Loading...
HomeMy WebLinkAbout014-842-22-1102-LUP-2024-571Lenroot Landing I� ,4 /2n m � nr r VICINITY MAP AMERICAN TOWER® ATC SITE NAME: SEELEY WI ATC SITE NUMBER: 311285 T-MOBILE SITE NAME: HAYWARD-ATC 311285 T-MOBILE SITE NUMBER: Al N0960A SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI 54843 SITE CLASS: SELF SUPPORT T-MOBILE CAPACITY-L1900 AMENDMENT PLAN 6790AH SR T 6X24 CONFIGURATION COMPLIANCE CODE PROJECT SUMMARY ALL WORK SHALL BE PERFORMED AND MATERIALS SITE ADDRESS: INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS 13063 WEST OLD 00 ROAD OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL HAYWARD, WI 54843 GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO COUNTY: SAWYER THESE CODES. GEOGRAPHIC COORDINATES: 2015 IBC LATITUDE:46.11106111 NATIONAL ELECTRICAL CODE (NFPA 70, NEC 2017 W/ AMND) 46" 6' 39.82" N 2015 WISCONSIN MECHANICAL CODE (IMC 2015 W/ AMND) LONGITUDE:-91.34824722 2018 WISCONSIN UNIFORM PLUMBING CODE (UPC) 91° 20' 53.69" W 2015 WISCONSIN ENERGY CONSERVATION CODE (IECC 2015 W/ AMND) GROUND EL EVATION: 1401' AMSL 2015 WISCONSIN FIRE CODE (IFC 2015 W/ AMND) WISCONSIN COMMERCIAL BUILDING CODE WISCONSIN UNIFORM DWELLING CODE (UDC) 2015 WISCONSIN FUEL GAS CODE (IFGC 2015 W/ AMND) UTILITY COMPANIES POWER COMPANY: XCEL ENERGY PHONE: (800) 895-1999 TELEPHONE COMPANY: CENTURY LINK PHONE: (800) 201-4099 Imnwwrpsn ow, Csd n,ra,�l,,ea PROJECT TEAM TOWER OWNER: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ENGINEER: ATC TOWER SERVICES LLC 1 FENTON MAIN, STE 300 CARY, NC 27511 PROPERTY OWNER: THE TOWN OF LENROOT 13063 WEST OLD 00 ROAD HAYWARD, WI 54843 APPLICANT: T-MOBILE CENTRAL LLC ATTN: BILAL BATROUKH 1400 OPUS PLACE DOWNERS GROVE, IL 60515 PROJECT DESCRIPTION THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED AND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW: TOWER WORK: REMOVE (6) ANTENNA(S), (2) RRU(S), (1) COVP, AND (1)1-5/8" NSN HIGH CAP HCS CABLE INSTALL (3) ANTENNA(S), (3) RRU(S), AND (1) 2.00" HYBRID TRUNK 6124 4AWG 90M CABLE EXISTING (3) SECTOR MOUNT(S) AND (3) RRU(S) TO BE RELOCATED GROUND WORK: REMOVE (1) MODULE STAND, (2) AMOB(S), (1) COVP, (1) SITEFLEX 3031 CABINET, (1) ASIK, (1) FSMF, AND (1) CSR 7705 SAR A INSTALL (2) ASIL(S), (1) ABIA, (4) ABIL(S), (2) AMIA(S), (1) CSR IXRE V2, (1) DELTA HPL3.05 600A DC CABINET, AND (1) DELTA LB3 BATTERY CABINET EXISTING (1) ASIA, (2) ABIA(S), AND (1) ABIL TO BE RELOCATED PROJECT NOTES 1. THE FACILITY IS UNMANNED. 2. A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE. 3. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE. 4. NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSAL IS REQUIRED. 5. HANDICAP ACCESS IS NOT REQUIRED. 6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U.S.C. § 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THAT INVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDER CFR § 1.61000 (B)(7). PROJECT LOCATION DIRECTIONS FROM ST. PAUL, MN: HEAD SE TOWARD 1-94 E. MERGE ONTO 1-94 E. STAY ON 1-94 E. TAKE THE 1-494 S EXIT. KEEP LEFT AT THE FORK, FOLLOW SIGNS FOR INTERSTATE 694 N. KEEP RIGHT AT THE FORK, FOLLOW SIGNS FOR INTERSTATE 694 N. CONT ONTO 1-694 N. TAKE EXIT 52B TO MERGE ONTO MN-36 E TOWARD STILLWATER CONT ONTO STATE TRUNK HWY 64. ENTERING WISCONSIN. CONT ONTO WI-64 EISTATE TRUNK HWY 64 E. AT THE TRAFFIC CIRCLE, TAKE THE 2ND EXIT ONTO US HWY 63 N. TURN LEFT TO STAY ON US HWY 63. TURN RIGHT ONTO US-8 ENS HWY 63 N. TURN LEFT ONTO US HWY 63 N. TURN LEFT ONTO 2ND AVE. CONT ONTO SUPERIOR AVEIUS HWY 63 N. CONT TO FOLLOW US HWY 63 N. KEEP RIGHT AT THE FORK AND MERGE ONTO US53 N. TURN RIGHT ONTO US-63 N/US HWY 63 N. DRIVE TO W - 1-.1-- T. IDI.I CI!]I.IT lfI.ITl11m! 11h1w WU mn SHEET NO: G-001 G-002 C-101 C-102 C-201 C-401 G501 — E501 E-601 LOCATION MAP BIRD WATCH SITE: PLEASE CONTACT BIRD.WATCH@AMERICANTOWER COM OR AMERICAN TOWER NOC AT 877-518-6937 FOR ASSISTANCE SHEETINDEX DESCRIPTION: TITLE SHEET — GENERAL NOTES DETAILED SITE PLAN DETAILED EQUIPMENT PLAN TOWER ELEVATION ANTENNA INFORMATION & SCHEDULE CONSTRUCTION DETAILS GROUNDING DETAILS PANEL SCHEDULE & ELECTRICAL SCHEMATIC SUPPLEMENTAL SHEETS (9 PAGES) REV: DATE: BY: 0 11/2012024 EDNA EDNA EDNA 0 11/20/2024 0 11/20/2024 0 11/20/2024 EDNA 0 '11120/2024 EDNA 0 1112012024 EDNA 0 11/2012024 EDNA 0 11/20/2024 EDNA 0 11/20/2024 EDNA I 1 AMERICAN TOWER' ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 466-0112 4069-11 1 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER 1 IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV- DESCRIPTION BY DATE A0 FOR CONSTRUCTION EDNA11120/202 0 - - n ATC SITE NUMBER: 311285 ATC SITE NAME: SEELEY WI T-MOBILE SITE NAME: HAYWARD-ATC 311285 SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI 54843 SEAL: ��j1L1111 a lrrrrr�� ,,`rflffr�,i \5 C 0 Ns �N SANTHOSHA SHANBHOGUE -o E-49097 Val CARY NC signed ;antho(140Cy► by Santhosha ►hanbhog Shanbhogue Date: 2024.11.20 ID T ..Mobilei ATC PROJ. #: 14907585 GO COST. ID: HAYWARD-ATC 311285 COST. #: Al N0960A TITLE SHEET SHEET NUMBER: REVISION: G-001 0 I GENERAL CONSTRUCTION NOTES: 1 OWNER FURNISHED MATERIALS, T-MOBILE -THE COMPANY- WILL PROVIDE AND THE CONTRACTOR WILL INSTALL A BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUND BUILDICO-LOCATE ONLY) B. AC/TELCO INTERFACE BOX (PPC) C. ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GC TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION) D. TOWERS, MONOPOLES E. TOWER LIGHTING R GENERATORS 8 LIQUID PROPANE TANK G. ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING H. ANTENNAS (INSTALLED BY OTHERS) I. TRANSMISSION LINE J. TRANSMISSION LINE JUMPERS K. TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITS L. TRANSMISSION LINE GROUND KITS M. HANGERS N. HOISTINGGRIPS O. BTS EQUIPMENT 22. