (PART # T.B.D.) W/ WATERTIGHT MYERS HUB AT SITE SUPPORT CABINET (TYP.) NEW HD LED SAFETY LIGHT WITH TIMER TO BE INSTALLED (TYP. OF 2). SEE 2&3/E-2 EXISTING CONDUIT TO BE UTILIZED FROM NEW PPC TO EXISTING METER. FINAL ROUTE AND CONNECTION TO BE VERIFIED IN 1 FIELD PRIOR TO CONSTRUCTION NOTE: EXISTING CONDUIT TO BE UTILIZED FROM E NEW PPG TO EXISTING METER. FINAL ROUTE AND CONNECTION TO BE VERIFIED IN FIELD PRIOR TO CONSTRUCTION. "--INSTALL NEW 200A, 4 POLE - BREAKER FOR NEW SSC - NEW 1" RIGID CONDUIT NEW 225A PPC TO BE EXISTING FIBER FROM NEW PPC TO INSTALLED. SEE A-11 ENCLOSURE NEW FSEEFOR LOSS OF COMMERCIAL ; i ING FYGA L� POWER ALARM GPS ANTENNA NEW GPS CABLE FROM ANTENNA TO NEW SITE SUPPORT CABINET ACTUALLENGTH ACTUAL FACTORY LENGTH +10% SAFETY LENGTH FACTOR GPS ANTENNA CABLE LENGTH t10'-0" t1 V-0" (30m ) (30m UTILITY PLAN SCALE: 1/2" = V-0" 1 a � � 0.9 y LL s � E 0 r ■ 0 n } 2 2 co Lnco F M CD co W `- 111 CL O m M Z to Q t JEFF S.'L TOWSKY * _ -006 _ 1ti ��i111►►► EXPIRES: 07/31/26 SIGNED: Di127125 REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 12/16/24 RAK 0 FINAL 01/2725 TRK W U Z W z w F- U W V) F � / z g ' qw z _o/ UO F- J Z C:rEL�K: JKR a Z U z ] , U DRAWN: RAK N mO LU UO JOB: T2400737 w O w / J F Z m U P/m� E-1 � J 2 U S o J U ¢ U a ¢ UTILITY PLAN SITE NUMBER: T-Mobile MODEL NUMBER: 4910163600 VOLTAGE: 24OV/120 PHASE: 1 VVIRE: 3 MAIN BREAKER: 200 AMP BUSS RATING: 225 AMPS AIC: 65,000 MOUNT: SURFACE NEUTRAL BAR: YES GROUND BAR: YES ENCLOSURE TYPE: NEMA 3R N to GROUND BOND: YES PANEL STATUS: NEW INTERNAL TVSS: YES CKT LOAD DESCRIPTION BREAKER AMPS BREAKER POLES BREAKER STATUS SERVICE LOAD VA USAGE FACTOR PHASE A V, PHASES VA USAGE FACTOR SERVICE LOAD VA BREAKER STATUS BREAKER POLES BREAKER AMPS (LOAD DESCRIPTION CKT 1 SURGE ARRESTOR 60 2 ON 0 1.00 9525 1.25 9525 ON 2 150 :SITE SUPPORT CABINET 2 3 0 1.00 9525 1.25 9525 4 5 SERVICE LIGHT (IF INSTALLED) 15 1 ON 30 1.00 9555 0.00 0 N/A — --- -- 6 7 — -- -- N/A 0 0.00 0 0.00 0 N/A -- — -- 8 9 — -- -- N/A 0 0 0 0.00 0 N/A -- — 10 11 — -- -- NIA 0 0 0 0.00 0 N/A -- --- -- 12 13 — -- -- N/A 0 0 FO 0 0.00 0 NIA -- -- 14 15 — -- -- N/A 0 0 0 0.00 0 NIA -- — — 16 17 — -- -- N/A 0 0 0 0.00 0 NIA — -- 18 19 — — -- N/A 0 0.00 0 0.00 0 NIA — -- -- 20 21 — -- -- N/A 0 0.00 0 0.00 0 N/A -- — -- 22 23 -- -- N/A 0 0.00 0 1.00 180 ON 1 20 GFI 24 19080 9525 VA I TOTAL KVA 28.61 AMPS 119.19 FF Series Colttmwelal Series The FF Was Commemal Auto OII Timers en deel9ned to repece any standard