Loading...
HomeMy WebLinkAbout022-738-14-3103-LUP-2024-587at&t Your World. Delivered. PROJECT SUMMARY TOWER OWNER: AMERICAN TOWER CORPORATION ADDRESS: 10 PRESIDENTIAL WAY WOBURN, MA 01801 CONTACT: TBA PHONE: (781) 926-4500 SITE ADDRESS: 10424W STATE HIGHWAY 27/70 RADISSON, WI 54867 CUSTOMER/APPLICANT: AT&T WIRELESS 95 W. ALGONQUIN ROAD ARLINGTON HEIGHTS, IL 60005 LATITUDE: 45° 46' 32.71" N ( 45.775753°) LONGITUDE: 91° 12' 34.60" W (-91.209611°) JURISDICTION: SAWYER COUNTY COUNTY: SAWYER GROUND ELEVATION: 1271'± AMSL OCCUPANCY TYPE: UNMANNED A D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION CONSTRUCTION TYPE: 110 GROUP: U II CODE COMPLIANCE II ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE WISCONSIN COMMERCIAL BUILDING CODE BUILDING/DWELLING IBC 2015 STRUCTURAL IBC 2015 MECHANICAL IBC 2015 ELECTRICAL NEC2017 II CONTACT INFO. II A&E FIRM: JACOBS TELECOMMUNICATIONS 525 W, MONROE STREET SUITE 1600 CHICAGO, IL 60661 CONTACT: MICHAEL STREET PHONE: (315) 240 4776 AT&T CONSTRUCTION MANAGER: 95 W ALGONQUIN, ARLINGTON HEIGHTS, IL CONTACT: DEBBIE MACKENZIE PHONE: (563) 506-0508 SITE NAME: CHIPPEWA SITE ID: WIL03222 FA NUMBER: 10587505 USID: 295664 IWM JOB NUMBER: WSCHI0043414 10424W STATE HIGHWAY 27/70 RADISSON, WI 54867 SAWYER COUNTY EXISTING 195' SELF SUPPORT ERICSSON NETWORK MODERNIZATION AREA MAP LOCATION MAP WIL03222 WIL03222 CHIPPEWA CHIPPEWA I I i� fF7 Il NO SCALE NO SCALE DRIVING DIRECTIONS DEPART 95 W ALGONQUIN RD ARLINGTON HEIGHTS, IL 60005 GET ON 1-90 W FROM IL-62 E 1 HEAD NORTHEAST 2, TURN RIGHT TOWARDS RESERVE DR 3. TURN LEFT ONTO S RESERVE DR 4. TURN RIGHT ONTO IL-62 E 5. TURN RIGHT ONTO S ARLINGTON HEIGHTS RD 6. USE THE RIGHT LANE TO MERGE ONTO 1-90 W VIA THE RAMP TO 7. MERGE ONTO 1-90 W TOLL ROAD 8, KEEP LEFT TO STAY ON 1-90 W TOLL ROAD ENTERING WISCONSIN 9. KEEP RIGHT TO CONTINUE ON 1-94 W 10. TAKE EXIT 88 FOR US-10 E TOWARD FAIRCHILD 11. TURN RIGHT ONTO US-10 E/10TH ST PASS BY HARDEE'S (ON THE RIGHT) 12. TURN LEFT ONTO CO RD 13. TURN RIGHT ONTO US-12 E 14. TURN LEFT ONTO WI-27 N/N BILLS ST CONTINUE TO FOLLOW WI-27 N 15- TURN RIGHT ONTO WI-27 N/BRIDGE ST CONTINUE TO FOLLOW WI-27 N 16, TURN LEFT ONTO WI-27 NAM-70 WANI-70 TRUNK W TO DESTINATION ON RIGHT PROJECT DESCRIPTION INSTALL REMOVE • INSTALL (3) NEW 4471 B30 RRHS • REMOVE THE EXISTING NOKIA RADIOS • INSTALL (3) NEW 4494 B141B29 RRHS • REMOVE THE EXISTING NOKIA BBUS • INSTALL (3) NEW 4490 85/812 RRHS • INSTALL (3) NEW 4890 B25/1366 RRHS • INSTALL (6) NEW RRH BACK TO BACK BRACKETS • INSTALL (6) NEW 10' RRHS MAST RELOCATIONS • INSTALL THE NEW BBUS IN THE WUC • RELOCATE THE NNH4-65C-R6-V3 ANTENNAS CIVIL WORK TO BE COMPLETED FIRST PER AT&T. NOKIA GROUND EQUIPMENT STAYS UNTIL ALL ERICSSON UP TOP IS DONE & INTEGRATION IS SUCCESSFUL, CONTRACTOR TO VERIFY TEMPORARY SOLUTION WITH CONSTRUCTION MANAGER PRIOR TO BEGINNING OF PROJECT, THE PROPOSED PROJECT FOR THIS SITE INCLUDES: DRAWING INDEX 'SHEET # SHEET DESCRIPTION REV. # I T-1 TITLE SHEET 0 GN-1 GENERAL NOTES 0 C-1 AERIAL MAP 0 C-2 SITE PLAN 0 C-3 EQUIPMENT LAYOUT 0 C-4 ELEVATION PLAN 0 C-41 ANTENNA AZIMUTH PLANS 0 C-5 EQUIPMENT DETAILS 0 E-1 SITE DATA INPUT 0 RF-1 ANTENNA INFORMATION CHART & PLUMBING DIAGRAM 0 A/E DOCUMENT REVIEW STATUS TITLE SIGNATURE DATE AT&T CONSTRUCTION MGR: JACOBS PM: RF ENGINEER: ZONING APPROVAL: SITE ACQUISITION: PROPERTY OWNER: STATUS CODE: 1 I I ACCEPTED: WITH OR NO COMMENTS, CONSTRUCTION MAY PROCEED 21 1 NOT ACCEPTED: RESOLVE COMMENTS AND RESUBMIT ACCEPTANCE DOES NOT CONSTITUTE APPROVAL OF DESIGN, CALCULATIONS, ANALYSIS, TEST METHODS OF MATERIALS DEVELOPED OR SELECTED BY THE SUBCONTRACTOR AND DOES NOT RELIEVE SUBCONTRACTOR FROM FULL COMPLIANCE WITH CONTRACTUAL OBLIGATIONS CALL DIGGERS HOTLINE CALL (800) 242-8511 CALL 3 WORKING DAYS BEFORE YOU DIG! ,jacobs® Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, #1600 CHICAGO. IL 60661 at&t Your World, Delivered O o �� 00 Lr) Ln (` w ^ a W rr W O r II PROJECT NO: EPT6IL01 , I I CHECKED BY: LS H ISSUED FOR: II ppi DATE DE$cRrPTiDN 0 1 11/18/24 WW FOR CONSTRUCTION �►�►���t, it I il�rrrS��� KARL R. z KRA N s: s E-4 06 = � OR H I I UkWE, 5 TFIEY ME ACT{NGUNDE.R THE MRECMR I OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT 1I SHEET NUMBER: IiRVISI(]P+E: 11 T-1 0 PROJECT COMPLIANCE NOTES, NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E G., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE AND IS NOT FOR HUMAN HABITAT ELECTRICAL INSTALLATION NOTES: INSTALL PLASTIC LABEL ON THE METER CENTER TO SHOW "AT&T WIRELESS" PROJECT GENERAL NOTES: (NO HANDICAP ACCESS IS REQUIRED). 