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR ALL REQUIRED PERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THE CONTRACTOR. 23. CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILE SPECIFICATIONS AND REQUIREMENTS. 24 CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 25. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND AS SHOWN IN THESE PLANS. WEATHER SEALED WITH RFS CONNECTORSISPLICE WEATHERPROOFING KIT #221213 OR EQUAL. B ALL COAXIAUHYBRID CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIAUHYBRID CABLE (NOT WITHIN BENDS) ELECTRICAL NOTES: 1 ELECTRICAL DESIGN SHALL BE PERFORMED BY ELECTRICAL CONTRACTOR STRUCTURAL DESIGN SHALL BE PERFORMED BY GENERAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL ENSURE THAT ALL WORK COMPLIES WITH ALL APPLICABLE LOCAL AND STATE CODES AND NATIONAL ELECTRICAL CODE, ALL SUGGESTED ELECTRICAL ELEMENTS (SUCH AS BREAKER SIZES, WIRE SIZES, CONDUITS SIZES ARE FOR ZONING PURPOSES ONLY, IT IS THE RESPONSIBILITY TO OF THE ELECTRICAL CONTRACTOR TO CONFIRM COMPLIANCE WITH LOCAL ELECTRICAL CODES AND PASS ALL APPLICABLE AND NECESSARY INSPECTIONS. IN SOME EVENTS, IT MAY BE NECESSARY TO PERFORM AN ELECTRICAL LOAD STUDY TO VERIFY THE CAPACITY OF THE EXISTING SERVICE. THIS IS NOT THE RESPONSIBILITY OF CONCORDIA IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR 2 THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE APPROVA 3 CONTRACTOR SHALL FIELD LOCATE ALL BELOW GRADE GROUND LINES AND UTILITY COMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCH LINES PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR RELOCATION OF MATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB -FRAME FOR PLATFORM, 28. WHEN THE PROJECT SCOPE REQUIRES THE USE OF THE SAFETY CLIMB, THE GENERAL ALL UTILITIES AND GROUND LINES THAT MAY BECOME DISTURBED OR CONFLICTING IN ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES, CONTRACTOR SHALL ENSURE THE SAFETY CLIMB IS FREE OF OBSTRUCTIONS NOT THE COURSE OF CONSTRUCTION. COPPER -CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER, CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS AND RUBBER MATTING, REPAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS, MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES AND ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO 29. THE DRAWINGS AND SPECIFICATIONS. IT IS THE POSITION OF T-MOBILE TO APPLY FOR PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED PERMITS. 30 3 ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING ANSIIEIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS. 4 CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. 5 CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED INSPECTIONS. 6 ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND SITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALL DISCREPANCIES REPORTED TO THE ENGINEER- 7 DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS 8 DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. 9 THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 26. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. 2 THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT 27 CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR SEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW AND L RUBBING ON OR TRAPPED BY ANY INSTALLED CUSTOMER EQUIPMENT, IS VISUALLY TAUT, MEETS MANUFACTURER INSTALLATION SPECIFICATIONS, AND IS FIRMLY SECURED AT ALL CABLE GUIDE LOCATIONS UPON PROJECT COMPLETION. COMPLETION OF PROJECT SHALL NOT OBSTRUCT, TRAP, LOOSEN, OR OTHERWISE CAUSE FAILURE TO MEET MANUFACTURER INSTALLATION REQUIREMENTS FOR THE SAFETY CLIMB CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITH ALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALL NECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICES SUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING, TRENCH BOXES/SLOPING, BARRIERS, ETC. 31. THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANY DAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HIS WORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS EXPENSE TO THE OWNER'S SATISFACTION. 32. ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIP SHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANYWORKFOUNDBY THE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BE REPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS OBTAINED. 33. IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF MATERIALS LISTED HEREINAFTER BY MANUFACTURER'S NAMES AND/OR MANUFACTURER'S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERS AS SPECIFIED. 10. CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING, 34 ANCHOR BOLTS, ETC 11 CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS DRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK. 12 INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR 35 NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILE REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALL REQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING. 13 EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. 14. CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION -THIS PROJECT TO MATCH EXISTING PRE -CONSTRUCTION CONDITIONS TO THE SATISFACTION OF THE T-MOBILE CONSTRUCTION MANAGER 15. ALL CABLEICONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURING INSTALLATION USING A SILICONE SEALANT. 16 WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET, CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORD IMMEDIATELY. 17. CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE AND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. 18. CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF EACH DAY. 19. CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWER CORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY. 20. CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC) WITH A PDF MARKED UP AS -BUILT SET OF DRAWINGS UPON COMPLETION OF WORK. T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED -UP AT THE T-MOBILE WAREHOUSE, NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTED AND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACE THE EQUIPMENT IN OPERATION, READY FOR USE THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP. T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANY EQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH THE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THE EQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO T-MOBILE OR THEIR ARCHITECT/ENGINEER. SPECIAL CONSTRUCTION ANTENNA INSTALLATION NOTES: 1. WORK INCLUDED: A. ANTENNA AND COAXIAUHYBRID CABLES ARE FURNISHED BY T-MOBILE UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS. ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PERSONNEL B INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND T-MOBILE SPECIFICATIONS. C. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS. D INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE AND PROVIDE PRINTOUT OF THAT TEST. E INSTALL COAXIAUHYBRID CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL CONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. TERMINATE ALL COAXIAUHYBRID CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED. 21. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDED SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALL 2• ANTENNA AND COAXIAUHYBRID CABLE GROUNDING: ALL ITEMS PROVIDED. A. ALL EXTERIOR #6 GREEN GROUND WIRE 'DAISY CHAIN' CONNECTIONS ARE TO BE ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESE CONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATC ENGINEERING IMMEDIATELY FOR CORRECTION OR RE -DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING OR ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. i C i AMERICAN TOWER• _ ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 E PHONE: (919) 468-0112 4069-11 f THE USE AND PUBLICATION OF THESE DRAWINGS 1 SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION, REV. DESCRIPTION BY DATE /0 FOR CONSTRUCTION EDNA11/2012024 nn ---- ATC SITE NUMBER: 311285 ATC SITE NAME: SEELEY WI T-MOBILE SITE NAME: HAYWARD-ATC 311285 SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI54843 SEAL: 'j11111111111l►�//, tt0 �r5 C 0 NSA'%, SANTHOSHA SHANBHOGUE E-49097 CARY o :.n NC -' ��►Illlllllilll Digitally Signed: 2024-11-20 m ! -Mobile - PROD. #: 14907585 GO LATC CUST. ID: HAYWARD-ATC 311285 CUST.# AlN0960A GENERAL NOTES SHEET NUMBER: REVISION: G-002 0 SITE PLAN NOTES: 1 THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2. ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, To INSTALLING NEW PORTS OR ANY OTHER EXISTING T-MOBILE — EQUIPMENT, CONTRACTOR SHALL VERIFY ALL METER AND SERVICE ASPECTS OF THE COMPONENTS MEET THE ATC MAIN DISCONNECT T SPECIFICATIONS. X - X — Q 3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR K LC 1.1 0 TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY T FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR X X ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. CONDUIT x x 4' x 6' _ ] 1 1 '-7" X 25'-0CON. PAD SHELTER SELF SUPPORT 'GRAVEL I8 TOWER SURFACE LEGEND x x ® GROUNDING TEST WELL ATS AUTOMATIC TRANSFER SWITCH AV B BOLLARD CSC CELL SITE CABINET 6' H-FRAME D DISCONNECT EXISTING E ELECTRICAL AV (1) 1-5/8" NSN HIGH CAP HCS CABLE � F FIBER x /B _ (TO BE REMOVED) x3Lf GEN GENERATOR 1,000 GALLON G GENERATOR RECEPTACLE PROPANE TANK — PROPOSED (1) 2.00' HYBRID TRUNK ON A 6/24 4AWG 90M CABLE + HH, V HAND HOLE, VAULT IB ICE BRIDGE 4'-7" X 10'-0" ❑ �l i NOTES ON THIS PAGE(SEE PROPOSED LFORILENGGTH T PAD H }r K KENTROX BOX CON PAD ` _ /I AND ROUTING GUIDELINES) LC LIGHTING CONTROL .7 M METER X X X k PB PULL BOX PP POWER POLE T TELCO EXISTING T-MOBILE TRN TRANSFORMER 10' NO SPARK 8' X 8' PLATFORM/PLINTH 1 2 BUFFER ZONE WITHIN A CHAINLINK FENCE 1O' X 12' GROUND SPACE 10 (MODIFIED AS REQUIRED FOR PROPOSED CABLE NOTES: UPGRADE FROM 6700H R4 TO 6790AH-SR T 6X24 CONFIGURATION) 1. ESTIMATED LENGTH OF PROPOSED CABLE IS 307'. ESTIMATED LENGTH OF CABLE WAS PROVIDED BY CUSTOMER OR CALCULATED BY ADDING THE RAD CENTER AND THE DISTANCE FROM THE SHELTER ENTRY PLATE TO THE TOWER (ALONG THE ICE BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF 15% (OF THE TWO PREVIOUS VALUES), CDS DEFER TO GREATEST CABLE LENGTH. 2. ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE EXISTING CABLE SUPPORT STRUCTURES AS DETAILED SITE PLAN PROVIDED FOR CARRIER TO ADEQUATELY SECURE CABLES, USING EITHER APPROPRIATELY SIZED GRAPHIC SCALE STAINLESS STEEL SNAP -INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE 20 0 10 20 MANUFACTURER. OTHERWISE, ATTACH CABLES TO HORIZONTAL OR DIAGONAL TOWER MEMBERS USING PROPOSED STAINLESS STEEL ADAPTERS (DO (IN FEET) NOT ATTACH TO TOWER LEG). 