wllk 9W • staple tr A kiy�q. THa eerkle of (j F eM19y-eflIM111 n+e;>MYtw� lyne4 dGn'Xp retlYe ebMzla:y to Terc owtia, In 6d0bn. my wlMtetIC61N 11mn 1M ON Imes for hn7, • Pall 7 t 7/' IghWq, enbe neatens, and o"W soapy eonsrnrg loam - 10 FOMum • HOd 100,xe arablse the year to arerdde the aulomedc 50 r ow -off luncdon • Rip2nd f,eq alb pinte am y wtVralalm IM abuse mcmntered In �r �20 LlefMla�e ertik ar rrbk //]}6•�A • ii011ewow "6NMad m6f6F Ilp"Ia ca"tri1Gtlon) lock me" �O / / i 1 l � - NFG requkarrrM ]tl • TVm saving Lip twi WmkW connW§On wkh leete-type %minals • Press -on Woo drlpn ensures quick and eIty IfNUMeaw • CR. compatible IVaI A]f W Yl11.•.�.gl{ YMYµ Y ✓L1aCr eM1I.M tl:wA. r?r,.—...,� � •. .rrrrr,l�r,rp Retllnps Rest. 70 AMP, 126 VAC, SOI60 Hz 10 Amp, 250 VAC, S0100 Hz 10 Amp, 2T7 VAC. 50100 Hz NOTE: TVgsle; .1Amp.125VAC CONTRACTOR TO INSTALL I HP 120 VAC 5CM Hz NEW INTERMATIC AUTO 2 HP 240 VAC MM Hz SHUTOFF 1HR TIMER, OR APPROVED EQUAL. D.na nsow" P 79• H a l 61 W i 1.19" D 20 AMP LIGHT SWITCH/TIMER 2 SCALE: NONE PANEL SCHEDULE SCALE: NONE drjr,amn} "215mm) ` 461'(f 17m 2.36"(60mm) • ) 376-(915mm) FLS15U50B MANUFACTURER: MAXLITE MANUFACTURER PART NO: FLSISUSOB - MAX OPERATING VOLTAGE: 120-277 UNIVERSAL VOLTAGE LED FOR HID REPLACEMENT: 10OW HID TECHNOLOGY: LED APPLICATION: OUTDOOR FIXTURE TYPE: FLOOD WATTS: 15W LUMENS: 1,260 COLOR TEMP: SOOOK COLOR RENDERING INDEX: 70 BENEFIT: DLC QPL LISTED, WET LOCATION RATED COMMON NAME OF COLOR TEMPERATURE: DAYLIGHT DIMMABLE: NO FINISH COLOR: BRONZE FIXTURE MOUNTTYPE: TRUNNION MOUNT NEW EXTERIOR LIGHT TIMER AND GFCI SPECIFICATION: (1) SIGMA TWO GANG CLEAR COVER, EXTRA DUTY WITH LOCKABLE ENCLOSURE. (1) INTERMATIC 60 MINUTE MECHANICAL TIMER, FF60MC (1) CASTALUMINUM, 2 GANG WEATHERPROOF FS BOX, NO LUGS, DEEP BOX. APPLETON FS-2-75A OR HUBBELL-KILLARK 2FS-1. USE BACK OF GANG BOX FOR ENTRY INTO PPC, SEAL FLUSH AGAINST PPC WITH GASKETING MATERIAL, AND/OR SEAL EXTERIOR PERIMETER WITH SILICONE BEAD TO PREVENT WATER INTRUSION. • (1) GFCI 15 AMP LEVITON MT759-T, 2-POLE, 3-WIRE, 15 AMP, 125 VOLT, 5-15R NEMA, WALL BOX MOUNT, LIGHT ALMOND, HEAVY DUTY, COMMERCIAL GRADE. \\NOTE: NO RESIDENTIAL GRADE GFCI ALLOWED.