Loading...
HomeMy WebLinkAbout014-942-32-1106-LUP-2024-572Wi1=190Area ' R (Nelson Lake i VICINITY MAP COMPLIANCE CODE ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 2015 IBC NATIONAL ELECTRICAL CODE (NFPA 70, NEC 2017 W/ AMND) 2015 WISCONSIN MECHANICAL CODE (IMC 2015 W/ AMND) 2018 WISCONSIN UNIFORM PLUMBING CODE (UPC) 2015 WISCONSIN ENERGY CONSERVATION CODE (IECC 2015 W/ AMND) 2015 WISCONSIN FIRE CODE (IFC 2015 W/ AMND) WISCONSIN COMMERCIAL BUILDING CODE WISCONSIN UNIFORM DWELLING CODE (UDC) 2015 WISCONSIN FUEL GAS CODE (IFGC 2015 W/ AMND) UTILITY COMPANIES POWER COMPANY: XCEL ENERGY PHONE: (800) 895-1999 TELEPHONE COMPANY: CENTURY TEL PHONE: (800) 201-4102 - IN Lemf ul Landing r� AMERICAN TOWER® ATC SITE NAME: HARD ROCK WI ATC SITE NUMBER: 311256 T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 T-MOBILE SITE NUMBER: Al N0947A SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 SITE CLASS: SELF SUPPORT T-MOBILE CAPACITY-L1900 AMENDMENT PLAN 6790AH SR T 6X24 CONFIGURATION PROJECT SUMMARY PROJECT DESCRIPTION SHEET INDEX SITE ADDRESS: THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED AND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW: SHEET NO: REV: DATE: BY: DESCRIPTION: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 TOWER WORK: G-001 0 1V20/2024 EDNA TITLE SHEET COUNTY: SAWYER GEOGRAPHIC COORDINATES: LATITUDE: 46.08347843 46° 5' .522" N LONGITUDE:-91.51332847 910 30' 47.982" W REMOVE (6) ANTENNA(S), (2) RRU(S), (1) COVP, AND (1) 1-5/8" NSN HIGH CAP HCS CABLE INSTALL (3) ANTENNA(S), (3) RRU(S), AND (1) 2.00" HYBRID TRUNK 6/24 4AWG 90M CABLE EXISTING (3) RRU(S) TO REMAIN GROUND WORK: REMOVE (1) H-FRAME, (1) MODULE STAND, (2) AMOB(S), (1) COVP, (1) DELTA SSC CABINET, (1) ASIK, (1) FSMF, AND (1) CSR 7705 SAR A G-002 G-101 C-102 C-201 11/20/2024 EDNA 11/20/2024 EDNA GENERAL NOTES 0 DETAILED SITE PLAN 0 DETAILED EQUIPMENT PLAN 0 11I20/2024 EDNA 11/20/2024 EDNA TOWER ELEVATION 0 ANTENNA INFORMATION &SCHEDULE GROUND ELEVATION: 1322' AMSL INSTALL (2) ASIL(S), (1) ASIA, (4) ABIL(S), (2) AMIA(S), (1) CSR IXRE V2, (1) DELTA HPL3.05 600A DC CABINET, AND (1) DELTA LB3 C g01 0 11/20/2024 EDNA 0 BATTERY CABINET EXISTING (1) ASIA,_(2) ABIA(S), AND {1) ABIL TO BE RELOCATED — C 501 CONSTRUCTION DETAILS 11/20I2024 EDNA 0 PROJECT NOTES E-501 GROUNDING DETAILS 11/20/2024 EDNA 0 1. THE FACILITY IS UNMANNED. I E-601 PANEL SCHEDULE & ELECTRICAL SCHEMATIC 11/20/2024 EDNA PROJECT TEAM 2• A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE. SUPPLEMENTAL SHEETS (9 PAGES) - — - _ 3. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND TOWER OWNER: APPLICANT: DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE. 4. NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSAL AMERICAN TOWER T-MOBILE CENTRAL LLC IS REQUIRED. 10 PRESIDENTIAL WAY ATTN: BILAL BATROUKH 5. HANDICAP ACCESS IS NOT REQUIRED. WOBURN, MA 01801 1400 OPUS PLACE DOWNERS GROVE, IL 60515 ENGINEER: 6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U.S.C. § 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THAT INVOLVES THE ATC TOWER SERVICES LLC COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF _ 1 FENTON MAIN, STE 300 TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CARY, NC 27511 CHANGE UNDER CFR § 1.61000 (B)(7). PROPERTY OWNER: PROJECT LOCATION DIRECTIONS TREVOR J WHYTE 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 FROM NORTHBOUND 1-35W IN MPLS 55408 GO 26.8 MI: I45W N BECOMES 1-35 N, 37.9 MI. TAKE THE MN-70 EXIT, EXIT 165, TOWARD ROCK CREEK/GRANTSBURG. TURN RIGHT EAST ONTO MN-70 (CROSSING INTO WISCONSIN), 10.6 MI. MN-70 BECOMES WI-70, 19.7 MI. AT SIREN, WI TURN LEFT ONTO 2ND AVE/WI-35ANI-70. CONTINUE —. TO FOLLOW WI-70 E, 2.5 MI. TURN RIGHT TO STAY ON WI-70 - 0.1 MILES PAST LIND RD, GO 23.7 MI. AT SPOONER, WI TURN LEFT ONTO US-63/N RIVER ST. CONTINUE TO FOLLOW US-63 N, GO 28.1 MI. AT HAYWARD, WI TURN LEFT ONTO WI-77ANI-27, 3.6 MI. TURN RIGHT ONTO WI-27, 1.9 MI. LOOK FOR ACCESS ROAD ON RIGHT EAST SIDE OF WI-27 WITH TOWER PEEKING OVER TREES. t n s AMIERICANTO vow c ATC TOWER SERVICES LLC L 1 FENTON MAIN - SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 c r THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR i WHICH THEY ARE PREPARED. ANY USE OR •+ DISCLOSURE OTHER THAN THAT WHICH RELATES i TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. IREV. DESCRIPTION BY DATE A0 FOR CQNSTRUGMN EDNA!1/2p/2Q24 0 _ 0 -- 0 o_ ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 SEAL: ll tt�' j5 C 0 =� SANTHOSHA SHANBHOGUE = _ E-49097 CARY w �. NC.� -.�N,4. >anthos�l�i/a IIUI 1)Ily signed b Santhosha lhanbhog Shanbhogue Date: 2024.11.20 e - T - -Mobilem. ATC PROJ. #: 14907583_GO CUST. ID: HAYWARD WI-ATC 311256 CUST. #: Al N0947A TITLE SHEET SHEET NUMBER: REVISION: G-001 0 GENERAL CONSTRUCTION NOTES: 1 OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY- WILL PROVIDE AND THE CONTRACTOR WILL INSTALL A BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUND BUILD/CO-LOCATE ONLY) B. AC/TELCO INTERFACE BOX (PPC) C ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILDICO-LOCATE ONLY, GC TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION) D TOWERS, MONOPOLES E. TOWERLIGHTING F. GENERATORS S LIQUID PROPANE TANK G ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING H ANTENNAS (INSTALLED BY OTHERS) I. TRANSMISSION LINE J. TRANSMISSION LINE JUMPERS K. TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITS L TRANSMISSION LINE GROUND KITS M HANGERS N. HOISTING GRIPS O. BTS EQUIPMENT 22. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIRED PERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THE CONTRACTOR. 23 CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILE SPECIFICATIONS AND REQUIREMENTS. 