1 UNIT = 20 FEET 1 i i i AMEMCAN TOWER• ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR i WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE QOROjsTRUCTIDN EM(IAJ&0120P4 0 0 0 0_ _ ATC SITE NUMBER: 311285 ATC SITE NAME: SEELEY WI T-MOBILE SITE NAME: HAYWARD-ATC 311285 SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI 54843 SEAL: •��: ��• SANTHOSHA SHANBHOGUE -o E-49097 CARY w Nc 2: 'OIhi At`'�� Digitally Signed: 2024-11-20 T - -Mobile ATC PROJ. #: 14907585 GO COST. ID: HAYWARD-ATC 311285 COST. #: Al N0960A DETAILED SITE PLAN SHEET NUMBER: REVISION: C-101 0 1. CONTRACTOR TO VERIFY THERE IS NO LIVE AAV FIBER RUNNING THROUGH EXISTING DEAD EQUIPMENT. IF SO, THIS WILL NEED TO BE RERUN THROUGH CONDUIT PRIOR TO REMOVING DEAD 2G (6201 CABS) EQUIPMENT. 2. ALL OPEN PORTS NEED TO BE SEALED / WEATHERPROOFED PROPERLY 3. ALL UNNEEDED / EXCESS EQUIPMENT AND GARBAGE TO BE REMOVED FROM EQUIPMENT AREA. DISPOSE OF MATERIALS PROPERLY OFF SITE. EXISTING GPS ANTENNA EXISTING AMOB (TO BE REMOVED) EXISTING MODULE STAND AND AMOB (TO BE REMOVED) EXISTING 8' X 8' PLATFORM EXISTING SITEFLEX 3031 CABINET (TO BE REMOVED) EXISTING (1) ASIA, (2) ABIA, AND (1) ABIL (TO BE RELOCATED) EXISTING (1) ASIK, (1) FSMF, AND (1) CSR 7705 SAR A (TO BE REMOVED) EXISTING 10' X 12' LEASE AREA EXISTING PPC T-MOBILF CM APPROVAL REQUIRED BEFORE INSTALLING CABINETS. EXISTING ICE BRIDGE PROPOSED (1) 2.00- HYBRID TRUNK 6/24 4AWG 90M CABLE (SEE PROPOSED CABLE LENGTH NOTES ON PAGE C-101 FOR LENGTH AND ROUTING GUIDELINES) EXISTING - GPS ANTENNA EXISTING RELOCATED I a (1) ASIA, (2) ABIA, AND (1) ABIL I EXISTING 8' X 8' PLATFORM ' 1� \ . -.I-- )�7 f-161 i n EXISTING 10' X 12' LEASE AREA I PROPOSED DELTA ®1 HPL3.05 600A DC CABINET -0p PROPOSED (2) ASIL, (1) ABIA, (4) ABIL, (2) AMIA, AND (1) CSR IXRE V2 INSIDE 1 PROPOSED HPL3.05 CABINET i PROPOSED DELTA LB3 i I BATTERY CABINET 60 PROPOSED 1 1 i CONDUITS -00 -80 I � EXISTING PPC I EXISTING H-FRAME EXISTING FIBER BOX EXISTING GROUND EQUIPMENT LAYOUT 2 PROPOSED GROUND EQUIPMENT LAYOUT GRAPHIC SCALE GRAPHIC SCALE 3 0 1.5 3 �f 3 0 1-5 3 ■r (IN FEET) (IN FEET) +'f 1 UNIT = 3 FEET 1 UNIT = 3 FEET 1 f i AMEREGAN TOWER' ATC TOWER SERVICES LLC c 1 FENTON MAIN SUITE 300 a CARY, NC 27511 PHONE: (919) 468-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE 0o FoRCm( NSTRUC7YON EDNA11/20/2024 0 r ; _ ATC SITE NUMBER: 311285 ATC SITE NAME: SEELEY WI T-MOBILE SITE NAME: HAYWARD-ATC 311285 SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI54843 SEAL: c 1ti', •Y SANTHOSHA,� SHANBHOGUE E-49097 CARY NC Z: Digitally Signed: 2024-11-20 T - -Mobil ATC PROJ. #: 14W7685_G0 CUST. ID: HAYWARD-ATC 311285 CUST. #: Ai N0960A DETAILED EQUIPMENT PLAN SHEET NUMBER: REVISION: C-102 0 9 TOP OF EXISTING OIL HIGHEST APPURTENANCE ELEV 256.29' OIL TOP OF EXISTING TOWER ELEV 250.55' 2 1 EXISTING AN IO �0 PROPOSED T-MOBIL EQUIPMEN EXISTIN (1) 1-5/8" NSN HIGH CAP HCS CABL (TO BE REMOVE[ PROPOSED (1) 2.00" HYBRID TRUNK 6 4AWG 90M CABLE (3( (SEE CABLE NOTES ON C-1 &TOWER ELEVATION SCALE: N T.S. EXISTING CARRIER ANTENNAS RAD CENTER ® ELEV 244.9' PROPOSED T-MOBILE RAD CENTER Q 235' IV EXISTING CARRIER ANTENNAS jk RAD CENTER ® ELEV 215'- V =XISTING TOWER EXISTING GRADE 05. ELEV 0' PER MOUNT ANALYSIS COMPLETED BY ATC, DATED 10/31/24, THE EXISTING MOUNT CAN ADEQUATELY SUPPORT THE PROPOSED LOADING. z tr t rn AMWER• a ATC TOWER SERVICES LLC 1 FENTON MAIN 3 SUITE 300 ° CARY, NC 27511 0 PHONE: (919) 468-0112 4069.11 THE USE AND PUBLICATION OF THESE DRAWINGS D_ SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED, ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT, CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE A0 FOR CONSTRUCTION EDNA11121N2024 A 0 ATC SITE NUMBER: 311285 ATC SITE NAME: SEELEY WI T-MOBILE SITE NAME: HAYWARD-ATC 311285 SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI 54843 SEAL: .�•''�51c SANTHOSHA SHANBHOGUE -o E-49097 CARY w .� NC ••fir/ t \ti'• Digitally Signed: 2024-11-20 T r .Mobile, ATC PROJ. #: 14907585 GO CUST. ID: HAYWARD-ATC 311285 CUST.M AIN0960A TOWER ELEVATION SHEETNUMBER: REVISION: C-201 0 PER MOUNT ANALYSIS COMPLETED BY ATC, DATED 10/31/24, THE EXISTING MOUNT CAN ADEQUATELY SUPPORT THE PROPOSED LOADING. EXISTING TMBXX-6517—A2M ANTENNA (TO BE REMOVED) (1 PER SECTOR) (TYP. 3) 0 2 o a N Q Q Q EXISTING EXISTING TOWER — PROPOSED FFW-65GR2N23 �1 EXISTING TOWER Q FF-65C—RI ANTENNA ANTENNA (TO BE REMOVED) (1 PER SECTOR) (TYP. 3) 501 (1 PER SECTOR) (TYP. 3) EXISTING AHLOA RRU Al A2 EXISTING RELOCATED -- Al (TO BE RELOCATED AHLOA RRU TO W RAP. (1 PER SECTOR) (TYP. 3) PROPOSEDII RRUTYP. (1 PER SECTOR) 8) PER SECTOR) 3) 50 � EXISTING ASU9338TYPOl COVP — — (TO BE REMOVED) (TYP. 1) 7A� EXISTING RELOCATED SECTOR MOUNT 2A0 P� P G2 EXISTING C1 7� �pA (1 PER SECTOR) (TYP. 3) Gp� (TOh 4 C1 B 1 Q2 EXISTING SECTOR MOUNT' 72 e (TO BE RELOCATED 4 gyp' 9 �1 TO NEW RAID)q (1 PER SECTOR) (TYP. 3) 1 EXISTING ANTENNA PLAN k 2 FINAL ANTENNA PLAN N SCALE: N.T.S. SCALE: N T.S. EXISTING ANTENNA SCHEDULE NOTES FINAL ANTENNA SCHEDULE LOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY 1. GC TO VERIFY THE FINAL RFDS LOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY MATCHES THE FINAL MECHIELEC ADDITIONAL TOWER MECHIELEC ADDITIONAL TOWER SECTOR RAID AZ POS ANTENNA BAND STATUS STATUS CONSTRUCTION DRAWINGS. SECTOR RAIDAZ POS ANTENNA BAND STATUS STATUS D-TILT MOUNTED EQUIPMENT GC TO NOTIFY ATC PM OF ANY D-TILT MOUNTED EQUIPMENT � _ DISCREPANCY PRIOR TO ,,,, Al TMBXX-6517—A2M L1900,U1900 0�2' RMV N600L700L600L2100 — T AHLOA REL ALPHA 231' 0' — INSTALLING THE EQUIPMENT. ALPHA 235' 0' Al FFW-65C-R2N23 L1900,141900,1-12AWS3, 0'',2' ADD AHFII ADD A2 FF-65C—R1 L700,N600,L600 0%2- RMV AHLOA REL 2. GC TO CAP ALL UNUSED N2100 B 1 TMBXX-6517—A2M L 1900, U 1900 0%2- RMV (2) FXFC RMV PORTS. N600,L700,L600,L2100, BETA 231 ' 120' 3. GC TO CONFIRM SPACING OF BETA 235' 120' B1 FFW-65C-R2N23 L1900,N1900,LAWS3, O'12 x ADD AHLOA REL B2 FF-65C—R1 L700,N600,L600 0%2' RMV AHLOA REL