// • (2) OUTDOOR FLOOD LIGHTS, RATED INITIAL LUMENS>1,260 EACH FLOOD. HTTP://1WW W.MAXLITE.COM/PROOUCT5/SMALL• Fi00D•LIGHT5/FLS35USoo OR EQUIVALENT MAXLITE MODEL FLS15U50B/N, @ 1,235 LUMENS. ➢ TYPICAL INSTALLATION, REGARDLESS OF PPC STYLE OR TYPE OR EXISTING OUTLETS, ➢ LIGHT TIMER ON 15A CIRCUIT, LIGHT CONTROLLED BY COUNTDOWN TIMER GFCI ON SEPARATE 15A CIRCUIT. ➢ IF PPC HAS EXISTING INTERIOR MOUNTED GFCI, IT TOO SHALL BE WIRED FOR SERVICE. ➢ EQUIVALENT MEETING SERVICE REQUIREMENTS, OR BETTER, EQUIPMENT MAY BE SUBSTITUTED AND INSTALLED WITH PRIOR T-MOBILE PM OR CM LED LIGHT DETAIL SCALE: NONE 3 a a w u � 3 ® a s q Q� Od yo JP-4 CD �p a O 3w. ■ ■ 0 r a x LU m � vS7 S w i ■/'D = D Yl�iyl 3r a� O m M Z N a Sllllllir7 JEFF S. TOW4{Y s� = 549�QO6 �r�►1111 l�t� EXPIRES. 0713V26 SIGNED- 01127125 REVISIONS REV. ISSUED FOR DATE BY A FORCUENTREVIEW 12116124 RAK 0 FINAL 01/27/25 TRK w a Z 4a z w U W to r qa z / O / UO Q Z CHECK- JKR d V U � oar j N DRAWN: RAK Z i U Z 0 ui OU JOB: T2400737 w w a Lu / W J ~ m U ? </mw- E-2 7 J 7 U ? O - U a U a a ELECTRICAL DETAILS WATGC. 1 ALL ELECTRICAL WORK SHALL CONFORM TO THE LOCAL ELECTRICAL CODE (EDITION ADOPTED BY LOCAL JURISDICTION) AND APPLICABLE LOCAL CODES. 2 GROUNDING SHALL COMPLY WITH THE LOCAL ELECTRICAL CODE. 3. ALL ELECTRICAL ITEMS SHALL BE U.L. APPROVED OR LISTED, 4 WIRES AND CABLES FOR POWER AND LIGHTING SHALL BE COPPER WITH TYPE XHHW, THWN, OR THHN INSULATION- SOLID CONDUCTORS FOR #10 AWG AND SMALLER, STRANDED FOR LARGER THAN #10 AWG. MINIMUM SIZE #12 AWG. 5 WIRES AND CABLES FOR POWER SHALL BE INSTALLED IN GALVANIZED RIGID STEEL CONDUIT OR FLEXIBLE LIQUID TIGHT CONDUIT AS INDICATED ON DRAWING. 6, CONTRACTOR TO OBTAIN ALL PERMITS, PAY PERMIT FEES, AND BE RESPONSIBLE FOR SCHEDULING INSPECTIONS. 7. COORDINATE WITH UTILITY COMPANIES SERVICE ENTRANCE REQUIREMENTS. B PROVIDE ALL LABOR AND MATERIAL DESCRIBED ON THIS DRAWING, AND ALL ITEMS INCIDENTAL TO COMPLETING AND PRESENTING THIS PROJECT AS FULLY OPERATIONAL. 9 GROUNDING CONNECTIONS SHALL BE EXOTHERMIC TYPE TO ANTENNA MASTS, AND THE GROUND BARS REMAINING GROUNDING CONNECTIONS SHALL BE COMPRESSION FITTINGS. 10. GROUND COAXIAL CABLE SHIELDS AT BOTH ENDS WITH COAX CABLE GROUNDING KITS & INSTALL WEATHER PROOFING KIT AT EACH CONNECTION- 11. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE, EXCEPT AS OTHERWISE INDICATED. GROUNDING LEADS SHOULD NEVER BE BENT AT RIGHT ANGLE, ALWAYS MAKE AT LEAST 12" RADIUS BENDS. #6 WIRE CAN BE BENT AT 6" RADIUS WHEN NECESSARY. 12. CONTRACTOR TO PROVIDE GROUND RING AS SHOWN ON GROUNDING SITE PLAN AND GROUNDING RISER DIAGRAM. CONTRACTOR SHALL TEST AND VERIFY THAT THE IMPEDANCE DOES NOT EXCEED 5 OHMS TO GROUND BY MEANS OF A BIDDLE-MEGGER TESTER. GROUNDING AND OTHER OPERATIONAL TESTING SHALL SHALL BE WITNESSED BY THE OWNER'S REPRESENTATIVE. 