1. 2 OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY AT&T TECHNICIANS. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL 3 NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS PROPOSAL, UNLESS DURING APPLICABLE LOCAL CODES EMERGENCY. CONDUIT ROUTINGS ARE SCHEMATIC, SUBCONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT 4 OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED, BLOCKED. 5 ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH 2- THE LATEST AT&T SYSTEM GROUNDING STANDARDS. "TECHNICAL SPECIFICATION FOR WIRING, RACEWAY & SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. CONSTRUCTION OF LTE SITES AND WILL FOLLOW AT&T GROUNDING AND BONDING REQUIREMENTS FOR NETWORK FACILITIES AT&T DOC ID ATT-TP-76416 AND AT&T POLICY ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. LETTER ATT-CEM-13002. 3 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED DURING CABLES SHALL NOT BE ROUTED THROUGH LADDER -STYLE CABLE TRAY RUNGS CONSTRUCTION OPERATION. 7, THE CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS. EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I E, HOTS), GROUNDING AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH PROPER LABELING ID, 145 TYPE FIBER TAG, WITH UV RATED P-TOUCH LABEL. MINIMUM WIDTH OF 1/2". THE 8, INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM DRAWINGS PROVIDED BY IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. THE APPLICANT REPRESENTATIVE. THE CONTRACTOR SHALL NOTIFY TURF VENDOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH PLASTIC TAPE PER COLOR SCHEDULE- ALL EQUIPMENT 9 NO ADDITIONAL PARKING IS PROPOSED. EXISTING ACCESS AND PARKING WILL BE USED. SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY 4' 10 NO ADDITIONAL LANDSCAPING IS PROPOSED AT THIS SITE. RATING AND BRANCH CIRCUIT ID NUMBERS (I.E- PANEL BOARD AND CIRCUIT IDS). 11. ALL COAXIAL CABLE/FIBER AND DC CABLE INSTALLATION IS TO FOLLOW MANUFACTURER'S 5. INSTRUCTION. PANEL BOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE CLEARLY LABELED WITH P-TOUCH LABELS ON 145 TYPE FIBER TAGS. GREENFIELD GROUNDING NOTES: THERE SHALL BE NO USE OF NYLON TIE CABLE FOR INDOOR USE 6. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER, CONTROL AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (#14 AWG OR POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING LARGER), 600 V. OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90- C (WET & DRY) CONDUCTORS IN ACCORDANCE WITH THE NEC AND AT&T GROUNDING AND BONDING REQUIREMENTS FOR OPERATION LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED UNLESS OTHERWISE SPECIFIED, 7 NETWORK FACILITIES ATT-TP-76416 AND AT&T POLICY LETTER ATT-CEM-13002 SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR #2 STRANDED R Q CO ( TINS O THE SUBCONTRACTOR SHALL PERFORM IEEE FALL -OF -POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE LARGER), 600V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION CLASS B STRANDED COPPER CABLE RATED FOR 90° C e 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE SUBCONTRACTOR SHALL FURNISH AND INSTALL (WET AND DRY) OPERATION LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED UNLESS OTHERWISE SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS SPECIFIED - THE SUBCONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (#14 AWG OR 9 CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO LARGER), 600 V. OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90° C (WET AND DRY) THE CONDUIT AND PROVIDE TESTING RESULTS OPERATION WITH OUTER JACKET LISTED OR LABELED FOR THE LOCATION USED UNLESS OTHERWISE SPECIFIED- 10 METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY T CONTINUOUS WITH LISTED ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH MINIMUM #2 AWG COPPER WIRE UL AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 75° C (90° C IF AVAILABLE) APPROVED GROUNDING TYPE CONDUIT CLAMPS RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE 11 METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR TIN AND NEC. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E. RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS 12 EACH CABINET AND FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #2 TIN STRANDED COPPER FOR INDOOR/ROOFTOP ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT) OR RIGID NONMETALLIC CONDUIT (RIGID PVC, 13 APPLICATIONS; #2 AWG SOLID TINNED COPPER FOR OUTDOOR GROUND CABINETS. SCHEDULE 40) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS, 14 CONNECTIONS TO THE GROUND BAR SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) SHALL BE USED FOR OUTDOOR LOCATIONS ABOVE GRADE. ON OPPOSITE SIDE OF THE GROUND BAR ARE PERMITTED RIGID NONMETALLIC CONDUIT (I E. RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80) SHALL BE USED UNDERGROUND, ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED CONCRETE IN AREAS OF (2) CONDUCTORS OF #2 AW3 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED, HEAVY VEHICLE TRAFFIC USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION ADEQUATELY SUPPORTED- OCCURS OR FLEXIBILITY IS NEEDED. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE- CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED SET SCREW FITTINGS ARE NOT ACCEPTABLE ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS; A MINIMUM OF (2) CRIMPS AND WINDOWLESS LUGS FOR OUTDOOR APPLICATIONS AND WINDOWED CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND LUGS FOR INDOOR APPLICATIONS. NEC. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE WIREWAYS SHALL BE EPDXY -COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS, GROUNDING RING. SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER). '°` APPROVED ANTIOXIDANT COATINGS (I E. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET A AND BOLTED GROUND CONNECTIONS- STEEL. SHALL MEET OR EXCEED UL 50 AND RATED NEMA 1 (OR BETTER) INDOORS OR NEMA 3R (OR BETTER) OUTDOORS. B ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA 1 (OR BETTER) INDOORS OR WEATHER PROTECTED (WP OR BETTER) N MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED OUTDOORS R TO THE GROUND RING, IN ACCORDANCE WITH THE NEC AND AT&T GROUNDING AND BONDING REQUIREMENTS R FOR NETWORK FACILITIES ATT-TP-76416 AND AT&T POLICY LETTER ATT-CEM-13002 NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) T INDOORS OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. T BOND ALL METALLIC OBJECTS WITHIN 6 FT. OF MAIN GROUND WIRES WITH T 1-#2 AWG TIN-PLATED COPPER GROUND CONDUCTOR THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR BEFORE R COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS- E GROUNDS FOR INDOOR SITE EQUIPMENT SHALL BE LANDED ON THE APPROPRIATE SECTION OF THE CRGB OR A HALO AS PER ATT-TP-76416 AND AT&T POLICY LETTER ATT-CEM-13002. THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD AGAINST LIFE AND PROPERTY, E GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE B ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC S CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS, WHEN IT IS REQUIRED TO BE G HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, GENERAL NOTES FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: TURF VENDOR- JACOBS TELECOMMUNICATIONS CONTRACTOR- GENERAL CONTRACTOR (CONSTRUCTION) OWNER- AT&T OEM- ORIGINAL EQUIPMENT MANUFACTURER PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS- ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES- SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. DRAWINGS PROVIDED HERE ARE NOT TO SCALE AND ARE INTENDED TO SHOW OUTLINE ONLY UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. "KITTING LIST" SUPPLIED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT WILL BE SUPPLIED BY TURF VENDOR. ITEMS NOT INCLUDED IN THE BILL OF MATERIALS AND KITTING LIST SHALL BE SUPPLIED BY THE CONTRACTOR_ THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE, IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE TURF VENDOR. CONTRACTOR SHALL DETERMINE ACTUAL ROUTINGF CONDUIT, POWER AND T1 ABLE GROUNDING O CO U CABLES, OU G CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWINGS THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY- ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. CONSTRUCTION SHALL COMPLY WITH AT&T AND MANUFACTURER SPECIFICATIONS ALL ITEMS REMOVED FROM SERVICE ON SITES THAT HAVE AN AT&T ASSET TAG MUST BE LOGGED BACK IN WITH AT&T. DO NOT SCALE DRAWINGS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11x1T CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. ABBREVIATIONS AND SYMBOLS: BBREVIATIONS: SYMBOLS: GL ABOVE GRADE LEVEL S/(, SOLID GROUND BUS BAR TS BASE TRANSCEIVER STATION E) EXISTING S/N SOLID NEUTRAL BUS BAR MIN, MINIMUM .T.S. NOT TO SCALE i` SUPPLEMENTAL GROUND CONDUCTOR EF REFERENCE F RADIO FREQUENCY' 2-POLE THERMAL -MAGNETIC CIRCUIT 0 B.D. TO BE DETERMINED B, R. TO BE RESOLVED YP TYPICAL 0-0 EQ REQUIRED GR EQUIPMENT GROUND RING WIG AMERICAN WIRE GAUGE 9 MGB MASTER GROUND BAR G EQUIPMENT GROUND CW BARE COPPER WIRE AD SMART INTEGRATED ACCESS DEVICE EN GENERATOR ❑ �R INTERIOR GROUND RING (HALO) BS RADIO BASE STATION BREAKER SINGLE -POLE THERMAL -MAGNETIC CIRCUIT BREAKER CHEMICAL GROUND ROD TEST WELL DISCONNECT SWITCH METER 1 :Jacobs® Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, #1600 CHICAGO, IL 60661 at&t Your World Delivered O t` N � � � O ry O 00 a N O Z W F..j O V � Cv W CD O r PROJECT NO: EPT61L01 CHECKED BY: LS ISSUED FOR: tl�Vj DATE I]E9cRtPnoN 0 11/18/24 WW FO CONSTRUCTION ,���►►►G �O� %N rf•e �••' psi i KARL R. ti1 KRATINA E-47006 _ ��. Af 1liIIlRTI..I %�� V'OLATION 01 LAW 'OR RSON I I o5 A LI , ARE ACTING UNDER E ALTER PR TOFESS HIS DOOCNM NTGGINE RTION I I SHEET NUMBER: I Ilk; IS] IIGN-110 B.D. TO BE DETERMINED B, R. TO BE RESOLVED YP TYPICAL 0-0 EQ REQUIRED GR EQUIPMENT GROUND RING WIG AMERICAN WIRE GAUGE 9 MGB MASTER GROUND BAR G EQUIPMENT GROUND CW BARE COPPER WIRE AD SMART INTEGRATED ACCESS DEVICE EN GENERATOR ❑ �R INTERIOR GROUND RING (HALO) BS RADIO BASE STATION BREAKER SINGLE -POLE THERMAL -MAGNETIC CIRCUIT BREAKER CHEMICAL GROUND ROD TEST WELL DISCONNECT SWITCH METER 1 :Jacobs® Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, #1600 CHICAGO, IL 60661 at&t Your World Delivered O t` N � � � O ry O 00 a N O Z W F..j O V � Cv W CD O r PROJECT NO: EPT61L01 CHECKED BY: LS ISSUED FOR: tl�Vj DATE I]E9cRtPnoN 0 11/18/24 WW FO CONSTRUCTION ,���►►►G �O� %N rf•e �••' psi i KARL R. ti1 KRATINA E-47006 _ ��. Af 1liIIlRTI..I %�� V'OLATION 01 LAW 'OR RSON I I o5 A LI , ARE ACTING UNDER E ALTER PR TOFESS HIS DOOCNM NTGGINE RTION I I SHEET NUMBER: I Ilk; IS] IIGN-110 BREAKER SINGLE -POLE THERMAL -MAGNETIC CIRCUIT BREAKER CHEMICAL GROUND ROD TEST WELL DISCONNECT SWITCH METER 1 :Jacobs® Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, #1600 CHICAGO, IL 60661 at&t Your World Delivered O t` N � � � O ry O 00 a N O Z W F..j O V � Cv W CD O r PROJECT NO: EPT61L01 CHECKED BY: LS ISSUED FOR: tl�Vj DATE I]E9cRtPnoN 0 11/18/24 WW FO CONSTRUCTION ,���►►►G �O� %N rf•e �••' psi i KARL R. ti1 KRATINA E-47006 _ ��. Af 1liIIlRTI..I %�� V'OLATION 01 LAW 'OR RSON I I o5 A LI , ARE ACTING UNDER E ALTER PR TOFESS HIS DOOCNM NTGGINE RTION I I SHEET NUMBER: I Ilk; IS] IIGN-110 PROJECT NO: EPT61L01 CHECKED BY: LS ISSUED FOR: tl�Vj DATE I]E9cRtPnoN 0 11/18/24 WW FO CONSTRUCTION ,���►►►G �O� %N rf•e �••' psi i KARL R. ti1 KRATINA E-47006 _ ��. Af 1liIIlRTI..I %�� V'OLATION 01 LAW 'OR RSON I I o5 A LI , ARE ACTING UNDER E ALTER PR TOFESS HIS DOOCNM NTGGINE RTION I I SHEET NUMBER: I Ilk; IS] IIGN-110 CENTER OF I P.NTEIJNP, r G.A%IMA 1 = SECTOR 290 olkk IF ,�.. �. s is y � � F r y • � I 1 �, � • P' � -� W . Y r �• r�••w y+ 4 4 �lip • ! . y AERIAL MAP -jacobs® Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, #1600 CHICAGO. IL 60661 at&t Your World, Delivered IF ow .. _ , ss.... ..., s �'•• d CENTER. OF AIJTENNA ALPHA L SECTOR 60 a ' 4. All Ln P-( ' �$' ice, _ (� it ► . lf. � , � t � H 1-4 E-I v� C7 y' +� + , w ti. T a • � , � 1 , � PROJECT NO: EPTGILOl CHECKED BY: LS 1 � r EV q ISSUED DATE 11/18/24 FOR: PR DESCRIPTION WW FOR CONSTRUCTION .I. . . %I - Y i Y *Alp 0 • KARL R. y5 �'� C O H IJ CENTER OF _ ANTENNA . , , :� !'fir/1 �O•....... ,`\\\ BETA SECTOR 190 i x1 .