PROPOSED EQUIP DOES NOT N2100 AHFII ADD C1 TMBXX-6517—A2M L1900,U1900 0- 2' RMV CAUSE TOWER CONFLICTS — GAMMA 231' 240' NOR IMPEDE TOWER CLIMBING N600,L700,L600,L2100, AHLOA REL C2 FF-65C—R1 L700,N600,L600 0%2' RMV AHLOA REL PEGS. GAMMA 235' HC1 FFW-65C-R2N23 L1900,N1900,LAWS3, O'I2',2' ADD AHFII ADD STATUS ABBREVIATIONS N2100 RMV: TO BE REMOVED RMN: TO REMAIN REL: TO BE RELOCATED ADD: TO BE ADDED CABLE LENGTHS FOR JUMPERS JUNCTION BOX TO RRU: 15' RRU TO ANTENNA: 1 V EXISTING FIBER DISTRIBUTION I OVP BOX EXISTING CABLING SUMMARY FINAL FIBER DISTRIBUTION I OVP BOX FINAL CABLING SUMMARY MODEL NUMBER STATUS CABLE QTY, SIZE, TYPE STATUS EQUIPMENT SCHEDULES MODEL NUMBER STATUS CABLE QTY, SIZE, TYPE STATUS (1) ASU9338TYP01 RMV (1) 1-518" NSN HIGH CAP HCS RMV 3 - (1) 2.00' HYBRID TRUNK 6/24 4AWG 90M CABLE CABLE ADD i 1 AMEMCAN TOWER• ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 i THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER i IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE 00_ FOR CONSTltIJl1_O�l. IrpNA11120J20[n 0 0 _ 0 -- A ATC SITE NUMBER: 311285 ATC SITE NAME: SEELEY WI T-MOBILE SITE NAME: HAYWARD-ATC 311285 SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI 54843 SEAL: ``1tt0til.ei •-: SANTHOSHA SHANBHOGUE E-49097 Ix CARY o NC '7jl1l111111111111� Digitally Signed: 2024-11-20 T - -Mobile ATC PROJ. #: 14907585 GO COST. ID: HAYWARD-ATC 311285 COST.#: AIN0960A ANTENNA INFORMATION & SCHEDULE SHEET NUMBER: REVISION: C-401 0 EXISTING/PROPOSED MOUNTS AND/OR MOUNT MODIFICATIONS NOT SHOWN FOR CLARITY. REFER TO ANTENNA PLANS, MOUNT ANALYSES AND/OR MOUNT MODIFICATION DOCUMENTS FOR ADDITIONAL DETAIL. EXISTING OR PROPOSED MOUNTING PIPE PROPOSED ANTENNA DOWNTILT BRACKET (PER MANUFACTURER) (INSTALL THIRD BRACKET IF REQUIRED) PROPOSED ANTENNA 4 PROPOSED ANTENNA MOUNTING DETAIL - TYPICAL SCALE: N.T.S PROPOSED M12 BOLTS (TYP. 4) THROUGH PLATFORM PROPOSED CABINET EXISTING PLATFORM 'Wr 3 CABINET ATTACHMENT TO PLATFORM SCALE: N.T.S. PROPOSED RRU (TYP.) (MOUNT PER MANUFACTURER'S SPECS) (ENSURE THAT BRACKET DOES NOT CONFLICT WITH EXISTING OR PROPOSED EQUIPMENT) PROPOSED RRU MOUNTING HARDWARE (INCLUDED WITH RRU) EXISTING OR PROPOSED MOUNTING PIPE PROPOSED RRU MOUNTING DETAIL - TYPICAL SCALE: N T S. c i AMERICAN TOWER' _ ATC TOWER SERVICES LLC e 1 FENTON MAIN SUITE 300 c CARY, NC 27511 PHONE: (919) 468-0112 4069-11 c THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR i DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE 00 FOR CONSTRUCTION EDNA1117.UI7.0[A 0 0_ -. ATC SITE NUMBER: 311285 ATC SITE NAME: SEELEY WI T-MOBILE SITE NAME: HAYWARD-ATC 311285 SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI 54843 SEAL: 1j111ff111111A1,1���� 0/1 Iy = SANTHOSHA =_ SHANBHOGUE E-49097 CARP w NC • Digitally Signed: 2024-11-20 T - -Mobile ATC PROJ. #: 14907585 GO COST. ID: HAYWARD-ATC 311285 COST.#: AlN0960A CONSTRUCTION DETAILS SHEET NUMBER: REVISION: C-501 0 EXISTING ANTENNAS TO EXISTING ANTENNA MASTS PROPOSED ANTENNA - PROPOSED JUMPER - PROPOSED CONNECTOR AND WEATHERPROOFING KIT - PROPOSED WEATHERPROOFING KIT EXISTING GROUND KITS GROUND KIT I I f �= PROPOSED CABLE 501 1 PROPOSED #6 AWG STRANDED CU , (J� ` ANTENNA CABLE TO CABINET (TYP.) WIRE WITH GREEN, 600V, I` THWN INSULATION ' TO PROPOSED RRU I I 1 GROUND LUG (TYP.) I ` �_ \ ' #6 AWG STRANDED CU � e WIRE WITH GREEN, 60OV, 1 THWN INSULATION GROUND/NG CONNECTION TO EXISTING TMAs EXISTING GROUNDING CONNECTION TO r GROUND BAR MOUNTED ANTENNA IF 501 LIGHTNING (TO BE INSTELOWALLED (TO BE INSTALLED PROTECTION SYSTEM REQUIRED) NOTES: 1. THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHT ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THE CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THE CONSTRUCTION MANAGER OF ANY CONFLICTS. 2. SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATEST EDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN. G TYPICAL ANTENNA GROUNDING DIAGRAM SCALE: N.T.S. TO ANTENNA ANTENNA CABLE 2 1/2"0 MAX GROUNDING KIT PER CABLE MANUFACTURER'S RECOMMENDATIONS (ANDREW OR APPROVED EQUAL) #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) TO GROUND BAR TO EQUIPMENT GROUND KIT NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PART NUMBER 221213) AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS, CABLE GROUND KIT CONNECTION DETAIL SCALE: N.T.S. STANDARD CONDUIT USE TABLE CONDUIT USE CASE LOCATION USE CASE EXAMPLE TYPE RMC ABOVE GROUND (METALLIC) AC, DC COMM ABOVE GROUND PPC TO SSC UNDERGROUND PPC TO SSC OR BACKHAUL PVC AC POWER UNDERGROUND TRANSPORT HUB TO SSC MAX 6' PER CONDUIT RUN, TIGHT LOCATIONS BETWEEN HUB AND CONDUIT BUT NOT LFMC AC, DC, COMM ABOVE GROUND ONLY TO BE USED WHERE IT CAN BE STEPPED ON EMT INDOOR AC, DC INDOOR NOT EXPOSED TO THE OUTDOOR CIRCUIT PANEL TO JUNCTION BOX COMM ENVIRONMENT (MUST BE DRY) LFNC GROUND CONCEALING AND PROTECTING BTCW RISERS GROUND RING TO MGB OR SSC WIRE ONLY EXCEPTION CONDUIT USE TABLE CONDUIT USE CASE LOCATION USE CASE EXAMPLE TYPE EMT OUTDOOR DC, OUTDOOR WHEN USED WITH WATERTIGHT BETWEEN EQUIPMENT AND BATTERY CABINET OR (NOT PREFERRED) COMM HUBS ONLY EQUIPMENT TO EQUIPMENT CABINETS FOR INTER CABINET CONNECTION RMC OUTDOOR/INDOOR MAT BE USED AS A LOWER COST ALTERNATIVE TO NONMETALLIC NEC PER NEC ABOVE GROUND METALLIC RMC, MUST MEET OR EXCEED FEDERAL SPEC: (ALUMINUM) GUIR WW-C-540C, UL-6A, ANSI C80.5, NEC 344.10 (A) ALLOWS THE USE OF EITHER ALUMINUM OR GALVANIZED FITTINGS 4 CONDUIT USE TABLES PROPOSED CABINET #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR EXISTING EQUIPMENT GROUND BAR (TYP.) CABINET GROUNDING DETAIL SCALE: N.T.S. 3/8" X 1-1/2" SS BOLT 3/8" SS LOCK WASHER (EACH SIDE) (EACH SIDE) N Ar /" Ao qr 1/4" X 4" X 6" GROUND BAR (ERICO PIN: EGBA14406CC OR EQUAL) TWO -HOLE LUG, TO BE USED WITH #2 AWG BOW (LOWER TOWER GROUND BAR ONLY) GROUND BAR NOTES: 1. GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS, WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). 