13. CONTRACTOR TO PROVIDE TELEPHONE CONDUIT AS SHOWN ON PLANS. 14 CONTRACTOR TO PROVIDE ELECTRIC CONDUIT AS SHOWN ON PLANS. 15. NOTIFY LOCAL UTILITY SERVICE PRIOR TO ANY INSTALLATION 16. ALL EQUIPMENT FURNISHED BY OTHERS SHALL BE PROVIDED WITH PROPER MOTOR STARTERS, DISCONNECTS, CONTROLS, ETC. BY THE ELECTRICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. THE ELECTRICAL CONTRACTOR SHALL INSTALL AND COMPLETELY WIRE ALL ASSOCIATED EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WIRE DIAGRAMS AND AS REQUIRED FOR A COMPLETE OPERATING INSTALLATION. ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF EQUIPMENT PRIOR TO ROUGH -IN OF CONDUIT AND WIRING TO AVOID CONFLICTS WHERE APPLICABLE. 17. GROUNDING CONDUCTORS SHALL BE COPPER OR SOLID TINNED COPPER. ALL CONNECTIONS MADE BELOW GRADE SHALL BE SOLID TINNED COPPER. ALL CONNECTIONS ABOVE GRADE STRANDED IS PERMITTED. BUS BARS TO BE TIN PLATED COPPER 16. ALL EXOTHERMIC WELDS ABOVE FINISHED GRADE SHALL BE PAINTED WITH CO -GALVANIZED ZINC ENRICHED PAINT TO MATCH COLOR OBJECT BONDED TO. 19. CONNECT COAX GROUND KITS TO MASTER GROUND BAR AT BASE OF TOWER. 20. CONNECT COAX GROUND KITS TO GROUND BUS AT TOP OF TOWER. 21. CONNECT LNA GROUND TO GROUND BUS AT TOP OF TOWER. 2Z ALL GROUNDING CONNECTIONS TO BE MADE USING EXOTHERMIC WELD PROCESS UNLESS OTHERWISE APPROVED BY DESIGNER. 23. ELECTRICAL CONTRACTOR TO PULL BONDING JUMPER AT CABINET ONLY IF DISCONNECT GROUND IS TIED TO GROUND FIELD INSTEAD OF SEPARATE GROUND ROD. 24. PLAN DRAWINGS SHOWN HEREIN DO NOT NECESSARILY DEPICT ELECTRICAL REQUIREMENTS OF INDIVIDUAL EQUIPMENT AND DEVICES SUCH AS THE EQUIPMENT GROUNDING REQUIREMENTS, POWER REQUIREMENTS AND TELCO RACEWAY REQUIREMENTS. 25. PLAN DRAWINGS SHOWN HEREIN ARE DIAGRAMMATIC AND DO NOT NECESSARILY DEPICT THE EXACT EQUIPMENT QUANTITIES, LOCATION, LAYOUT AND CONFIGURATION. REFER TO ARCHITECTURAL PLANS FOR EXACT EQUIPMENT LOCATION, LAYOUT AND CONFIGURATION. 26. REFER TO ARCHITECTURAL PLANS FOR THE LOCATION OF POWER AND TELCO POINT OF CONNECTIONS, THE DISTANCE OF THE RUN, AND THE SUGGESTED CONDUIT ROUTING. FIELD VERIFY EXISTING CONDITIONS SPECIFICALLY FOR CONDUIT ROUTING PRIOR TO BID. 27. NUMBER OF ANTENNAS REPRESENTED IN THIS DETAIL ARE FOR SHOWING CLARITY OF GROUND SYSTEM REQUIREMENTS ONLY. SEE RE INFO FOR ANTENNA QUANTITY. 