� {5 , r fP . VIOLATION OF LAW FOR ANY PERSON, UIJ- -- THE/ ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET NUMBER: REVIRON. SCALE: NTS 1 - O NOTE: Jacobs® THIS SITE DESIGN HAS BEEN PREPARED WITHOUT THE BENEFIT OF AN AS -BUILT SURVEY. THE INFORMATION SHOWN Challenging today. IS NOT BASED ON AN ACTUAL FIELD SURVEY- THE Reinventing tomorrow. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS. ALL MEASUREMENTS SHOWN HEREON WERE NOT FIELD VERIFIED, 525 W. MONROE STREET, #1600 AND SHALL BE VERIFIED BY CONSTRUCTION MANAGER PRIOR CHICAGO, IL 60661 TO BEGINNING CONSTRUCTION. THIS PLAN WAS CREATED 100'-0"1 FENCED COMPOUND BASED ON INFORMATION GATHERED FROM PREVIOUS DRAWINGS, AERIAL IMAGING, AND OTHER ONLINE INFORMATION- CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS SHOWN HEREON. at&t CONTRACTOR TO VERIFY ALL PROPOSED AND Your World. Delivered. EXISTING ANTENNAS, MOUNTS AND CABLES WERE EXISTING CHAIN -LINK CONSIDERED AND PASSED A STRUCTURAL SECURITY FENCE ANALYSIS PERFORMED BY A LICENSED ENGINEER PRIOR TO INSTALLATION EXISTING GRAVELED COMPOUND YI/ FINAL CABLE CONFIGURATION: CONTROL CABLE/POWER DIAMETER: 0 96" (24.3 MM) CABLE - (#6 AWG DC TRUNKS) (2) FIBER/HYBRID DIAMETER: 0.41" (10.3 MM) FIBER - (24 PAIR FIBER TRUNKS) @ 230't } 1 EXISTING AT&T ICE BRIDGE ALL EXISTING CABLES TO REMAIN EXISTING AT&T j GENERATOR ON STEEL ^ PLATFORM Z O 00 LnIt � Lr P. —T - o w a L EXISTING AT&T v Ln EXISTING 195' ml r WUC ON STEEL " ow r- W O SELF SUPPORT TOWER (PLATFORM 0 LL I�1 H r Z V o ti AL w /J EXISTING POWER -- EXISTINGICEJ" BRIDGE (TYP) I'HOJ L•;C'1' NO: EPT61LO1 TRANSFORMER i - EXISTING UTILITY '� EXISTING CHECKED BY: LS H-FRAME (TYP) 1 V-6 X 25'-0" ISSUED FOR: EXISTING SINGLE fI J SHELTER (OTHER li CARRIER) EV DATE GESCRFPT10N d 0 11/18/24 WW1 FOR CONSTRUCTION SWING ACCESS GATES 1I r EXISTING r } 11111111j['1, SWINGCESS 'llll{{ti G 0 �U%•���i/ ACOUBLE GATES \`7\��,,5 .............. �. r' KARI R. KRATINA v ` �; E-47006 _�: A DR- H w— Ir ,C�ti• � ,N� S 1/11111 1111110 0' 8' 16' 32 46' R ANOW7ll7N L7F L.4'1'f FOR N7+'P6RC7N, K aS ZrEV AaE ACTING91.1 EBRfGTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT - SITEF-r NUMBER! RPVTS1S1'0N; C-2 LL!! I22" FSITE PLAN 11 SCALE: V'-0" /16" x34" SCALE: = 1'-0" 2"x34 /8" • THESE DRAWINGS DO NOT REPRESENT THE STRUCTURAL INTEGRITY OF THE TOWER. THE ANTENNAS SHOWN ARE SCHEMATIC AND DO NOT REFLECT THE ACTUAL CONFIGURATIONS REQUIRED. JACOBS HAS NOT PERFORMED A STRUCTURAL ANALYSIS OF THE TOWER. CONTRACTOR TO REFER TO ANALYSIS BY OTHERS. ANY MODIFICATIONS TO THE TOWER OR FOUNDATION NEEDED SHALL BE PERFORMED PRIOR TO THE INSTALLATION OF EQUIPMENT SHOWN ON THESE DRAWINGS. • THE CONTRACTOR SHALL REFER TO THE STRUCTURAL ANALYSIS OF THIS TOWER SITE FOR THE APPROVED LOCATION AND CONFIGURATION OF ALL ANTENNAS. ALL ANTENNAS MUST BE MOUNTED IN STRICT ACCORDANCE WITH THE STRUCTURAL ANALYSIS. • CONTRACTOR TO VERIFY ALL HEIGHTS AND AZIMUTHS PRIOR TO BEGINNING CONSTRUCTION, AND NOTIFY ENGINEER WITH ANY DISCREPANCIES. • REFER TO STRUCTURAL ANALYSIS TO DETERMINE FEEDLINE PLACEMENT. TOP OF STRUCTURE ELEV. = 200'-0" TOV.P OF TOWER ELE= 195'-0" EXISTING ANTENNAS (OTHER CARRIER) AT&T ANTENNA TIP HEIGHT ELEV= 184'-0" (P)&(EE AT&T ANTENNAS RAD CENTER = 180'-0" EXISTING 195' SELF SUPPORT TOWER FINAL CABLE CONFIGURATION: —� CONTROL CABLE/POWER DIAMETER: 0.96" (24.3 MM) CABLE - (#6 AWG DC TRUNKS) (2) FIBER/HYBRID DIAMETER: 0,41" (10.3 MM) FIBER - (24 PAIR FIBER TRUNKS) @ 230't ALL EXISTING CABLES TO REMAIN EXISTING AT&T ICE BRIDGE GROUND ELEV, = 0'-0" AGL !w�f� 01 2/C-4.1 EXISTING LIGHTING ROD w �. zaz O W N Z W w U FINAL EQUIPMENT CONFIGURATION: (6) EXISTING ANTENNAS (2) EXISTING DC-9 SURGE ARRESTORS (12) PROPOSED RRH's (6) PROPOSED RRH DUAL MOUNT BRACKETS EXISTING FENCE (TYP ) 0' 8' 16' 32' TOWER ELEVATION I 11 SCALE: ,// ""=,'-0"I I 22"04x34" SCALE: 1/8= 1'-0" ,jacobs® Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, #1600 CHICAGO, IL 60661 at&t Your World Delivered O t` 1 P4 O 00 Vr Ln i� W N o �, �� a x z w Q� W O II PROJECT NO: EPT6IL01 I CHECKED BY: LS ISSUED FOR: REV DATE 0RVM DESCRIPTION 0 11/18/24 WW FOR CONSTRUCTION 41��r S G 0011 KARL R. ti f KRA NA E-4 06 r ORT H , `( 1111111�����, i;, 11NC65'3 THEY APE ACTING tW I!R TiiL 00MCTItlN OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBEC-4IRE71 R: ALL EXISTING RRHS & ASS- 1-MOUNTING HARDW/ TO BE REMO\ (TYP. ALL SECTO (1) EXISTING NNH4-65C-R6-V3 