24 CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 25 ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND AS SHOWN IN THESE PLANS WEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OR EQUAL, B. ALL COAXUIL/HYBRID CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIAL/HYBRID CABLE (NOT WITHIN BENDS) ELECTRICAL NOTES: 1 ELECTRICAL DESIGN SHALL BE PERFORMED BY ELECTRICAL CONTRACTOR. STRUCTURAL DESIGN SHALL BE PERFORMED BY GENERAL CONTRACTOR ELECTRICAL CONTRACTOR SHALL ENSURE THAT ALL WORK COMPLIES WITH ALL APPLICABLE LOCAL AND STATE CODES AND NATIONAL ELECTRICAL CODE, 26. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. 2 THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT 27 CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 46 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR SEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW AND ALL SUGGESTED ELECTRICAL ELEMENTS (SUCH AS BREAKER SIZES, WIRE SIZES, CONDUITS SIZES ARE FOR ZONING PURPOSES ONLY. IT IS THE RESPONSIBILITY TO OF THE ELECTRICAL CONTRACTOR TO CONFIRM COMPLIANCE WITH LOCAL ELECTRICAL CODES AND PASS ALL APPLICABLE AND NECESSARY INSPECTIONS, IN SOME EVENTS, IT MAY BE NECESSARY TO PERFORM AN ELECTRICAL LOAD STUDY TO VERIFY THE CAPACITY OF THE EXISTING SERVICE THIS IS NOT THE RESPONSIBILITY OF CONCORDIA. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 2. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE APPROVAL 3 CONTRACTOR SHALL FIELD LOCATE ALL BELOW GRADE GROUND LINES AND UTILITY COMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCH LINES PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR RELOCATION OF MATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB -FRAME FOR PLATFORM, 26 WHEN THE PROJECT SCOPE REQUIRES THE USE OF THE SAFETY CLIMB, THE GENERAL ALL UTILITIES AND GROUND LINES THAT MAY BECOME DISTURBED OR CONFLICTING IN ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES, CONTRACTOR SHALL ENSURE THE SAFETY CLIMB IS FREE OF OBSTRUCTIONS, NOT THE COURSE OF CONSTRUCTION. COPPER -CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND RUBBING ON OR TRAPPED BY ANY INSTALLED CUSTOMER EQUIPMENT, IS VISUALLY DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER, TAUT, MEETS MANUFACTURER INSTALLATION SPECIFICATIONS, AND IS FIRMLY SECURED CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS AND AT ALL CABLE GUIDE LOCATIONS UPON PROJECT COMPLETION. RUBBER MATTING, REPAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS, MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES AND ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO 29. COMPLETION OF PROJECT SHALL NOT OBSTRUCT, TRAP, LOOSEN, OR OTHERWISE THE DRAWINGS AND SPECIFICATIONS IT IS THE POSITION OF T-MOBILE TO APPLY FOR CAUSE FAILURE TO MEET MANUFACTURER INSTALLATION REQUIREMENTS FOR THE PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED SAFETY CLIMB. PERMITS. 30 CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITH 3. ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCAL ALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALL CODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTION NECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICES SPECIFICATIONS. SUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING, TRENCH BOXES/SLOPING, BARRIERS, ETC. 4. CONTRACTOR SHALL CONTACT LOCAL 611 FOR IDENTIFICATION OF UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION Al THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANY DAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS 5, CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED REPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THIS INSPECTIONS. CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HIS WORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS 6 ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND EXPENSE TO THE OWNER'S SATISFACTION. SITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALL DISCREPANCIES REPORTED TO THE ENGINEER 32 ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIP 7 DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. SHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANY WORK FOUND BY THE T-MOBILE REP TO BE OF INFERIOR QUALITY ANDIOR WORKMANSHIP SHALL BE REPLACED ANDIOR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS B. DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS OBTAINED. OTHERWISE NOTED. 33. IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF 9. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION MATERIALS LISTED HEREINAFTER BY MANUFACTURER'S NAMES ANDIOR SAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR MANUFACTURER'S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERS AS SPECIFIED. 10 CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED THESE ELEMENTS AREAS FOLLOWS: LATERAL BRACING, 34. T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED -UP AT THE T-MOBILE WAREHOUSE, ANCHOR BOLTS, ETC. NO LATER THAN 46HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTED AND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACE THE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BE 11 CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP. DRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK 35. T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANY 12. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR EQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILE CT DOCUMENTS, EITHER BEFORE AFTER INSTALLATION AND THE THE CONTRACTOR REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALL EQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THE REQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING. REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO T-MOBILE OR THEIR ARCHITECT/ENGINEER. 13. EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. SPECIAL CONSTRUCTION 14. CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS PROJECT TO MATCH EXISTING PRE -CONSTRUCTION CONDITIONS TO THE SATISFACTION ANTENNA INSTALLATION NOTES: OF THE T-MOBILE CONSTRUCTION MANAGER 15. ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURING INSTALLATION USING A SILICONE SEALANT 16. WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET, CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORD IMMEDIATELY- 17. CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE AND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. 16. CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF EACH DAY. 19. CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWER CORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY. 20. CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC) WITH A PDF MARKED UP AS -BUILT SET OF DRAWINGS UPON COMPLETION OF WORK. 1. WORK INCLUDED: A ANTENNA AND COAXIAL/HYBRID CABLES ARE FURNISHED BY T-MOBILE UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS. ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PERSONNEL. B INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND T-MOBILE SPECIFICATIONS. C INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS. D. INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE AND PROVIDE PRINTOUT OF THAT TEST. E. INSTALL COAXIALIHYBRID CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS WEATHERPROOF ALL CONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. TERMINATE ALL COAXIAUHYBRID CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED. 21. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDED SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALL 2. ANTENNA AND COAXIAL/HYBRID CABLE GROUNDING: ALL ITEMS PROVIDED. A ALL EXTERIOR #6 GREEN GROUND WIRE -DAISY CHAIM CONNECTIONS ARE TO BE ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESE CONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATC ENGINEERING IMMEDIATELY FOR CORRECTION OR RE -DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING OR ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. s 0.� AMERICAN TOWER• a ATC TOWER SERVICES LLC Li 1 FENTON MAIN 71 SUITE 300 4 CARY, NC 27511 0 PHONE: (919) 460-0112 a 4069-11 10 N THE USE AND PUBLICATION OF THESE DRAWINGS O SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR - DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER y IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE A0 ..fORCONSTRUCTION E0NA11I2012024 0 - 0 A A ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54643 SEAL: �•���5 C OI�S��,,�� SANTHOSHA �•c SHANBHOGUE E-49097 70 CARY w NC ,'le IN A1`1 `N'N" II Digitally Signed: 2024-11-20 T • .Mobile- ATC PROJ. #: 14907583_GO CUST. ID: HAYWARD WI-ATC 311256 CUST.M AlNO947A GENERALNOTES SHEET NUMBER: REVISION: G-002 0 SITE PLAN NOTES: 1 THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2. ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS. 3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. PROPOSED CABLE NOTES: 1. ESTIMATED LENGTH OF PROPOSED CABLE IS 300'. ESTIMATED LENGTH OF CABLE WAS PROVIDED BY CUSTOMER OR CALCULATED BY ADDING THE RAD CENTER AND THE DISTANCE FROM THE SHELTER ENTRY PLATE TO THE TOWER (ALONG THE ICE BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF 15% (OF THE TWO PREVIOUS VALUES), CDS DEFER TO GREATEST CABLE LENGTH. 2. ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE EXISTING CABLE SUPPORT STRUCTURES AS PROVIDED FOR CARRIER TO ADEQUATELY SECURE CABLES, USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP -INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. OTHERWISE, ATTACH CABLES TO HORIZONTAL OR DIAGONAL TOWER MEMBERS USING PROPOSED STAINLESS STEEL ADAPTERS (DO NOT ATTACH TO TOWER LEG). X------ --- X EXISTING (1) 1-5/8' NSN HIGH CAP HCS CABLE x (TO BE REMOVED) x EXISTING T—MOBILE METER AND SERVICE MAIN DISCONNECT )A4] T L P UT ` GRAVEL SURFACE x PROPOSED (1) 2.00- HYBRID TRUNK 6/24 4AWG 90M CABLE (SEE PROPOSED CABLE LENGTH NOTES ON THIS PAGE FOR LENGTH AND ROUTING GUIDELINES) I' SELF SUPPORT TOWER f k� r DETAILED SITE PLAN GRAPHIC SCALE Al 0 10 20 ( IN FEET) 1 UNIT = 20 FEET f SHELTER EXISTING T—MOBILE 8' X 8' PLATFORM/PLINTH 1 2 WITHIN A 10' X 12' GROUND SPACE so 10 (MODIFIED AS REQUIRED FOR UPGRADE FROM 67001-iRol TO 6790AH SR T 6X24 CONFIGURATION) GENERATOR FILL POINT f iS i 0 i A AMERlGAN TOWER' ATC TOWER SERVICES LLC c 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE OQ— FOR CONSTRUCTION EDNA1112012024 0. 0- ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 — SEAL: ION1j�� C ' rr= '• SANTHOSHA SHANBHOGUE E-49097 CARY o ..n N rrfr e I'OINIA'�j1�,',,,. Digitally Signed: 2024-11-20 T - -Mobile ATC PROJ. #: 14907683 GO COST. ID: HAYWARD WI-ATC 311256 COST. #: Al N0947A DETAILED SITE PLAN SHEET NUMBER: REVISION: C-101 0 I SITE PLAN NOTES: 1. CONTRACTOR TO VERIFY THERE IS NO LIVE AAV FIBER RUNNING THROUGH EXISTING DEAD EQUIPMENT. IF 80, THIS WILL NEED TO BE RERUN THROUGH CONDUIT PRIOR TO REMOVING DEAD 2G (6201 CABS) EQUIPMENT. 