28 CONTRACTOR TO'NOALOX' ALL CONNECTIONS TO GROUND BARS. 29. ALL GROUND WIRES ENTERING GROUND SHALL HAVE PVC SLEEVE. ANTENNA SECTOR #2 AWG SOLID TINNED GROUND WIRE FROM NEW ANTENNA MAST PIPE TO ANTENNA SECTOR GROUND BAR (AS NEEDED) (TYP ) 1 i #6 AWG STRANDED GREEN JACKETED I GROUND WIRE TO AHFII FROM ANTENNA SECTOR GROUND BAR EXISTING ANTENNA GROUND BAR AHFI] — pry I (TYP PER SECTOR) i GRADE GROUND RING SITE SUPPORT BATTERY CABINET CABINET PPC f f I 1 � f I 1 LEGEND — — -- NEW GROUNDING WIRE EXISTING GROUNDING WIRE EXOTHERMIC WELD io MECHANICAL CONNECTION EXISTING EQUIPMENT NEW ANTENNA EQUIPMENT NEW GROUND EQUIPMENT RELOCATED EQUIPMENT NOTES: • AMIATO CABINET GROUND BAR: #6 AWG STRANDED GREEN JACKETED GROUND WIRE • FSEE TO CABINET GROUND BAR: #6 AWG STRANDED GREEN JACKETED GROUND WIRE • CABINETS TO GROUND RING: #2 SOLID TINNED COPPER GROUND WIRE IN 1/2" NON METALLIC SEALTIGHT WITH NO-OX, AND CAULKED • CABINET GROUND BAR TO GROUND RING: #2 AWG SOLID TINNED COPPER GROUND WIRE IN 1/2" NON-METALLIC SEALTIGHT WITH NO-OX AND CAULKED • PPC TO GROUND RING: #2 AWG SOLID TINNED COPPER GROUND WIRE IN 1/2" NON-METALLIC SEALTIGHT WITH NO-OX AND CAULKED GROUNDING RISER SCALE: NONE -5 NOTE: CONTRACTOR TO VERIFY FINAL GROUNDING SYSTEM RESISTANCE TO BE UNDER 5 OHMS. 1 ® a.a gp � O/�/$ yLL$ L,%^S E L 3 V � a � EP � w V r■, I 0 n } 2 C0 2 ro 01 Hon � co W 3 � a O m c Z N a it of, o., ` JEFF S. '��• ITOWSK'f* _ 509.6¢6--r r EXPIRES 07/31/26 SIGNED: 01/27/25 REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 12116/24 RAK 0 FINAL 01/27/25 TRK Z J () J U_ Z} KQ W Z W 0 w U N Q ~ z Z g ' q� z o. p ¢�a J Z U U CHECK. JKR EL os j F- N F- DRAWN: RAK o w 0 w JOB: T2400737 oU w � J J U ~ Z m 'mw GRA J U 0- KEY NOTES: 1/4" THK ELECTRICAL TINNED GROUND BAR 1. HARGER OR APPROVED EQUAL HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION 2. INSULATORS (UNLESS NOTED OTHERWISE) 3 318" STAINLESS STEEL LOCKWASHERS 4. WALL MOUNTING BRACKET 5. 3/8" STAINLESS STEEL BNLF BOLTS EXOTHERMICALLY WELD #2 AWG BARE TINNED SOLID COPPER CONDUCTOR TO GROUND BAR, ROUTE CONDUCTOR TO BURIED 8 GROUND RING AND PROVIDE PARALLEL EXOTHERMIC WELD CONTRACTOR SHALL USE PERMANENT MARKER TO 7. DRAW THE LINES BETWEEN EACH SECTION AND LABEL EACH SECTION ("P", "A", "N", "I") WITH 1" HIGH LETTERS v 5 4 USE THEFT PROOF FASTENERS ON 7 ALL GROUND BARS 0 0 COMMSCOPE �j 7 p 0 PART# 0 0 p p N I MTC9874KEY 0 pA 0 0 �0 / O 0 0 3 EXOTHERMIC WELD 2 6 #2 AWG SOLID TINNED TO GROUND EACH GROUND CONDUCTOR TERMINATING ON ANY GROUND BAR SHALL HAVE AN IDENTIFICATION TAG ATTACHED AT EACH END THAT WILL IDENTIFY ITS ORIGIN AND DESTINATION SECTION "P" - SURGE