ANTENNA TO BE RELOCATED TO POS 3 (TYP. PER SECTOR) (1) EXISTING NNH4-65C-R6-V3 ANTENN/ TO BE RELOCATED TO POS (TYP, PER SECTOR �\ (GAMMA) 2900 AZIMUTH C, f (1) EXISTING DC-9 SURGE ARRESTOR TO RELOCATED (TYP OF 2) NOTE: ALL DIPLEXERSITMA'S & ASSOCIATED MOUNTING HARDWARE TO BE REMOVED. B2 (BETA) B1 1900 AZIMUTH 1 2 (ALPHA) 60° AZIMUTH A3 A4 f NOTE: INSTALL PROPOSED EQUIPMENT MOUNTED PER MOUNT STRUCTURAL ANALYSIS REPORT BY JACOBS TELECOMMUNICATIONS, INC. DATED 08/15/24. REFER TO REPORT FOR ADDITIONAL REQUIREMENTS. NOTES: ALLSTRUCTURAL WORK IS TO BE COMPLETED PRIOR TO RF WORK STARTING. CONTRACTOR TO ENSURE THAT THERE IS NO ANTENNA SKEW. FOR THE INSTALLATION OF THE RRHS, INSTALL NEW 2.0 STD (2.375" OD) x 120" LONG RRH PIPES WITH CROSSOVER BRACKETS (SITEPR01 PART NO. SCX1-K OR APPROVED EQUIVALENT). MOUNTED ON NEW COMMSCOPE RR-FA2 RRH MOUNTING BRACKET OR APPROVED EQUIVALENT. DO NOT EXCEED MOUNTING MORE THAN 2 1 SURGE PER PIPE. f 24 S AiN C4 . 1 (1) EXISTING NNH4-65C-R6-V3 ANTENNA elC� RELOCATED FROM POS 4=� Al �A�'p (TYP. PER SECTOR) ��`�4 ta 2�p} , C3 ?� (ALPHA) ROTATE EXISTING SECTOR MOUNTS TO \. Or- 60° AZIMUTH ACHIEVE FINAL AZIMUTH / 2� A2 9O 11 INSTALL (1) NEW 4494 B14/B29 RRH & / �\ (GAMMA) (1) NEW 4890 8251B68 RRH ,;II. / 290° AZIMUTH (TYP PER SECTOR) C2 I \ INSTALL (1) NEW 4490 B5IB12A RRH ' \ \ A3 & (1) NEW 4471 B30 RRH (TYP PER SECTOR) � i \ (1) EXISTING NNH4-65C-R6-V3 ANTENNA —F 1 RELOCATED FROM POS 2 C1 ► J \ (TYP. PER SECTOR) A4 N ! a , . I �\ y04 B3 f= 62 B1 a;� / Na (1) EXISTING DC-9 SURGE ARRESTOR (TYP OF 2) ,jacobs® Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, #1600 CHICAGO, IL 60661 00 at&t YourWorld Delivered O t` N � 00 0 Ln v O 00 L�r �D �� w C7 Ln w x w ,'mow V �Q � w O PROJECT NO: EPT11L01 CHECKED BY: LS ISSUED FOR: Lv DATE R DESCRIPTION 0 11/18/24 WW IFOR CONSTRUCTION (BETA) 190° AZIMUTH 0' 1' 2' 4' 6' EXISTING ANTENNA AZIMUTH PLAN 122N 4SCALE:3// "=1--o"I 1 1 PROPOSED ANTENNA AZIMUTH PLAN 1 22N 3/16" 1-0.1 I 22'x34' SCALE: 3/8' = 1'-0' 22"x34' SCALE: 3/B' = 1'-0' ►►►1l l u 111111,� ,11" KARL R. KRATINA E-47006 NORTH I :►_ Y[ . A VIOLATION OF LAW FOR ANY PERSON, f7N TH EYARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET NUMBER: REVISION'. C-4.1 0 I PARTS LIST ITEM OTY PART NO PART DESCRIPTION LENGTH UNIT WT NET Wi -�- EXISTING PIPE MOUNT 1 1 SCX1 CROSSOVER PLATE 3.71 3.71 2 4 X-UB1212 1/2" X 2-1/2" X 4-1/2" X 2" U-BOLT (HDG.) 0.63 2 50 MOUNT BRACKETS. INSTALL PER MFG, SPECS. 3 B G12FW 1/2" HDG USS FLAT WASHER 0.03 0 27 4 8 G12LW 1/2" HDG LOCKWASHER 0.01 Oil 5 B G12NUT 1/2" HDG HEAVY 2H HEX NUT 0.07 0 57 TOTAL Wi. # 7 16 PROPOSED ANTENNA 2 3 4 5 I X2 X2 X2 2-3/8" 0 D ANTENNA PIPE (ORDERED SEPARATELY) MOUNT ANTENNA IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED PROCEDURE PROPOSED JUMPER CONNECTION, (TYP) � 2-3/8" O.D. ANTENNA PIPE�y I (ORDERED SEPARATELY) I X2 X2 X2 DETAIL FOR MOUNTING PURPOSES ONLY. MAINTAIN MIN. BEND RADIUS, PER MANUFACTURER'S SPECIFICATIONS � 2 3 4 S NOT ALL MEMBERS SHOWN ANTENNA MOUNTING DETAIL ISCALE:NTSI1 SITEPR01 SCX1-K SCALE: NTS 2 NOT USED SCALE: NTS 3 PROPOSED MOUNT PIPES PROPOSED SCX1-K OR APPROVED EQUIVALENT MOUNT ASSEMBLY PROPOSED RRHs EXISTING V-FRAME ARM PROPOSED DUAL RRH NOT USED SCALE: NTS 4 NOT USED SCALE: NTS 5 BRACKET ■ EXISTING V-FRAME ARM PROPOSED SCX1-K OR APPROVED EQUIVALENT MOUNT ASSEMBLY SURGE PROTECTOR & RRHS LAYOUT SCALE: NTS 6 NOT USED SCALE: NTS 7 NOT USED SCALE: NTS 8 Jacobs® Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, #1600 CHICAGO. IL 60661 at&t ., Your World Delivered 0 00 00 � V O L�r � u7 Ln ao x o z w Q H V) c� ci z V 0 w PROJECT NO: EPT61L01 CHECKED BY: LS 0. V ! =? KKARL R. RATINA •�• �IVOR H �; 0 �- S R A VIOLATION OF LAW FOR ANY PERSON, UN 9$TH EYARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET NUMBER: REVISION: -5 0 ISSUED FOR: EV DATE R DE9CRIPTI0IJ D 11/18/24 WW FOR CONSTRUCTION Region; Milli. !Market: 1LLINC1iAryNaCDNSIN FA: t05875" -USID: 296004 Location Name: IM1.117222 Data Cale Completed'. lf/17/2024 ComplO[od 61 KF 15 r li PACE JOE 10: MR090116531 .Job Description: RBRN"w/Erbseon IFleld Notes: STEP 2: ENTER DC PLANT TYPE FROM 13ROPAOWN MENU, r61114 N. -24V or A8V DC PLANT CAN BE SELECTED FOR ANY MANUFACTURER'S DC MAfTI Vcm• $ TO.40VOC Ord dwr NO%— 5100 Ly410m 525A w-58V LYOHV i 48V PRIMARY GC PLANT SPECIFIGDf•-.