2. ALL OPEN PORTS NEED TO BE SEALED / WEATHERPROOFED PROPERLY 3. ALL UNNEEDED I EXCESS EQUIPMENT AND GARBAGE TO BE REMOVED FROM EQUIPMENT AREA. DISPOSE OF MATERIALS PROPERLY OFF SITE. EXISTING 10' X 12' LEASE AREA EXISTING COVP - (TO BE REMOVED) EXISTING H-FRAME - (TO BE REMOVED) - — - EXISTING ICE BRIDGE — — Y i- EXISTING - (1) 1-518" NSN HIGH CAP HCS CABLE (TO BE REMOVED) L EXISTING AMOB J (TO BE REMOVED) EXISTING MODULE STAND AND AMOB (TO BE REMOVED) EXISTING PPC EXISTING H-FRAME EXISTING I GPS ANTENNA I A � i EXISTING 8' X 8' PLATFORM J� EXISTING DELTA SSC — _ I (TO BE REMOVED) EXISTING (1) ASIA, (2) ABIA, AND (1) ABIL (TO BE RELOCATED) EXISTING (1) ASIK, (1) FSMF, AND (1) CSR 7705 SAR A (TO BE REMOVED) 1 EXISTING GROUND EQUIPMENT LAYOUT GRAPHIC SCALE 3 0 1.6 3 ■' (IN FEET) 1` 1 UNIT = 3 FEET T-MOBILE CM APPROVAL REQUIRED BEFORE INSTALLING CABINETS. EXISTING RELOCATED (1) ASIA, (2) ABIA, AND (1) ABIL EXISTING ICE BRIDGE PROPOSED (1) 2.00" HYBRID TRUNK 6/24 4AWG 90M CABLE (SEE PROPOSED CABLE LENGTH NOTES ON PAGE C-101 FOR LENGTH AND ROUTING GUIDELINES) 1 PF. t-[SU7 HPL3.05 600A DC CABINET (4) ABIL, (2) AMIA, AND (1) CSR IXRE V2 INSIDE PROPOSED HPL3.05 CABINET 2 PROPOSED GROUND EQUIPMENT LAYOUT GRAPHIC SCALE 3 0 1.5 3 N (IN FEET) 1 UNIT = 3 FEET EXISTING PPC I EXISTING H-FRAME EXISTING GPS ANTENNA EXISTING 8' X 8' PLATFORM EXISTING 10' X 12' LEASE AREA fA LB3 BATTERY CABINET -0 i i P i 0 AMERICAN TOWER' { ATC TOWER SERVICES LLC t 1 FENTON MAIN SUITE 300 CARY, INC 27511 PHONE: (919) 468-0112 4069-11 c r THE USE AND PUBLICATION OF THESE DRAWINGS 9 SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE 0o FOR CONSTRUCTION EDNA11l20/2024 0 Z\ 0 ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 SEAL: ONS�N t =, SANTHOSHA SHANBHOGUE E-49097 CARY W zz o :.n N S. r�VI, �OrA'IA ll Digitally Signed: 2024-11-20 T - -Mobile ATC PROJ. #: 14907583 GO COST. ID: HAYWARD WI-ATC 311256 COST. #: Al N0947A DETAILED EQUIPMENT PLAN SHEET NUMBER: REVISION: C-102 0 TOP OF EXISTING HOIEST APPURTENANCE RE TOP OF EXISTII ELE 2 1 / D ;�0 PROPO (1)1-5/8" NSN HIGH C) (TO PROPOSED (1) 2.00" HYB 4AWG 9 (SEE CABLE NI TOWER ELEVATION SCALE: N.T S PER MOUNT ANALYSIS COMPLETED BY TEP, DATED 10/29124, THE EXISTING MOUNT CAN ADEQUATELY SUPPORT THE PROPOSED LOADING. f r AMERICANTO VER• _ ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 F PHONE: (919) 468-0112 4069.11 c c THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV, DESCRIPTION BY DATE 0o FOR c%smUCTION _EDh j11512f112024 0 - - A L A ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 SEAL: ��IL1111111ff1J/jI, C 0 SANTHOSHA , SHANBHOGUE E-49097 -;o CARY NC 24' •rr4 r `o+N1A1`1,����,,. Digitally Signed: 2024-11-20 T - -Mobile ATC PROJ. #: 149D7583 GD COST. ID: HAYWARD WI-ATC 311256 COST.#: A1N0947A TOWER ELEVATION SHEET NUMBER: REVISION: C-201 0 EXISTING FF-65C—R1 ANTENNA (TO BE REMOVED) (1 PER SECTOR) (TYP. 3) EXISTING AHLOA RRU TO REMAIN (1 PER SECTOR) (TYP. 3) EXISTING TOWER EXISTING ASU9338TYPO1 COVP (TO BE REMOVED) (TYP. 1) 1 dad C2 A2 0 2 Q EXISTING TMBXX-6517—A2M ANTENNA (TO BE REMOVED) (1 PER SECTOR) (TYP. 3) Al EXISTING FXFC RRU (TO BE REMOVED) (TYP. 2) EXISTING SECTOR MOUNT (TYP.) R2 A GPROPOSED FFVV-65C-R2N23 ANTENNA (1 PER SECTOR) (TYP. 3) 2 PROPOSED AHFII RRU 50 (1 PER SECTOR) (TYP. 3) EXISTING AHLOA RRU TO REMAIN (1 PER SECTOR) (TYP. 3) EXISTING TOWER PER MOUNT ANALYSIS COMPLETED BY TEP, DATED 10129124, THE EXISTING MOUNT CAN ADEQUATELY SUPPORT THE PROPOSED LOADING. EXISTING SECTOR MOUNT (TYP.) 1 EXISTING ANTENNA PLAN N 2 FINAL ANTENNA PLAN SCALE: N T.S. SCALE: N.T.S. EXISTING ANTENNA SCHEDULE NOTES FINAL ANTENNA SCHEDULE LOCATION ANTENNASUMMARY NON ANTENNA SUMMARY 1. GC TO VERIFY THE FINAL RFDS LOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY MATCHES THE FINAL MECH/ELEC ADDITIONAL TOWER MECH/ELEC ADDITIONAL TOWER SECTOR RAID AZ POS ANTENNA BAND STATUS STATUS CONSTRUCTION DRAWINGS. SECTOR RAID AZ POS ANTENNA BAND STATUS STATUS D-TILT MOUNTED EQUIPMENT D-TILT MOUNTED EQUIPMENT GC TO NOTIFY ATC PM OF ANY _ Al TMBXX-6517—A2M L1900,U1goo 0%2' RMV (2) FXFC RMV DISCREPANCY PRIOR TO 14600,L700,1_600,1_21100, AHLOA RUN ALPHA 232' 0' INSTALLING THE EQUIPMENT. ALPHA 232' 0° Al FFVV-65C-R2N23 L1900,N1900,LAWS3, 0'/2',2' ADD AHFII ADD A2 FF-65C—R1 L700,N600,L600 0%2' RMV AHLOA RMN 2. GC TO CAP ALL UNUSED N2100 B 1 TMBXX-6517—A2M L 1900, U 1900 0' 2' RMV _ _ PORTS. N600,L700,L600,L2100, BETA 232' 120' % 3. GC TO CONFIRM SPACING OF BETA 232' 120° B1 FFVV-65C-R2N23 L1900,N1900,LAWS3, O'12',2' ADD AHLOA RMN B2 FF-65C—R1 L700,N600,L600 0%2- RMV AHLOA RMN PROPOSED EQUIP DOES NOT N2100 AHFII ADD CAUSE TOWER CONFLICTS — C 1 TMBXX-6517—A2M L 1900, U 1900 0%2' RMV — NOR IMPEDE TOWER CLIMBING N600.L700.L6D0,L2100, AHLOA RMN GAMMA 232 ' 240' GAMMA 232' 240° C7 FFW-65C R2N23 L1900,N1900,LAWS3, 0'12°,2' ADD C2 FF-65C—R1 L700,N600,L600 0%2' RMV AHLOA RMN PEGS. AHFII ADD STATUS ABBREVIATIONS N2100 RMV: TO BE REMOVED RMN: TO REMAIN REL: TO BE RELOCATED ADD: TO BE ADDED CABLE LENGTHS FOR JUMPERS JUNCTION BOX TO RRU: 15' RRU TO ANTENNA: 10' EXISTING FIBER DISTRIBUTION I OVP BOX EXISTING CABLING SUMMARY FINAL FIBER DISTRIBUTION I OVP BOX FINAL CABLING SUMMARY MODEL NUMBER STATUS CABLE CITY, SIZE, TYPE STATUS EQUIPMENT SCHEDULES MODEL NUMBER STATUS CABLE QTY, SIZE, TYPE STATUS (1) AS09338TYPO 1 RMV (1) 1-518" NSN HIGH CAP HCS RMV (1) 2.00" HYBRID TRUNK 6/24 4AWG 90M CABLE CABLE ADD I I i C f AMERICAN TOWER• ATC TOWER SERVICES LLC t 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE o FPSjtBTRUC710N EDNA11,2012024 A ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 SEAL: r� SANTHOSHA SHANBHOGUE — E-49097 CARY W NC: Digitally Signed: 2024-11-20 T • -Mobile-- ATC PROD. #: 14907583 G0 COST. ID: HAYWARD WI-ATC 311256 COST. #: Al NO947A ANTENNA INFORMATION & SCHEDULE SHEET NUMBER: REVISION: C-401 0 EXISTING/PROPOSED MOUNTS AND/OR MOUNT MODIFICATIONS NOT SHOWN FOR CLARITY. REFER TO ANTENNA PLANS, MOUNT ANALYSES AND/OR MOUNT MODIFICATION DOCUMENTS FOR ADDITIONAL DETAIL. EXISTING OR PROPOSED MOUNTING PIPE PROPOSED ANTENNA DOWNTILT BRACKET (PER MANUFACTURER) (INSTALL THIRD BRACKET IF REQUIRED) PROPOSED ANTENNA 1 PROPOSED ANTENNA MOUNTING DETAIL - TYPICAL SCALE: N.T.S. PROPOSED M12 BOLTS (TYP. 4) THROUGH PLATFORM PROPOSED CABINET EXISTING PLATFORM SING 3 CABINET ATTACHMENT TO PLATFORM SCALE: N.T.S. PROPOSED RRU (TYP.) (MOUNT PER MANUFACTURER'S SPECS) (ENSURE THAT BRACKET DOES NOT CONFLICT WITH EXISTING OR PROPOSED EQUIPMENT) PROPOSED RRU MOUNTING