PRODUCERS SECTION "N" - NON -ISOLATED GROUND ZONE EQUIPMENT • MISCELLANEOUS NON -ISOLATED GROUND ZONE • COLLECTOR GROUND BAR EQUIPMENT • GENERATOR FRAMEWORK (IF AVAILABLE) • CABLE TRAY SYSTEM • TELCO GROUND BAR . EQUIPMENT FRAMES • COMMERCIAL POWER COMMON NEUTRAUGROUND . BATTERY RACKS BOND . DC POWER • FIBER GROUND BAR SECTION "I" - ISOLATED GROUND ZONE • EQUIPMENT ROOM COLLECTOR GROUND BAR . ISOLATED EQUIPMENT FRAMES • HVAC . ISOLATED GROUND BAR - IGB • RECTIFIER FRAMES SECTION "A" - SURGE ABSORBERS • INTERIOR GROUND RING • EXTERNAL EARTH GROUND FIELD (BURIED GROUND RING) • METALLIC COLD WATER PIPE (IF AVAILABLE) NOTES: -EXTERIOR GROUND BARS TO BE TIN PLATED -HARDWARE SHALL BE STAINLESS STEEL -CONTRACTOR SHALL GROUP INCOMING WIRES -CONTRACTOR TO APPLY'KOPR-SHIELD' TO ALL CONNECTIONS BUILDING STEEL (IF AVAILABLE) AC POWER GROUND BAR DETAIL ■ SCALE:NONE NOTE: THE FOLLOWING SYMBOLS SHOWN ARE HARGER ULTRAWELD EXOTHERMIC CONNECTIONS WITH PART NUMBERS BELOW. THESE CONNECTIONS MAY BE CROSS-REFERENCED WITH CADWELD CONNECTIONS WHICH ARE SHOWN IN PARENTHESIS. I.i GT GO HS HD (GR) (GT) (HS) (HA) `4 tn! VA LE VA BD, BE, BU (VH) (GL) (VS) (LJ) :Q!a cr.-� , BS XX PT RT (SS) (XA) (PT) (TA) EXOTHERMIC WELD TYPES SCALE:NONE 1 STAINLESS STEEL HARDWARE -- I I GROUNDING ) CABLE TAINLESS TEEL FLAT lASHER (TYP.) 3/8" X 1-1/4" STAINLESS STEEL HEX BOL TWO HOLE COP COMPRESSION t3Bnl INlll ml ELEVATION � SECTION "A -A" 1. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS 2. NO CRIMPING OF SOLID #2. USE EXOTHERMIC WELD ONLY STAINLESS STEEL 3/4" A3/8" O.D. FLAT WASHER (TYR) STAINLESS STEEL LOCKWASHER (TYR) STAINLESS STEEL NUTS (TYR) EXPOSED BARE COPPER TO BE KEPT TO ABSOLUTE MINIMUM, NO INSULATION ALLOWED WITHIN THE COMPRESSION TERMINAL (TYR) GROUNDING CABLE GROUND BAR CONNECTION DETAIL 2 SCALE: NONE TO ANTENNA 1 r� TO GROUNE TO PRIMARY CABINET HYBRID CABLE PROOFING KIT HYBRID CABLE GROUNDING KIT #2 AWG, STRANDED COPPER GROUNDING CONDUCTOR HYBRID CABLE GROUNDING HYBRID CABLE GROUNDING KIT 4 SCALE: NONE oo O■ E �//� appe LiS af6� � � E • r-� C� a s �w O ■ 0 r` } 2 0 _ co LU 00 00 n ~S S 1� S W 00 0 O m M Q N +1111111�� a JEFF S. '4 ITOWSKY# = 54� 405 � w1 �r SYOl+lAI fFti�+v IlllililTt�� EXPIRES 07131r26 SIGNED- 01l2: +rs REVISIONS REV. ISSUED FOR DATE BY A FOR CLIENT REVIEW 12/1624 RAK 0 FINAL 012725 TRK w U Z qi > L) wU w g Z w z O / O Q J Z Of L) U P Z Z f U Z rnOJU w o w / / w o O ~ Z m / m M O j U 0 O. 'CHECK!JKR JOB: T2400737 G R-2 GROUNDING DETAILS