^...^..�. iTA: PLANT Ci7NF1 aK7Fi UPATCAN BE RF..V's YrED ON DC PLANT WORISSHEET( STEP ZAc THIS STEP ONLY SHOWN IF -4ENEiRIC' OC PLANT PLANT TYPE HAS BEEN SELFCTF.D: STEP 28: TH15 STEP ONLY SHOWN IF TYCO CPS2424 DC PLANT PLANT TYPE HAS BEEN SELECTED: STEP 3: DO YOU WANT TO CONFIGURE A STANDARD STAND-ALONE DC CONVERTER SYSTEM? It ]VOTE: IF YOU SELECT "Y' ANY INTEGRATED DC PLANT CONVERTER OPTIONS WILL BE BYPASSED STEP 4 ENTER INDOOR SITE BUILOING,$HELTER DATA. (Square footage used for Interior AC lighting LOAD calculation) SELECT SITE ENCLOSURE TYPE 8 SQE-I WUC 1 r nnl STEP 5: ENTER SITE HVAC SYSTEM DATA: Data aUlomaliclly entered for Enclosure Selected, See AG Load Estimate tab for loads SITE DATA INPUT WORKSNEET . INDOOR SITE POWER ESTIMATE TOOL _ I A8V PRIMARY VOLTAGE DC PLANT SPECIFIED +24VDC EQUIPMENT LORD: 0 WATTS e 0 AMPS at -24V -48VDC EQUIPMENT LOAD: 12515 WATTS 232 AASPS at 46V -58VDC EQUIPMENT LOAD: a WATTS - 0 AMPS at.58V NO SECONDARY 58V LOADS,- DC CONVERTER SYS TEM NOT REQUIRED TOTAL PRIMARY 48V LOAD: 12515 WATTS - 1 232 AMPS at d8V DC PLANT Verbv STO 49YDC Outdoor MRS. a 51W Sysum 625A w-SaV CONY -40 RECTIFIER$ REQUIRED INe11: -UV RECTIFIER SLOTS: B 18 CONY, TYPE: VNI'li IL SLOTS - RKWt Y RECT SLUTZMVELF CAN Be USED Fi71t CONY -58V CONVERTERS REQUIRED: -58V SLOTS: 0 (NOLZNVERTERBREOU11TFDj 12 N.DEC CONVERTERS REQUIRED} ESTIMATED BATTERY RESERVE TIME 2100AH48VSTRINGS= 237 HOURS RONSRE GENERATOR-2 HOUR MINIMUM) 4Y ENcttwn V LTE 45 IL Multi -Slid EQUIPMENT 0 Erll -son LTE N?8SG601 FIEW • I AUL 0 Ene-cm LTE RBS6601 BBU - 2 DUL 0 Lixh car W/COMA Rfi8 71 - 1 WVY 0 Ericsson LTE l918ZNDI Eau- tDLfS 0 Era:ason LTE 1311$B861 BBU -2DIiS 1 . Eo.-se," XMU 0 ] Ericsson LTE RBS5216 0 1 P614 P0A C.)rd 0 JOOD BBU Card 0 14'rc45 BBU Catd p JEU5 BBU Card 2 6831 BBU Card p 'fi&73 RnuFsr 0 'r:la BBU Card I :'' >i1 b Boa I: W IWNV 0 - 1RRUS 11 a RRLLS12.. Al 0 RRl4$ 32 B66 0 RRUS 32 B20 0 JARIfS 32 62 0 RRUS44[rx96 B RRu 441s Bzs 0 STEP 6: ENTER SITE STATIONARY GENERATOR DATA 0 DOES SIfE HAVE A gTATPNARY GENERATOR'1 Y I AC or DC: AC I GENERATOR SIZE {KW): 20 0 ESTIMATED CAPACITY REGUIRED: 11 KW OENSfi CAP 'At',ITY SUFFICIENY 0 0 ENTER SITE BATTERY CONFIGURATION DATA: SELECT SINGLE STRING BATTERY CAPACITY IAHI' 190 SPECIFY TOTAL QUANTITY OF BATTERY STRING$: 2 TOTAL SITE BATTERY CAPACITY AHI: 3" NOTE STANDARD DATTERY CAPACITY HAS BEEN SPECIFIED NOTE 12 VOLT NlOsK)Rj fIC MTTTU:E0 41-,.1rt pe, 4EY•13h,:N ESTIMATED BATTERY RESERVE.IgdE �2-4 HOUR$ I fSTE GENSETI SITES WITH STATIONARY GENSETS . Equipped with Veniv DC Plant (NED 20068) equipped with 200 amp Gallery disconnect breakers shall receive no greater than 2 1;helves of 180 AH batteries - All other local ons with legacy DC plants (typically equipped with battery disconnect breakers <200 amps) shall receive no greater than 3 shelme or 180 AH batteries ALL SITES WITHOUT A STATIONARY GENSET - Shall be engineered with 4 hours of beHary reserve. ANY QUESTIONS PLEASE CONTACT RICK BADGERO (RB6620@ATT CON) 0 p' 4478 B12 400 B74 4478 B5 S E2B2O 5 2012 B29 S 4449 B5/B12 a AIR 3246 BZ5" IkTa 0 Ai R 5331 radio 0 AIR 12AI main 0 AIR 1641 8251B66 p LPFkU 4.410 BSla12 0 LPRIJ 4420 102FASES 0 RRUS 2203 B14 p n1f+64RB R4B p AIR 6419 B77 p Aar 6449 B77 0 RRD IIES1 OFF 0 1HRUS 4460 132/1366 0 JAIR W54 B 1 r Wa WA113164110 1n 61 0 ] lA1r 5322 Radio 0 ] Indic 4435 U77D 9 �.RRU 4467 n77 Dual Gh-d.'3 4TGr 3 I GUT jP#(i "7..1 B5/B 12 Dual band p� RRU 4408 3 A5lkir Pn.n Rann 3 OUT lRRU 4890 B21B5-B66 48 0 48p 0 48 0 45 0 48 0 48 0 48 0 46 If 49 D 48 0 40 0 48 0 4a 0 41 D 48 0 41 0 48` n 4s 0 44 a 48 0 4S 0 46 0 48 0 0 D 48 0 48 0 48 0 48 a 4e a 49 0 411110 48 0 48 0 48 2967 48 0 LTE 4d A NUBSId EDUIPMENT I. jA-LU .5926 LTE OSU 1w�rria. 3r:CEr4•u) 48 q p NOhia F$M-4 Chassis (LTE WIA; ASIAET. ABrAs.31 1 48 0 p 1 Nokia FSMA Chassis 50 AM IA ASIKt} AULe31 1 48 1 0 ❑ JV{UIL71 I 48 r 0 0 nRnta!"l j 46 0 0 j .' Il!n) 40 1 p IL+9) 48 p A i.'X51 B66(li 48 0 a 2X6011-81 49 0 0 an(wtj 48 0 0 I4x25 1330.I1_3I 48 0 0 IZX63841(.RI 0.8 0 0 I4X30 B25 RO) id 0 e ' iOX45 SCnP jL2)48 0 If IFlexi B14 FREI 48 q 0 MS -le BS AHCA 48 0 a AW13 le 664 ANN& 40 0 0 A cA4 (Iftw) B25 AHFB 4a D 0 