HARDWARE (INCLUDED WITH RRU) EXISTING OR PROPOSED MOUNTING PIPE &_ERO 0 ED RRU MOUNTING DETAIL - TYPICAL SCALE: N.T.S. e i e R AMERNCANTO VER• _ ATC TOWER SERVICES LLC r 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 c r THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV DESCRIPTION BY DATE /0 FOR CONSTRUCTION EDNA11/201202 n ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 SEAL: =��•` SANTHOSHA= SHANBHOGUE E-49097 r o CARY :.n NC Digitally Signed: 2024-11-20 T - -Mobfle ATC PROJ. #: 14907583_GO COST. ID: HAYWARD WI-ATC 311256 COST. #: Al N0947A CONSTRUCTION DETAILS SHEET NUMBER: REVISION: C-501 0 EXISTING ANTENNAS TO EXISTING ANTENNA MASTS EXISTING COAX GROUND KITS PROPOSED #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION TO PROPOSED RRU GROUND LUG (TYP.) GROUNDING CONNECTION TO EXISTING TMAs EXISTING GROUNDING I CONNECTION TO LIGHTNING PROTECTION SYSTEM j NOTES: I PROPOSED ANTENNA PROPOSEDJUMPER PROPOSED CONNECTOR AND WEATHERPROOFING KIT PROPOSED WEATHERPROOFING KIT — PROPOSED CABLE 2 GROUND KIT �0 ANTENNA CABLE TO CABINET (TYP.) #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION GROUND BAR MOUNTED0,33 NEARIBELOW ANTENNA (TO BE INSTALLED IF REQUIRED) 1. THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHT ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THE CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THE CONSTRUCTION MANAGER OF ANY CONFLICTS. 2. SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATEST EDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN. TYPICAL ANTENNA GROUNDING DIAGRAM SCALE: N.T.S. CONDUIT USE CASE TYPE RAC (METALLIC) AC, DC COMM PVC AC POWER LFMC AC, DC, COMM EMT INDOOR AC, DC COMM LFNC GROUND WIRE STANDARD CONDUIT USE TABLE TO ANTENNA i TO EQUIPMENT ANTENNA CABLE 2 1/2"0 MAX GROUNDING KIT PER CABLE MANUFACTURER'S RECOMMENDATIONS (ANDREW OR APPROVED EQUAL) #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) TO GROUND BAR GROUND KIT NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PART NUMBER 221213) AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS 0 CABLE GROUND KIT CONNECTION DETAIL SCALE: N.T.S. LOCATION USE CASE EXAMPLE ABOVE GROUND ABOVE GROUND PPC TO SSC UNDERGROUND PPC TO SSC OR BACKHAUL UNDERGROUND TRANSPORT HUB TO SSC MAX 6' PER CONDUIT RUN, TIGHT LOCATIONS BETWEEN HUB AND CONDUIT BUT NOT ABOVE GROUND ONLY TO BE USED WHERE IT CAN BE STEPPED ON INDOOR NOT EXPOSED TO THE OUTDOOR CIRCUIT PANEL TO JUNCTION BOX ENVIRONMENT (MUST BE DRY) CONCEALING AND PROTECTING BTCW RISERS GROUND RING TO MGB OR SSC ONLY EXCEPTION CONDUIT USE TABLE CONDUIT USE CASE LOCATION USE CASE EXAMPLE TYPE EMT OUTDOOR DC, (NOT PREFERRED) COMM RMC OUTDOOR/INDOOR NONMETALLIC PER NEC (ALUMINUM) GUIDLINES OUTDOOR WHEN USED WITH WATERTIGHT HUBS ONLY ABOVE GROUND BETWEEN EQUIPMENT AND BATTERY CABINET OR EQUIPMENT TO EQUIPMENT CABINETS FOR INTER CABINET CONNECTION MAT BE USED AS A LOWER COST ALTERNATIVE TO METALLIC RMC, MUST MEET OR EXCEED FEDERAL SPEC: WW-C-540C, UL-6A, ANSI C80.5, NEC 344.10 (A) ALLOWS THE USE OF EITHER ALUMINUM OR GALVANIZED FITTINGS 4 CONDUIT USE TABLES PROPOSED CABINET #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR it EXISTING EQUIPMENT GROUND BAR (TYP.) 5 CABINET GROUNDING DETAIL SCALE: N.T.S. 3/8" X 1-1/2" SS BOLT 3/8" SS LOCK WASHER (EACH SIDE) (EACH SIDE) i / gAofj ri 1/4" X 4" X 6" GROUND BAR (ERICO PIN: EGBA14406CC OR EQUAL) TWO -HOLE LUG, TO BE USED WITH #2 AWG BCW (LOWER TOWER GROUND BAR ONLY) GROUND BAR NOTES: 1. GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS, WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). 2. GROUND BAR TO BE BONDED DIRECTLY TO TOWER. 3 TOWER GROUND BAR DETAIL SCALE: N.T.S. ELECTRICAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. 2. ATC HAS NOT VERIFIED ANY EXISTING T-MOBILE GROUND EQUIPMENT OR ELECTRICAL LOADING. PROPOSED WORK BASED ON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE. CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HAS SUFFICIENT SPACE FOR PROPOSED BREAKER. PROPOSED CABLE AND CONDUIT SHALL BE MINIMUM SIZE PER BELOW IN CHART. 3. FOR SPECIFIC CABINET ANCILLARY EQUIPMENT WIRING REQUIREMENTS, THE T-MOBILE CONTRACTOR SHOULD REFERENCE DESIGN DOCUMENTS PROVIDED BY T-MOBILE FOR THIS CURRENT PROJECT CONFIGURATION, IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS & NEC STANDARDS & PRACTICES. VOLTS OCPD SIZE WIRE SIZE GROUND CONDUIT 1201240V OR 1201208V BOAI2P 343AWG #8AWG 1-1/4" 100/2P 3412AWG 98AWG 1-1/4" 125AI2P 341310 AWG #6 AWG 2" 150Al2P 34M AWG #6 AWG 2" 200A/2P 3413/OAWG #6 AWG 2" 240V OR 200V BOA/2P 243 AWG #8 AWG 1-114" 10012P 242AWG #8AWG 1-1/4" 125A/2P 241= AWG #6 AWG 2" 2" — 150AI2P 2413/0 AWG #6 AWG 200A/2P 2413/OAWG #6 AWG 2" � ELECTRICAL NOTES U m a a AMERICANTO VER' a ATC TOWER SERVICES LLC 0 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 ¢ 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR �= WHICH THEY ARE PREPARED. ANY USE OR w DISCLOSURE OTHER THAN THAT WHICH RELATES n TO AMERICAN TOWER OR THE SPECIFIED CARRIER I j IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. IREV. DESCRIPTION BY DATE 0O FORCONSTRUCTION EDNAIV2(!@024 0 ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12454 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 SEAL: j11►111111I11//11j1 O �J I ,,•f �,rff��i SANTHOSHA SHANBHOGUE E-49097 c CARY W NC =�= .