2. GROUND BAR TO BE BONDED DIRECTLY TO TOWER. TOWER GROUND BAR DETAIL J SCALE: N T S ELECTRICAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. 2. ATC HAS NOT VERIFIED ANY EXISTING T-MOBILE GROUND EQUIPMENT OR ELECTRICAL LOADING. PROPOSED WORK BASED ON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE. CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HAS SUFFICIENT SPACE FOR PROPOSED BREAKER. PROPOSED CABLE AND CONDUIT SHALL BE MINIMUM SIZE PER BELOW IN CHART. 3. FOR SPECIFIC CABINET / ANCILLARY EQUIPMENT WIRING REQUIREMENTS, THE T-MOBILE CONTRACTOR SHOULD REFERENCE DESIGN DOCUMENTS PROVIDED BY T-MOBILE FOR THIS CURRENT PROJECT CONFIGURATION, IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS & NEC STANDARDS & PRACTICES. VOLTS OCPD SIZE WIRE SIZE I GROUND CONDUIT 120/240V OR 120/208V 8OA/2P 343AWG #8AWG 1-1/4" 100/2P 342AWG #0AWG 1-1/4" 125A/2P 3413M AWG 96 AWG 2" 15OA/2P "3/0 AWG #6 AWG 2" 200A/2P 3413/0 AWG #6 AWG 2" 240V OR 208V BOAl2P 2-#3AWG #8AWG 1-1/4" 100/2P 2-#2AWG #8AWG 1-1/4" 125A/2P 241NO AWG #6 AWG 2" 15OAQP 249M AWG #6 AWG 2" 200Af2P 243/0 AWG #6 AWG 2" B ELECTRICAL NOTES C m m t AMERICAN TOWER' ATC TOWER SERVICES LLC J 1 FENTON MAIN SUITE 300 a CARY, NC 27511 y PHONE: (919) 468-0112 a 4069-11 ° THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR : WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES a TO AMERICAN TOWER OR THE SPECIFIED CARRIER Ly IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE ,o _FQR CONBTRUCTKIN EONAm20/$024 A --- 0 ATC SITE NUMBER: 311285 ATC SITE NAME: SEELEY WI T-MOBILE SITE NAME: HAYWARD-ATC 311285 SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI 54843 SEAL: it jjjjtl� c� SANTHOSHA SHANBHOGUE E-49097 UIR :.� NC -" ie 1111/01 /1111111 Digitally Signed: 2024-11-20 T - -Mobile= ATC PROJ. #: 14907585_GO CUST. ID: HAYWARD-ATC 311285 CUST. #: AIN0960A GROUNDING DETAILS SHEET NUMBER: REVISION: E-501 0 PANEL TYPE UGITING B APPLIANCE SYST3vt 120/24OV, 10, 3W, 30 CKT LOCATION: TENANT H7I.PirBNT LEASEAREA Dmr"Tim TENANTPAIYEL MINTING: SLWACE MAN SPEAKER(MB): 200A ENCLOSLPE NEMM 3R MAN BI.IS RATING: 200A PANS NOTES: BMTNG MR A I C RATING: RA F®HROREIMNUIC KM ORB�fJ7'�CMVCL_R_ CON'! BRIEF DESCRIPTION BRE M C>AC7.lf Pg1,pw _ .. POLE Ck�.1JlT SRCAKER BW DESCRIPTION LOAD(WA) AMB •POLES VNRE GND CON0. NO.���NO. CCND. GND WIRE POLES AMPS A B 2 1 15 GPI OjTL 018 ELIOAAD(WA) SLMGE 30 2133 1 4 am HPL3.05 EKPANSION 100 2 3-Ni NB 2" 6 6g000 LKiFTIS S5 1 9 3 10 0-� 0.18 GTIi5 1 11 3 12 D,DD I2-75 DELTA HPL3.06 200 2 34M N6 7, 15 13 4 14 DAO 12.76 16 0,00 0.18 HPL3.05 OA 20 1 2912 w2_ 17 4 16 0.00 9,110 19 20 D.DO ODD 21 22 ODD 0A0 2i 24 O.OD ODD 25 26 + O.OD 0.. 27 28 - 0.00 0.00 29 30 ODD 18.7 182 A E 7aTAL 0.2 0.0 18.E 1&2 $7.1 CC�LOAD(WA) 189 18-2 37.1 a30ANDLOAD$VA) DERATING FACTOR(80%) CRQJTNOTES DEMANDLOAD SIZING: 193 AMPS 1) PANEL SCHEDLILE BASED ON INFO PROJEEDMAE; F PANEL HAS OIFFERENT EXISTING LOADS THAN SHOWN, STOP WOW AND OONTACT FOR 2) EXISTING CRCUfT, LM40M LOAD, MAX DEMAND ASSLNED FOR LOAD CAPACITY ASSESSMENT. 3) EXISTING CIRCUIT, KNOWN LOAD FOR LOAD CAPACITY ASSESSMENT 4) PROPOSED CIRCUT, KNOWN LOAD FOR LOAD CAPACITY ASSESSMENT 5) EXISTING CIRCUIT DEMCID 6) BMTINGOROKDEMCID. BREAKER REPLACED AS SHOWN ANDCK"TAS PROPOSED, KNOWN LOAD FOR LOAD CAPACITY ASSESSMENT 1 PANEL SCHEDULE Lit/J ///VL PROPOSED BREAKI (SEE PANEL SCHEDUI ELECTRICAL NOTES: 1. THIS DIAGRAM REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. 3. ATC HAS NOT YET VERIFIED ANY EXISTING T-MOBILE GROUND EQUIPMENT OR ELECTRICAL LOADING. PROPOSED WORK BASED ON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE. CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HAS SUFFICIENT SPACE FOR PROPOSED BREAKER. { PROPOSED POWER CIRCUIT (SEE PANEL SCHEDULE) PROPOSED DELTA HPL3.05 CABINET (INSTALLED AND CONNECTED AS DIRECTED BY T-MOBILE) PROPOSED DELTA BATTERY CABINET (INSTALLED AND CONNECTED AS DIRECTED BY T-MOBILE) -11 TERMINATE PER MANUFACTURER'S SPECIFICATIONS D ELECTRICAL SCHEMATIC SCALE: N. T. S EXISTING T—MOBILE PLATFORM { EXISTING GRADE S E 2 9 4 D IS AMERICAN TOWER• ATC TOWER SERVICES LLC 1 FENTON MAIN - SUITE 300 - CARY, NC 27511 L PHONE: (919) 460-0112 c 4069-11 `n c _ THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED ANY USE ORI DISCLOSURE OTHER THAN THAT WHICH RELATES i TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE /0 _ FOR CQNWRUCTION EDNA11/2012024 A n ATC SITE NUMBER: 311285 ATC SITE NAME: SEELEY WI T-MOBILE SITE NAME: HAYWARD-ATC 311285 SITE ADDRESS: 13063 WEST OLD 00 ROAD HAYWARD, WI 54843 SEAL: IIV1/1, �•N'''►►►5 C 0 SANTHOSHA SHANBHOGUE -p E-49097 = CARY NC girl1l 111►►►► Digitally Signed: 2024-11-20 T - -Mobile-- ATC PROJ. #: 14907585 GO COST. ID: HAYWARD-ATC 311285 CUST. #: I Al N0960A PANEL SCHEDULE & ELECTRICAL SCHEMATIC SHEET NUMBER: REVISION: E-601 0 Proposed RAN Equipment Template: 6790AH-SR T-Bx24 Enclosure 1 2 3 Enclosure Type TMW Tap Mount (Nowo De11a L63 B." Cabinet (4 strinp>E] Delta-wL3.05 E00A 94a Support Cabinet Radio A}1Ff1 jail AHLOAIpt3) N19DD N600 N2100 (DARK) L600 L1900 L 0 L2100 LAW53 tt)ARH' i ASIA ASILla2) Baseband L60D N60D L700 N 1900 L1900 tt2t410 (CIARK) �L2100 Baseband Submoduie �WS3 (DARI0. A91A ABIA(s2) frLaM L19w ABILix2) N600 L700 L2100 WSa (DARK) ABI1 (rt3j f N1$OD f ht(ps:110ds.intern at.t-mobi