ArF$,ndfr (IJlcnll BEO Ali I 48 0 ❑ JAPiSCal. Dual Band 625166 AHFIB 48 0 0 An'",.cala Dual Band B12114 AHLBA 48 0 pAi�S'ra9a ua7 BuLnd B5:2'0 AHdC$ 0 0 IAirsralo An. 30 TiHz X. 48 - 0 0 ! ;AirS aieTnuandd1b81.1102-fAHLBSA u o p I41t$r41n Band 77 AEQK 4a 0 p iAn$ca1M Band T7 A20W 48 0 ❑ NrScd9 MAA n77 AEQK 48 0 0 Alr$calu MAA 177AECWJ 48 0 0 IA,gr"nle 1AAA n7A A6'Oil AS 0 o IAltScale n77 AZOW 48 0 0 jAHSCalp (Mfcre) h7r AWT 40N 4a 0 0 NrScale DS B25W. AHFII 48 n Alrycale DB MAA n77/3 45 GHz AQQQA i 4a 0 72.g2 AMPS ESTIMATED SITE MAX, AC LOAD (AMP81: ESTIMATE 200A SERVICE SUFFICIENT ESTIMATED CAPACITY REWIRED: 11 KIN ON SITE AC GENERATOR CAPACITY: 20 KW ESTIMATE GENSET CAPACITY SUFFICIENT flECOMMENDEUERVIROSYSTEM CCABINET SYS SPECIFIED ENWROMENTAL SYSTEM- CRBINET SYS u A,Vr , rt 2 medu;e mcpa FRAMEI 24 1 0 0 Ai 135 Wall Module 24 0 0 PµtrgrwoA 12 module ri FRAME) 24 p 0 Pnwnrwwrn 90 Wall A, 24 0 R Pdwarda 120 Wall Module 24 0 p Pev/p — 100 W all Module 24 0 p CC1 125 Wan DAB SCPA Module 24 0 OTY ANGLLARY CELL SITE EQUIPMENT VOLTAGE WATTS D •AiLV.'P7D6 SrAtj 41 I a 0 A-LU MPR-9500 MIN Service Switch - MSS 4B 0 0 A-Lu MPR-950OMWOutdoor Unit-ODU 48 0 0 A-Lu MPR-9500 MW MPT-HL (Indoor) 48 0 1 D214D SULDSgMO 44 2On 0 Crsm MW R-2941SIAD 48 0 0 Cisco SWD ASR-90t 48 0 0 Clsw 15310 EOS (SONET) MUX 42 D 0 Cisco 15454 MSP MW RingCents 1 48 0 0 Tru-Position LMU lee 1) 48 0 _ 1 LIE 14E RIC Elherdel NED 48 0 a GENERIC Hµlinglrn Deleclor da 0 0 CJtNlE: IC or T CbnitWlor 48 0 0 GENERIC RXAIT 49 0 a PA NE RIC Smor" Drteblar 4B 0 0 GENERIC TMABy.Tem 49 Q 0 GENERIC Tower Lighllnp (UC) 46 0 0 ;r4L¢i10U 41 0 0 Cisco 2911 4a a 1 .FLX-12 Cabiw 0 320 0 FLY,• b6 Cabinet 48 0 0 IFLX•21 Coblkat 45 0 0 1 FLX42 Cabinet 48 0 D e 0 ,jacobst, Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, 41600 CHICAGO, IL 60661 �. at&t Your World Delivered U M ❑ O p � � E�-/I o 0 (V P4 QJ' � O p In �'1 00 P. V Lr1 ii// W FI� Ly�T V) N � / i n C/)w V x W �Q US DTY A � W O p 0 I SITE DATA INPUT I SCALE: NTS 1 1 1 PROJECT NO: EPT6IL01 CHECKED BY: LS ISSUED FOR: V DATE ❑ESCRIh'tX 0 11/18/24 W V IFOR CONSTRUCTION I KARL R. KRATINA=_ -47006Ir f�� I TT AV1olATIONPF LAW FOR AHY PERSON. LINL THEY AIIE At TING UNDER THE tl11iEC'rION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET NUMBER: REVISION E-1 0 #8AWG DC TRUNK CABLES SHALL ALWAYS BE USED FOR SINGLE BAND RRH's & #6AWG DC TRUNK CABLES SHALL ALWAYS BE USED FOR DUAL BAND & CBAND/DoD RRH's ANTENNA ANTENNA ANTENNA ANTENNA TMAS, RRH's, DIPS DC SURGEIDISTRIBUTION & NUMBER MODEL VENDOR A21MU1H CENTERLINE COAX/DC/FIBER FROM GROUND MODEL NNH4-65C-R6-V3 (1)4471 B30 Al (96"x19,6"x7-8") COMMSCOPE 600 180'-01, (1) 4490 B5/B12 (89 3 LBS) A2 NNH4-65C-R6-V3 (1) 4494 B14IB29 A3 (96"x19.6"x7.8") COMMSCOPE 60' 180'-0" (1) 4890 B25/B66 (89 3 LBS) NNH4-65C-R6-V3 (1)4471 B30 B1 (96"x19.6"x7.8") COMMSCOPE 190, 180'-01, (1) 4490 135/1312 (2) RAYCAP DC9-48-60-24-8C-EV (89.3 LBS) (5) CONTROL CABLE/POWER DIAMETER: 0.96" (24.3 MM) CABLE - B2 (#6 AWG DC TRUNKS) (2) FIBER/HYBRID DIAMETER: 0.41" (10.3 MM) FIBER - NNH4-65C-R6-V3 (24 PAIR FIBER TRUNKS) B3 (96"x19.6"x7.8") COMMSCOPE 1900 180'-01, (1) 4494 B14/B29 @ 230'± (89.3 LBS) (1) 4890 B25IB66 NNH4-65C-R6-V3 (1)4471 G1 (96"x19.6"x7.8") COMMSCOPE 2900 180'-0" (1) 4490 B5/BIB12 (89.3 LBS) G2 = - NNH4-65C-R6-V3 (1) 4494 B14I829 G3 (96"x19.6"x7.8") COMMSCOPE 290° 180'-0" (1) 4690 B25IB66 (89.3 LBS) I12 NOTES 1 VERIFY ANTENNA WITH VERIFY FINAL ATENA MODEL WITH CURRE TTVERSION OF THE AT&T RFDS- II ANTENNA INFORMATION CHART R ET ENRON an mmmmonamoni i il ff2l E15 4472 CPRI/ Dr- r f� Cf�7�1/ SCALE: NTS 1 1 1 PLUMBING DIAGRAM (TYP PER SECTOR) "awh On Nang so on .Ill. B14/B29 44D4 CIRRI/ T D" L A - PCS10,VVS 41390 CPRI{ DC- IP p[NFsbw .,n.11pn d� IDC IEIW" Prpeacclegl Power Pl.nt DC Dlstrlbutloh SCALESCALE:NTS122 -jacobs® Challenging today. Reinventing tomorrow. 525 W. MONROE STREET, #1600 CHICAGO, IL60661 at&t Your World. Delivered. O t` 0 Lr)P. �44 V) N o Q n Iti tl W O r IIIPROJECT 01 CHECKED B EPT6IL ' LS III ISSUED FOR: EV DATE R ❑EELRIPTION 0 11/18/24 WW FOR CONSTRUCTION Go KARL R. KRATJNA 1E-4,706 �0RH r r.. A VIOLATION OF LAW FOR ANY PERSON iril'L'4 THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT SHEET NUMBER: REVISION: RF-1 0