�. Digitally Signed: 2024-11-20 T • .Mobile-" ATC PROJ. #: 14907583 GO OUST. ID: HAYWARD WI-ATC 311256 OUST.M AlN0947A GROUNDING DETAILS SHEET NUMBER: REVISION: E-501 0 PANEL TYPE LIGHTING 8 APPLIANCE SYSTEM 12024OV, 10, 3W, 24 CKT LOCATION: TENANT EQUFW_NT LEASE AREA DESIGNATION: TENANT PANEL MOUNTING: SURFACE MAIN BREAKER (MB): 200A ENCLOSURE: NEMA 3R MAIN BUS RATING: 200A PANEL NOTES: EXISTING MN AAC. RATING: WA CONNECTED FEEDER OR BRANCH CIRCUIT FEEDER OR BRANCH CIRCUIT CONNECTED LOAD(kVA) BRIEF DESCRIPTION BRIEF DESCRIPTION LCAD(WA) BREAKER CIRCUIT POLE NO .. ". ROLE NO. CIRCUIT BREAKER A B AMPS ROLES WIRE GND COND. COND. GND WARE I POLES I A A I B 0.01 1 3 2 1 15 L 0.50 SURGE PROTECTOR 20 2 3 3 4 1 ZO 0.18 001 3 12.75 DATA HPL3 200 2 34310 #8 2" 7 8 8 O.TXi 12.75 MOD 0.18 HPL3 GR 20 1 2412 #12 9 4 10 0.00 5.25 O.fA.. 525 HPL3EXPANSION 100 2 34M #8 2" 13 4 14 O.OD 0.00 15 i B 000 0.00 17 18 0.00 0.00 19 20 000 ODD 21 22 O.OD 0.00 23 24 0.00 18.2 18.0 A B TOTAL 0.5 0.2 18.7 182 38.9 CONNEDIEDLOAD (WA) 18.7 18-2 36.9 DEMANDLOAD(k1/A) DERAT/NGFACTOR(80%) CIRCUIT NOS DEMANDLOAD SIZING: 192 AMPS 1) PANEL SCHEDULE EASED ON INFO PROV IDED TO AE; IF PA NEL HAS DIFFERENT EXLSRNG LQA DS THAN SHONM, STOP NARK AND CONTACT FOR 2) EXISTING CIRCUIT, UNKNOWN LOAD, MAX DEMAND ASSUMED FOR LOAD CAPACITY ASSESSMENT. 3) EXISTING CIRCUIT, KNOWN! LOAD FOR LOAD CAPACITY ASSESSMENT 4) PROPOSEDGRCUIT, KNOWN LOAD FOR LOAD CAPACrYASSESSMENT 5) EXISTING CIRCUIT DEMUD. 6) EXISTINGGRCUITDEMt7D. BREAKER REPLACED AS SHOWN AND CIRCUIT AS PROPOSED, KI4CWN LOAD FOR LOAD CAPACITY ASSESSMENT ELECTRICAL NOTES: 1. THIS DIAGRAM REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. 3. ATC HAS NOT YET VERIFIED ANY EXISTING T-MOBILE GROUND EQUIPMENT OR ELECTRICAL LOADING. PROPOSED WORK BASED ON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE. CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HAS SUFFICIENT SPACE FOR PROPOSED BREAKER. 1 PANEL SCHEDULE EXISTING PANEL PROPOSED BREAKER (SEE PANEL SCHEDULE) I z L — PROPOSED DELTA HPL3.05 CABINET (INSTALLED AND CONNECTED AS DIRECTED BY T-MOBILE) PROPOSED DELTA BATTERY CABINET (INSTALLED AND CONNECTED AS DIRECTED BY T—MOBILE) EXISTING T—MOBILE PLATFORM i EXISTING GRADE TERMINATE PER MANUFACTURER'S PROPOSED POWER CIRCUIT SPECIFICATIONS (SEE PANEL SCHEDULE) ELECTRICAL SCHEMATIC T C SCALE: N.T.S. IK S i i AMERICAN TOWER' ATC TOWER SERVICES LLC c 1 FENTON MAIN SUITE 300 CARY, INC 27511 F PHONE: (919) 468-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE 00 FORCQU$MUCTION EDNA11120/2024 / 1 n n ATC SITE NUMBER: 311256 ATC SITE NAME: HARD ROCK WI T-MOBILE SITE NAME: HAYWARD WI-ATC 311256 SITE ADDRESS: 12464 NORTH STATE HIGHWAY 27 HAYWARD, WI 54843 SEAL: 'lAllll44S111111►LLI, Ci 0 Ns I oNA ``�,, ►If 1111111ri1 Digitally Signed: 2024-11-20 P •-Mobilew ATC PROJ. #: 14907583_GO COST. ID: HAYWARD WI-ATC 311256 COST. #: Al NO947A PANEL SCHEDULE & ELECTRICAL SCHEMATIC SHEET NUMBER: REVISION: E-601 0 Proposed RAN Equipment Template: 679UAH_SR T 6x24 Emlimum 1 2 3 Emloeure Typo Tb+nar Tbp ilileunl olalla} Dalta HPU.115 =A Sit! SUpport C2111" 1 `Delia L03 Saftery CaR►Mre1(4 alb FLMO AHMI Nix AHLoi 031 H 19M MsaQ j rtz+aQ �►iatx� } Mj L1 01110 cs1aQ li 11h"3413ARR1, Beadbend 'ASIA ' ASILtYxt I L600 "600 1 L7LKi H19M j 1 L1200 tM (DARK) L2100 t.Awaa �ARK1 Suomond sutimodule M1Aazl MlLl3rl' 4 f Li00 119w y k60Q 1 L702 L2100 11!l11.1a 71 t13 W&RKI N191lri h "WrFds- intemal A-mabi la.oDmrdatasheeUFintoutl2a6be4df-9053-4083-b3B74MAwtQc5cF7+72bc3f2"7da-4ab4-acfit-74C*038bf5Q9 1014124. 10:2Q AM IUM00IDARK 15"aband 3tWfS f Trumport System Hyblld Cable system RAN Scope or wort: InX3=4S1[ PRFDSCreaQed A1ND947A Capadly-L1Q00 3_"irninary_?024-1D-04 AUitNls7tF CAR 6R§ % 2 (fdantj� ' FIYdr1n Trtri1 & 4 40MG � CABINET CONFIGURATION a112 I Configuration 6790A H—SR, * For 5G and LTE Airscale BB dimensioning refer to Fiber Port matrices. (Alpha, Beta & Gamma) LB, M FDD - Lowband hNf as Anti;nnlpnro B12 (1.700) - 5 MHz w B71 000) -10 MHz Lu B71 (N600)-15 MHz FDD- Midband B4JB66 (1-2100) - 20 MHz B66 (N2100) - 20MHz B2 (L1900) - 20 MHz B25 (L1900) - 20 MHz g 5 3 z B25 (611900) - 20MHz SO Akwale TOD - Band 41 N41(2.5GHz) - 100MHz AHLOA AHFII +80MHz 700+600 AWs+PCs --—--— Ground 6/24 RPrPr to voltage booster wWk, for boost HrbrMTrunkl requirements per radio type and trunk b length SRAM LTE LTE FDD/TDD .7 L Alrscalel ANTENNA CONFIGURATION NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. z n L lA n C Q rs 0 u SUPPLEMENTAL SHEET NUMBER: REVISION: R-601 0 MANUFACTURER. DELTA MODEL HPL3.05 (HP -LARGE POWER CABINET) DIMENSIONS: ; 72' x SO' x 34.6" (H x W x D) WDGHT: 860 LBS NO EUUIPMEN7 NOTE: • CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUTS. DO NOT DRILL THROUGH KNOCKOUTS • CONDUIT MUST BE PROPERLY SECURED TO PREVENT DAMAGE TO CABINETS AND OR CABUNG W= PAIDL F01 OUf f �,ilu•ona�Rr_ •EMI �� I w e HE 00 PUNCH TNREE 24' HIM FOR HW TERUMT1DN . cpau LOWER E{' 2.2" 43.1" 6.3" PL✓AIIH LEFT VIEW GROUNDING NOTE: "CABINET GROUNDING TO USE A SINGLE, /2 B11CW CONDUCTOR, W/ 2—HOLE, 1" C—C. LONG BARREL, WINDOW LUG, IN 3/4" LTTIC TO GROUND RING. PLINTH GROUNDING IS NOT REQUIRED." 2' KNOCNOUi FOR FM Dr LL UM FOR OPS GNU r KN00I= FOR MW FOR F ofPPCRE I" KNOCKOM AKID= PDIER/CfHff FET FOR AOM Dr AAY/C.. DC POWER TNO HOLE LUO FOR OWUNDNO (B07F1 811E8) PLAN VIEW FRONT VIEW BOLT DOWN PATTERN &M348L671- HPL3.05 DELTA SITE SUPPORT CABINET SCALE: N.T.S. r 10100H= w rom ODIDIRf CONDUIT OW 9Afli7(Y OAa.E CONDUIT MUST K PROPEIpY TO PREVWM DAMW �I e tV 5 rrFo NOLE UN FOR all"mom om W% Cmov LOWER 6• " R i r ��•�T� y a 4� RIGHT VIEW MU CAEMET 000W MUST BE PROPERLY SE7CURED 70 PREMIM DAMAOE r MIXIMM FOR AC FOWi1! M BATrM CABN f 00lDUIT MUSE EIE P fR Y SE]L't = TO Pwma I (2) r IOIOCIDUfS w/ RK0 0010 f. LB CONDUIT BODY FOR 3/O T}iEV WME TIDlOUON THE (2) 1/2" . CONWT MUST DE PROF' MY $11111 D To Pffw.Nr DAmA" NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. mm SUPPLEMENTAL SHEET NUMBER: REVISION R-602 0 DO POMIF!! CNNN 0"m N mm— Fes! QA ('SR M11► N YEUA" E7HEFMET 01IB1Ei (SHINN N KM - CABLE CABLE MANAGEMENT/BLANK CABLE MANAGEMENT/BLANK 1141 CABLE MANAGEMENT/BLANK + OPTIONAL EQUIPMENT 1J RACK MOUNT SPD SHELF (IF NEEDED) WED FOR HYBRID TERMINA FSEE