le- comidatasheetlprintoutlBb2acc98-029d-4I)61-a32f-96018B0h2e921661 ecc7b-a044-43h8-9245-ec14egg 68a0A 5112 1018124, 9:08 AM t N2100(DARK) Baseband Subrack Transport System Hybrid Cable System RAN Scope of Work: r 10l0412024-SK- PRFDS Created Al N0960A-C apacq-L i 900_3_preliminary_2024-10.06 CAMtIA pt 2) �R IxRe V2 (Gen2)� 14p, rid Trunk &24 4AWG 90m) CABINET CONFIGURATION r - 679W "R T_: ll -NOLMM -Ipg Configuration 6790A H_SR " For 5G and LTE Airscale 13D dimensioning refer to Fiber Port matrices. (Alpha, Beta & Gamma) 60 Airscale rr n wrl Too+60D FDD - Lowband B12 (L700) - 5 MHz 871 (L600) -10 MHz 071 (N600) -15 MHz FDD - Midband B4JB66 (1-2100) - 20 MHz U66 (N1NO) -2UMHz 82 (L1900) - 20 MHz 82S (L1900)-20 MHz 825 (N1900)-20MHz TDD - Band 41 N41(2.SGHz)-100MHz +90MHz Top Ground e/24 Refer to vologe buu-Aer trble fur Ix i�t Hybrid Trunk requvements per radio type and trunk 2 length $RAN LTE LTE FDDITDD A i rscaiel 2 ANTENNA CONFIGURATION NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. m 61 lY tw (C V J 0. C] F- 'V N N S7 n SUPPLEMENTAL SHEET NUMBER: REVISION: R-601 0 MANUFACTURER: .DELTA MODEL: HPL3.05 HP —LARGE POWER CABIN DIMENSKM: 72 x 30 x 34.6 H x W x D WEIGHT: SSO LBS O EQUIPMENT) • CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUTS. DO NOT DRILL THROUGH KNOCKOUTS • CONDUIT MUST BE PROPERLY SECURED TO PREVENT DAMAGE TO CABINETS AND OR CABLING BACK PANEL FOLDS our 31.8" 5.7" 1 6.7' s•• 00 PUNCH THREE 2A' NM FOR r HYBRD 7EJLIB14A7DN Iu-. _:.. fz�njfi CABINET LOWER d' x.a a31" s.3• PLNITH LEFT VIEW GROUNDING NOTE: "CABINET GROUNDING TO USE A SINGLE. f2 BTICW CONDUCTOR, W/ 2—HOLE, 1" C—C. LONG BARREL. WINDOW LUG, IN 3/4" LFNC TO GROUND RING. PLINTH GROUNDING IS NOT REQUIRED." r I(N U FOR FBTETL • GABLE LL LL USED FOR OPS ao m 2` KNOOMH FOR MW (3) PIPC BRE INFENDED FWEIk/EfF U9U FOR AWY « 7f-F AW/CIEM DC POWER TWO HOLE LUO FOR OROUNDIHG OM SOM PLAN VIEW FRONT VIEW BOLT DOWN PATTERN 34857 - HPL3.05 DELTA SITE SUPPORT CABINET SCALE: N.T.S. r KNOCIDUW W/ _BIRD CONDUIT. COIR W OW FOR BATTfiC1r OWE CONOW WSW BE PROPERLY SECURED TU PREYEHW QAApiOE — TWO HOLE LUO FOR OROUNDING (BORN SDEB)- CABMET LOWER r PLM C x• I.rocwouTs FOR Dc AND ca�noN To BA7TER1" CAMEr OOIDUIT WSW BE PROPERLY BECURm RO PftEma DAMAGE — r KNOONOM FOR AC PowER TT) BATTERY CABllET COMUIT WSW BE pflopmy BEICUREI) TO PFCAM DAMM (2) r KNOCKOUTS W/ fmo COIOUIT. LB COf X BODY FOR 3/0 7" WMi III THE 2) 1 i . CONDUfE WSW BE Y IIEC = TO PREYENi QAMAOE RIGHT VIEW NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT �w SUPPLEMENTAL SHEET NUMBER: REVISTON: R-602 0 DO POW ONIM (SHOWN N FW — CABLE mANAImAENT/BIANx l Y CABLE MANAGEMENT/HLANK CABLE MANAIXMIE C/6UU7K. CABLE MAIU MENT/BLANK OPTIONAL EQUIPMENT (SHOWN 01 YELLOW) ETHERNET CAN.EE RACK MOUNT SPD SHELF � e • (SHOWN N guml (IF NEEDED) RE�ERYED FOR HYBRID TERMINAM FSEE ON FMAB am INTERNAL ROUTING (DOOR OPEN) RU SLOTS RACK ASSIGNMENTS BREAKER SHELF RECTIFIER SHELF SHELF 1 DELTA VOLTAGE BOOSTER #1 —2RU 2 3 DELTA VOLTAGE BOOSTER #2-2RU 4 5 CABLE MANAGEMENT 6 AIRSCALE #1 7 8 9 CABLE MANAGEMENT 10 AIRSCALE #2 11 12 13 CABLE MANAGEMENT 14 LEGACY BASEBAND 15 16 17 CABLE MANAGEMENT 18 OPTIONAL EQUIPMENT 19 20 21 FIBER TRAY #2 22 FIBER TRAY #1 23 RACK MOUNT SPD SHELF (IF NEEDED) 24 25 UNUSED/RESERVED 26 FSEE ON FMBA 27 FLOOR SPD SHELF 34867 - HPL3.05 DELTA SITE SUPPORT CABINET SCALE: N.T.S. fib► I'r �_ is-.M�.. :� S 1 11 ■ Elm ■■ ,,.�,LRACK OPTION . y �i11;Ti['IrTirliii II'iil'll[i'•�� I.: '� ;�rlr�rlr��rlri� rrl �nlrr'•�•. MOUNT SPD SHELF FRONT VIEW (DOOR OPEN) NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SUPPLEMENTAL SHEET NUMBER: REVISION: R-603 0 EXIWIIIL C = CC RETURN x I T LOAD EE� 10A 1P >8 WA 1P 1000 9P No ,o Wool - Q DC POWER SYSTEM RElEAYE 3 PWR11010 FOR FXIFJUML OABEE7s (V2/1111113AAM AARN MY COMM xe ALA —RCMVMR SLUM }2 600mm CB 51ot 1 1 3 a 5 1 6 7 1 8 1 9 110111112 13 14 17 0 17 191 19120121122 23124 25 26 27128129 90 31 92 33 34 j5 o A a n 8 z IF o x X rc c Yo qq x � c "matW23 5 6 7 9 9 10 11 11 19 M 15 16 17 I. 1B 19 20 21 22 23 24 25 26 27 28 29 9O 91 92 33 34 95 a c ry o tR a o N x -e (D_3q4486E7 - HPL3.05 DELTA SITE SUPPORT CABINET SCALE: N.T.S. NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SUPPLEMENTAL SHEET NUMBER: REVISION: R-604 0 NOTE: t. ALL CONDUIT AND FITTING ENTRANCES INTO CABINETS AND ENCLOSURES MUST UTILIZE MYERS OR EQUIVALENT HUBS OR SEALING WASHERS TO PREVENT WATER ENTRY/SEEPAGE INTO CABINETS AND ENCLOSURES. 2. (LIQUIDFLEX) FLEXIBLE METALLIC CONDUIT (LFMC) & ASSOCIATED FITTINGS CAN BE USED AS NEEDED BUT ONLY FOR TIGHT CONDUIT BENDS AND RUNS SUBJECT TO UL AND NEC LIMITATIONS. 6' MAX PER CONDUIT RUN. 3. POWER CONDUIT BODY ATTACHED WITH SHORT NIPPLE AND SEALING WASHER INSIDE & OUT. (FOR DOOR HOOD CLEARANCE) 4. PULLING ELBOWS MAY BE USED IN LIEU OF A CONDUIT BODIES WHEN CLEARANCE IS LIMITED. 5. (DO NOT USE CHASE NIPPLES) CONDUIT SHOULD HAVE SEALING WASHERS INSIDE AND OUT w/ LOCK NUT AND CAP. BACK PANEL FOLDS OUT O ooo ° 0 2' KNOCKOUT FOR FIBER t OPS 2' LL USED FOR OPS CABLE 2' KNOCKOUT FOR MW FUTURE HPL3 PUNCH THREE 2.5' HOLES FOR 2' r HYBRID TERMINATION I (lulu F� ' . �:-LG1}D1Y 1 901 I (3) 1' KNOCKOUTS ARE INTENDED I FOR PPC ALARMING. FTBM/ETHERNET FOR MV k MV/CIENA DC POWER CABINET LOWER 6' PUNCH I TWO HOLE _-- ---- GROUNDING (BOTH SIDES) DELTA SITE 9 34867 - HPL3.05 DELTA SITE SUPPORT CABINET SCALE: N.T.S. DELTA LB3 BATTERY CABINET 3' KNOCKOUT w/ RIGID CONPUfT, CONDUIT BODY FOR DATTFRY CABLE CONDUIT MUST BE PROPERLY SECURED TO PREVENT DAMAGE 3 2 KNOCKOUTS FOR DC AND NET CONNECRON TO BATTEFFY CABINET CONDUIT MUST 13E PROPERLY SECURED TO PREVENT DAMAGE 2' KNOCKOUTS FOR AC POWEF DC CABINET FOR HEATER COW MUST BE PROPERLY SECURED PREVENT DAMAGE (2) 3" KNOCKOUTS W/ R1GID CONDUIT. LS CONDUIT BODY FOF 3/0 THHN WIRE THROUGH THE (; 1/2' . CONDUIT MUST BE PROPERLY SECURED TO PREVENT DAMAGE GROUNDING (BOTH SIDES) NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT, m e m 91 a U J J n. c� r a N N s SUPPLEMENTAL SHEET NUMBER: REVISION: R-605 0 46MP71CTUTM DELTA MODEL LB3 BATTERY SUPPORT CABINET DIMENSIONS. 