ON FMAB INTERNAL ROUTING (DOOR OPEN) RU SLOTS RACK ASSIGNMENTS BREAKER SHELF RECTIFIER SHELF SHELF 1 DELTA VOLTAGE BOOSTER f1 -2RU 2 3 DELTA VOLTAGE BOOSTER 02 - 2 RU 4 5 CABLE MANAGEMENT 6 AIRSCALE # I 7 S 9 CABLE MANAGEMENT 10 AIRSCALE #2 11 12 13 CABLE MANAGEMENT 14 LEGACY BASEBAND 15 16 17 CABLE MANAGEMENT 18 OPTIONAL EQUIPMENT 19 20 21 FIBER TRAY #2 22 FIBER TRAY #1 23 RACK MOUNT SPD SHELF (IF NEEDED) 24 25 UNUSED/RESERVED 26 FSEE ON FMBA 27 FLOOR SPD SHELF 34867 - HPL3.05 DELTA SITE SUPPORT CABINET 1T SCALE: N.T S DELTA d rl �frJrS FRONT VIEW (DOOR OPEN) NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SUPPLEMENTAL SHEET NUMBER: REVISION R-603 0 DC MANUAL EEIEIII 2% 1P 0 LOAD BWPX s 1Cit 1P A aft100 I xJ RE�YE 3 P00=10 FOR 4tlGa 9P meEXID AL CAB111=R lu EXIER7IAL SKilER1f lm DC POWER SYSTEM r liiJ OW BREWER30A gym. 1P 0 o � A �'f • AL CRY CONV= CoNnwL ER x� RE1rIfOE 300 aE�uEs) � ■12 ? (oPR 20M RWW e00VER IIIIIII CS Slot 1 2S 49 5 6 7 9 9 10 11131 19 20 71122 23124 25 26 27 29 29 30 31 3u2 3�3 4 35 t 1 � A 7ii'7 S $$ N N N N p 1 3 a N b b a 2 c c a u o E a n a a cai .cp .L a C CBSIot 1 , 1 3 111516171 81 9 1101 11 12 13 ld 15 16 17 19 19 20 21 21 23 24 25 26 27 18 29 3D 91 32 33 s s s a s s a a a a a TL 0 34867 - HPL3.05 DELTA SITE SUPPORT CABINET SCALE: N.T.S. NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SUPPLEMENTAL SHEET NUMBER: REMSION: R-604 0 NOTE: 1. ALL CONDUIT AND FITTING ENTRANCES INTO CABINETS AND ENCLOSURES MUST UTILIZE MYERS OR EQUIVALENT HUBS OR SEALING WASHERS TO PREVENT WATER ENTRY/SEEPAGE INTO CABINETS AND ENCLOSURES. 2. (LIQUIDFLEX) FLEXIBLE METALLIC CONDUIT (LFMC) & ASSOCIATED FITTINGS CAN BE USED AS NEEDED BUT ONLY FOR TIGHT CONDUIT BENDS AND RUNS SUBJECT TO UL AND NEC LIMITATIONS. 6' MAX PER CONDUIT RUN. 3. POWER CONDUIT BODY ATTACHED WITH SHORT NIPPLE AND SEALING WASHER INSIDE & OUT. (FOR DOOR HOOD CLEARANCE) 4. PULLING ELBOWS MAY BE USED IN LIEU OF A CONDUIT BODIES WHEN CLEARANCE IS LIMITED. 5. (DO NOT USE CHASE NIPPLES) CONDUIT SHOULD HAVE SEALING WASHERS INSIDE AND OUT w/ LOCK NUT AND CAP. 3' KNOCKOUT w RIGID CONGUiT. CONDUIT BODY FOR BATTERY CABLE CONDUIT MUST BE PROPERLY SECURED TO PREVENT DAMAGE (3) 2' KNDCKOUT5 FOR DC AND ETHERNET CONNECTION TO BATTERY CABINET CONDUIT MUST BE PROPERLY SECURED TO PREVENT DAMAGE BACK PANEL FOLDS OUT 2' KNOCKOUT FOR FIBER 6 'O � o OPS 2' U. USED FOR CPS CABLE 2' KNOCKOUTS FOR AC POWER TO DC CABINET FOR HEATER CONDUIT O U O MUST PREVEBE Y SECURED TO DAMAGE O4 O) 2' KNOCKOUT FOR Mw 1I 00ODELTA O I NI.3.05 DELTA LB3 0 FUT SITE 5 PPORT BATTERY O IIICAB F--f CABINET PUNCH THREE 2.5' HOLES FOR 2' (2) 3' KNOCKOUTS w/ ROD HYBRID TERMINATION I CONDUIT, LB CONDUIT BODY FOR O 3/0 THHN PARE THROUGH THE (2) 1/2' CONDUIT MUST BE 0 PROPERLY SECURED TO PREVENT (3) 1- KNOOMMIRTENDED DAMAGE 0 RA FOR PCALARMING. FIBER/ETHERNET FOR ARV 3 AAV/CIENA DC POWER - I CABINET LOWER 6' AUNTH �, •- �^ —0 - T5 - - i 75 75 'tia' ^ �.. CABINET LOWER 6' PUNCH TWO HOLE LUG FOR GROUNDING (BOTH SIDES) TWO HOLE LUG FOR GROUNDING (BORN SIDES) 1 34867 - HPL3.05 DELTA SITE SUPPORT CABINET SCALE: N.T.S. NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SUPPLEMENTAL SHEET NUMBER: REVISION: R-605 0 W 70 MANUFAC UFIM. I DELTA MODE L63 BATTERY TERY SUPPORT CABINET per: 720 x x 35' ----(H IM x D) WEKW- wo LOS OWMIT EOUFN NOTE: CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUM DO NOT DRILL THROUGH KNOCKOUTS • OONDUR MUST BE PROPERLY SECURED TO PREVENT DAMAGE TO CABINETS AND OR CANJNG WD CONOW, LL M17ERY owu 10PE1lLY Sf1 &M 3 FOR AO 3 OMR#ET FOR LEFT VIEW GROUNDING NOTE: "CABINET GROUNDING TO USE A SGIGLE, /2 BTCW CONDUCTOR, W/ 2-HOLE, V C-C, LONG BARREL WINDOW LUG, IN 3/4" LFNC TO GROUND RING. PLINTH GROUNDING IS NOT REQUMO." PLAN VIEW FRONT VIEW BOLT DOWN PATTERN DELTA LB3 BATTERY CABINET SPECIFICATIONS SCALE: N.T.S. Two HOLE UJO M owa Dan, aww I'M r I /• RIGHT VIEW NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. a a_ v a v N B rn T A SUPPLEMENTAL SHEET NUMBER: REVISIORL R-606 0 MANUFACTURER3 NOKIA MODEL: ASIL CONTROLLER CARD (474767A) DIMENSIONS: 1 9' X 8.62' X 14.84' WEIGHT: 6.8 LBS MANUFACTURER: NOKIA MODEL: ABIA WEIGHT: 4.6 LBS DIMENSIONS: 8.BW 4.2X1-1' 0 RF7T2 RF3 RF4 RF5 RF6 EAC (HDMI) SIN (HDMI) GROUND (DUAL -HOLE SOUT (HDMI) RESET 2x M5) LMPIEIF9 OOOOtl p0 0000 00 00 00 0❑ 00 00 00 ❑ ---A an — apI • Mr, FT AlI aka EIF2 (SFP) .J EIF3 (SFP) L 5[nVILE SEI2 (OSFP) SEI1 (OSFP) � ASIL DETAIL SCALE: N.T.S. MANUFACTURER: NOKIA MODEL' 3HE15548M DIMENSIONS: 17.25" x 10 x 1.75" WEIGHT: 10.5 LBS TFULLY EQUIPPED) WITHIN AMIA RACK __ 2 ABIA DETAIL SCALE: N.T.S GNSS RECEIVER MANAGEMENT SFP28/SFP¢ SFP/SFP+ 10 Gbps 25Gbps PORTS DC PSU DC PSU PORTS 1-24 25-32 -- - FRONT VIEW QSFP28 100GBPS GROUNDING CHASSIS. USE TWO PORTS 33-34 HOLE LUG. DESIGNED FOR #8 USB AWG BURNDY (YMSC2TC1045) CONSOLE NOKIA PIN# 52-1178-01 o CD Ta v REAR VIEW C7 O �cD o ° o 17.25" 10" SIDE VIEW 1.75" 34097 — NOKIA 7250 IXR—e ROUTER wl GNSS J SCALE: N.T.S. MANUFACTURER: NOKIA MODEL: ABIL WEIGHT: 4.4 LBS DIMENSf ONS: 6.6'X14,21X1.1 SFP28 S-RF1 S-RF2 r 8388 ra1HS 8 lUffliff 88 8 8 S-RF1 S-RF2 QSFP28 aABIL DETAIL_ SCALE: N.T.S. MANUFACTURER: NOKIA MODEL: AMIA WEIGHT: 112 LBS (UNIT ONLY) DIMENSIONS: 5.1'X15.7X77.6' l� AMIA DETAIL SCALE: N T S. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. '3 U U SUPPLEMENTAL SHEET NUMBER: REVISION R-607 0 �.: E - �01d_ '121• x wM ■. R nool+lt iQsae< OF _ �1'0)NA i1Cl011010 141! �AIlIf� t4.1f -IR} ! �R•��1 L�14 _�1� - Pa�AUL�N 2 �r FIBER _7 � RFS 6x24 W. I-z74• �? 3z 4a' 37.91• aw CON ECFORS (>!110 ! 43-10 FF31ILEj l t.16' ro I r 1 39179 - COMMSCOPE FFW-65C-R2N23 SCALE: N.T.S. imomce_ Ram- _ iE a•7�'i' �1 a � M _ - 7CIm ■ 3a.74• SACK V2L@ll ►EN ta.4aGROUND OC L71' - POPNER ALRH p NET 8-M 3 x 0P90 po= CPIs ob WOR-25 FOR Obp• MIT 7) O ncAL PORT! 2 34577 - AHFII - 4T4R DUAL -BAND RADIO SCALE: N.T.S FILLER PA9A%IETER VALLIF NOMINAL OIAMETTR INCH - C,'ROSti-SECT)ON AREA SgUAJtf INCHES 2. ya JACKET COLOR BLACK. WEIGHT UNFAIR FOOT PDDNL)5 2.65 ya NETWORK WIRELESS - SOLUTIONS 6x24 PARAMETER VRLUE 140)AINAL DIAMETER INCHE: 1.76 CR03:-5EnCN AREA Sd)1ARE INCHES 7-43 ,IACKET C(7LOii HULS,K 1VQGHT L FAR FOOT POI1NL)$ 2.n _ CQMMSCOPE 6x24 I STIFFENER TUBS - - (6x24) HYBRN TRUNK CROSS SECMN q wnl v•ru......_.�•o• pS' x 11"JCRIt H.i.1. j II". 17"!!%oI.i B�T.1. I PARAMETER VALUE NOMINAL DIAMETER INCHES I.B CROSS-SECTION AREA SQUARE INCHES) 2.54 JACKET COLOR BLACK WEIGHT LINEAR FOOT (POUNDS)_ 2-48 SINGLE MOJE X46 --- 4 AWG COPPER CONDUCTOR X12 RIP COlin ALLIANCE 6x24 - FLAME RESISTANT FILLERS CORRUGATED COPPER ARMOR PVC, OUTER JACKET PARAMETFIR VALUE NO1dIN.AL DIIMAE[ER INCHES 1.E2 L-.NO:iS-fiECpCN AREA SQENE IIJ CH ES 2.04 JACKET COLOR BLACK WE10NT LINEAR mo POUNDS P.39 RIP CORD PVC OUTER JACKET Qo _�- ff �1 Hu13ER+SUNDER 6x2-4 (6x24) HYBRID TRUNK CR65S SECTION a.s" • II" 5cAu N.T.s. 111" • 17" scALE H.T.S. y CrbN Vrndar C■bb Typr NomlrW 00 fin.) C.S. ArAr faq. In.) Wright Ib+Jft) -Tep Bnrhrut MAX ENTITLEMENT HCS 2,0 6 AWG 26• to 72A' a+6tr 1- thx HOB I+rndaas MiAx1 ar 4 Ill-nd.x In. AWAn 6x746AWG 1.46 td7 Lbl L6.3619.30 x 5.19(g1i1157157 NomkW DD 00 1.S9 Cxm oAWO L55 1.89 1-71 Sp3Tn SpkJ+5, S2 JIn 23S.77 C.y.Rnx f / 1.89 iMVS 604 6AWG 11.48 11,72 1.61 16.95 r =AD x 3.21 pJh, 16259) WeI ht (Ibn.7ft 171 Am h9M &aq,)AWG 11.46 167 1-65 1937 x IA03 x 5A2(sgAn 20970) Pind+m A 71n 231AP 4 AWO 250• t0 41T0' chbN Ieh90N ql Arre 4A14G lB :L54 2.qB 1a36 x 9.30 x 5 79 (wJi1152.15] NOmkW Lx7 n LB Gmm3cane 4A9)0 7.70 2.43 2.4 t►.J7 xiD.B3 x5.12 wlin 2JSA7 CS. AI- 1=� 2Si pmf. 6,94 4AWG 1.79 :2.52 2.65 LS.9Sx10.20x3.21(w11n142.69)WAlpht(IbAlft) 2,65 Amaherol LX244010 1.01 2.3 lzl3s L9.37x10.83 x 5.12(mJIn 209") pandsl6(rgfIr4 2151D7 3.24 6x14 C.*91v Bta Lkoot • OD n ILugth Vn J Allmr 6.2414AWG 19 1L54 J2.411 MI19.45 Ox Ama 7.60) NomkW OD On.) 2 Lb„ zn 4AWt1 176 24A a.24 2LN 19.h1 ew Amr 5.64 C.B AI.r lin 3.13 Has l4AWG i62 2-0A 7.d9 3R7 A 9.36 La- Ara 51.41 N/+l ht Ob4.lft) 3Ad l NWs W244AW0 1.77 Z61 2.65 29► r&B2[c s. Ala 7.D2) C+nMar(rgllol 1L40 C,. 16.244AWG 3 312 :2.56 2JRv P. P2 ,4. Am d.Sl (6x24) HYBRID TRUNK ENTITLEMENT INFORMATION I 1 8.5" x 11- SCALE N.73. 1 11- x 17- SCALE N.T.S. 13 3 HYBRID TRUNK INFORMATION 6X24 SCALE: N.T S NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SUPPLEMENTAL SHEET NUMBER: REVISION R-608 0 AM ERICArklill T10WER4 C O^ P O R A T I O N This report was prepared for American Tower Corporation by rn P Antenna Mount Analysis Report Mount Type ATC Site Name ATC Site Number Engineering Number Mount Elevation Carrier Carrier Site Name Carrier Site Number Site Location County Date Max Usage Result Prepared By: Jordan Marks TEP No.45988.1015373 7 ft Sector Hard Rock WI : 311256 14907583_C8_01 : 232 ft T-Mobile Hayward WI-ATC 311256 AlN0947A 12454 North State Highway 27 Hayward, WI 54843-7319 46.0835,-91.5133 Sawyer October 29, 2024 60% Pass Reviewed By: s 11111,a ` CON Imo.. Jo tr . Ey t 45T37-4� �y RALEIGH : W, INC ''aP NA1- 10/29/2024 WI COA # 4031-11 TEP- 326 Tryon Road - Raleigh, NC 27603 - 919.661.6351 Office - 919.661.6350 Fax - w .tepgroup.net iEPko7omllY o7mmvanbllrnnxdtoprodde di))4renl strvkes In dlffertnl /urhdktbm Depnxfirp on the/urbdktbryP �rlfbrial enpinrtNne and brad wneylnP terNtesarc povided ay EEP OpColl�a Drlonvre IirMlyd Ib611itY comParry, TEP frpineerbp, PLL� o North CaraA'no qo/esNwal amRM IbMEtY L�^P^^Y• ^� �R Enpineerinp, PLL[ o Nrw YorF pofesfforwl fimllM hahPrtY rorMonY6rrirra'ro^Iro[fw wMm are aroed,dbYTEPDa 0pCo L(r a DO— Ignited bobffiry eomyany. We acqube the rrgWsllr Iheraes in each Nate. AddMmat In1—Hon mn be obtapred fn— the comWy 0 MOUNT ANALYSIS JI.4 �] Eng. Number 14907583 C8 01 �October 29, 2024 Page 1 Introduction The purpose of this report is to summarize results of the antenna mount analysis performed for [carrier] at 232 ft. Supporting Documents 1 Spec. Sheet RFDS Photos Analysis Spec Sheet for ALT Fabrications 211611-7, dated May 18, 2018 RFDS Site ID: A1N0947A, dated October 4, 2024 Site photos from 2023 This antenna mount was analyzed using RISA-31) v22 analysis software. Basic Wind 5 107 mph (3-Second Gust) Bask wind Speed w/ Ice: 50 mph (3-Second Gust) with 1.50-inch radial Ice thickness Codes: ANSI/TIA-222-H/ IBC 2018 Risk category: H Exposure Category: B Topographic Procedure: Method 2 Topographic Feature: Flat Crest Height: 0 ft Crest Length: 0 ft Ss = 0.041, S1= 0.017 w D—Default Lm = 500 Ibsa, Lv = 250 Ibs• Spectral Response: Site pass: Live Loads: -uve toga{sj reaucrlan is Conlirmert to nulm not govern or not a! appPmaine Conclusion Based on the analysis results, the antenna mount meets the requirements per the applicable codes listed above. The mount can support the equipment as described in this report. If you have any questions or require additional information, please reach out to your American Tower contact. If you do not have an American Tower contact and have an Engineering question, please contact MountAnalysis@americantower.com. Please include the American Tower site name, site number, and engineering number in the subject line for any questions. TEP-326Tryon Road -Raleigh, NC27603-919661.63530ffice 919661.6350Fax - viww.tepgroup.net NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. PLEASE REFERENCE THE MOUNT ANALYSIS REPORT FOR COMPLETE MOUNT ANALYSIS CALCULATIONS AND DETAILS. SUPPLEMENTAL PAGES INCLUDED IN THE CONSTRUCTION DRAWINGS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO VERIFY THEY HAVE THE MOST RECENT MOUNT ANALYSIS PRIOR TO CONTRUCTION. i� 1' ,;. 12. rn a a U SUPPLEMENTAL SHEET NUMBER: REVISION: R-609 0