72 x 35' (N. -x_W x_D WEK*IT: 500 LB5 YYITHOII� EpUPMEJ� NOTE • CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUTS. DO NOT DRILL THROUGH KNOCKOUTS • CONDUIT MUST BE PROPERLY SECURED TO PREVENT DAMAGE TO CABINETS AND OR CABLING ET*wv COINII is BATrucf Clillow CxOLR r lb0o CO !uu LL T EIODY p1�11EA1 C4fE E -VW DAMAK N PROPflILY eEONIFL I r IOIOCHMM FOR AC POWER TO DC CNEW FOR HEMM IDLE LLN FOR DIHO owm 3m) LEFT VIEW GROUNDING NOTE "CABINET GROUNDING TO USE A SING, #2 ff= CONDUCTOR, W/ 2—HOLE, T' C—C, LONG BARREL, WINDOIN LUG, IN 3/4' LFNC TO GROUND RING. PLINTH GROUNDING IS NOT REQUIRED." PLAN VIEW FRONT VIEW BOLT DOWN PATTERN 0 DELTA L133 BATTERY CABINET SPECIFICATIONS SCALE: N.T.S. TWO HOLE LUG FO fyerrr I rY fr RIGHT VIEW NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT, U W N W P N R_P x a U 0. [7 H d a P L] SUPPLEMENTAL SHEET NUMBER: REVISION: R-606 0 MANUFACTURER: NOKIA MODEL: ASIL CONTROLLER CARD (474767A) DIMENSIONS: 1.9" X 8 62" X 14.84" WEIGHT: R.6 LBS SAC (HDMI) (HDMI) GROUND (DUALOE 2x M6)_I soul (I "All} DC IN — (CLAMPS) EIF1 (SFP) EIF2 (SFP) EIF3 (SFP) MANUFACTURER: NOKIA MODEL: ABIA WEIGHT: 4.6 LBS DIMENSIONS: &6"X142".X1.1" MANUFACTURER: NOKIA MODEL: ARIL WEIGHT: 4.4 LBS DIMENSIONS! 0.61X1d21X1.1" I SFP28 S-RF1 S-RF2 RF172- RF3 RF4 RF5 RF6 a oo a $ Q � o$oaoaoeoag oggo g � RESET LMP1E11F4 OOOOO tl0 ❑❑ O❑ OO OO O❑ OO 00 00 O❑ ❑ ® S-RF1 OSFP28 S-RF2 i SF WIT SEI2 (OSFP) SE11 (OSFP) WITHIN AMIA RACK v^ �y ,� ASIL DETAIL 2 ABIA DETAIL SCALE: N.T.S. SCALE: N T.S. MANUFACTURER: NOKIA MODEL: 3HE15548M GNSS RECEIVER DIMENSIONS: 17.25" x 10" x 1.75" MANAGEMENT WEIGHT: 10.5 LBS FULLY EQUIPPED) SFP28/SFP+ SFP/SFP+ 10 Gbpe 25Gbpe PORTS DC PSU DC PSU PORTS 1-24 25-32 �1 �� wwws�lw�l ewrrwwwwlIwwwNBC _ � ■rrE -' GROUNDING CHASSIS, USE TWO HOLE LUG, DESIGNED FOR #8 AWG BURNDY (YAZBC2TC1O45) NOKIA PIN# 52-1178-01 QSFP28 10OGBPS PORTS 33-34 USB CONSOLE 0 REAR VIEW 17.25" - 10" ` ® I SIDE VIEW 1.75" 34097 - NOKIA 7250 IXR-e ROUTER w/ GNSS SCALE: N.T.S. 3 ABIL DETAIL SCALE: N.T.S MANUFACTURER: NOKIA MODEL: AMIA WEIGHT: 112 LBS (UNIT ONLY) DIMENSIONS: 5.1X75.7"X17.6" AMIA DETAIL SCALE: N T S NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BYREOUEST OF CUSTOMER WITHOUT EDIT. rn Q 0. Y r d SUPPLEMENTAL SHEET NUMBER: REVISION: R-607 0 VFat. � - f07.Ot xAm_ gin K .- YNMlEAO EO1! 3 ■ MMMfI- IM %14 I- Ewa PARAMETER a WEICHT 1-HEAR FOOT i70UN U 7,bS FIBER RFS 6x24 FILLER PARAMETER VALUE NOMINAL DIAMETER INCHES 1.8 CROSS-SECTION AREA SQUARE INCHES 2.84 JACKET COLOR BLACK WEIGHT/LINEAR FOOT POUNDS 2.48 SINGLE MODE AWANCE 6x24 X48 /� FLAME RESISTANT ` FILLERS 1 V f''ARAUE7E13 4 AWC COPPER CORRUGATED RdAL pWIA£'f('M INr.'HES i1..79 ,7g CONDUCTOR X12 COPPER ARMOR C9D5S-SfCTkDI�.CAREA � 9UA RE IN::IdE5 Bw3< IP CORD PVC OUTER JACKET 1 4 I Y'EIGHT LIh,E41{ F't1DT YUUli:75 2.65 37l1' 1&2r Mw CONNECTUIRS .-0 . • a • • •• a •_• } 39179 - COMMSCOPE FFW-65C-R2N23 SCALE: N.T.S 70w U� Molt px loft nEIG10 I d1 m • 2634' �(,y( 2Q61' vw 4F=ffgaup 4.72';71 _ w DC 2- M GROUND; MOHA111O1M FORIs 1& 2d16� POWER A p -28 34577 - AHFII - 4T4R DUAL -BAND -RADIO SCALE: N T.S - NETWORK WIRELESS SOLUTIONS 604 12f iG PA((AUETEH VALIJE NOMINAL DIAME)" 14Ci{ES 1.76 CROSS-SECTION AREA SQUARE INCHES 2.43 JACKET COLOR HIAi J( WDGHT/LINEAR FOOT FOI1N')S 2.77 COMMSCOPE fix24 I ' STIFFENER TUBS - r; (6x24) HYBRID TRUNK CROSS SECTION q - I 0.5" x 11" SCUE N.T.S. 111" . 17' SCALE N.7.S. I I PA. VIETER VALUE NOMINAL ) R INCHES t.62 CROSS-SECTION AREA SQUARE INCHES 2-04� .IACKET COLOR HLACK WER T/LINEAR F= P(R "i 2.39 RIFE CORD PVC OUTER JACKET e HURER+SUH:VER fix24 (fix24) HYBRID TRUNK CROSS SECTION !/1 6.5' . 1 i' 6041E 11.T.3- 11' . Il- 5CA N.T.'3. C.6N V.nd.r C.bb Typ. NomIrW DD In. C.S.Aw .9. In. WNyht walght ..T.p Bn.k.ut MAX ENT17LEMENT lice 2A 6 AWG 28' t9 2 R6' ea bl. long Ih. 1109 P.nd.nl ot$dkw) 01 MW"-. in. AIIIAnce 6k2a 6AWG 146 167 I21 1636.9.30.5.79( Jk1152.15) N6mkW DDOO LS5 Lbr+nrO 6 46AW0 1.nS 1.09 i-7L 1937. 1D,01 xS 12 23 1in9A7 C-5, A- wtk 1.04 WWI 0,124 (,AWC 1.49 112 5-61 15.96 x 1I1.20 k 3.21 "An 162AP Wal ht b.JR L.71 1.'( 0YZ46AWa 1.46 L07 7-65 19.37. SD.93 k 5.12 wJM 2D93B) wnd.m w/l 1 235A7 4 ftwG S1JO' W 411w cob% le"7111a AIII.- tW4 4AW0 -1.0 154 12,48 L636 r930. 5-74 f Jn IS2- Namba w OMJ 1a Lien 6-44AW0 L76 Z4 12,41 0.37. 10R3 . 5. 12 lnJ1n 20S.W C.6.Aro.. Jvn 254 IVWS cW44AWG 1.1.79 231 12,66 16.95x 10.20. 3.2 L(.. Jln J42.69 246 "him 6t.244AWG In 12,3 TAR t9.37r3D.63k5-32 aiJina09.78 IY.16AR pn rasn7 11.24 0.24 Cwdtter 0r.ak..1- OD . u."pth (I".) Alu" 61744A WO Lu 2,54 7All 3.11. 9.45(c.. Ala. 7.60) NOmh•I OD On.I 2 2L-1k . br/44A 1.76 2-43 739 260. 9117-A-6.64 C.S. Ain. fig 3.fa HR8 m-14AW0 142 204 2.39 392. 9.26 e.. AI..1%A6 Ww911t nb./N] 2A5 NWS OM 4AY90 11.7v 2.3) 2.65 2.99. IL12 ...A1r7.D2) IC.nkler(wlln] 1L46 Ff0 6Q441(WG 2 3-13 I 2S5 2Ei6. 9.77 1,. A"1.6.S1 6x24 HYBRID TRUNK ENTITLEMENT INFORMATION 13 B.S- x I1- SCALE N.T11- . 1T SCALE N_T. S_ S. 3 HYBRID TRUNK INFORMATION 6X24 SCALE: N.T.S. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SUPPLEMENTAL SHEET NUMBER: R-608 RENT SI ON: 0 ^MERICJLNTGWER* C O R P O R A T I O N Mount Type : 7 ft V-Frame ATC Asset Name ; SEELEY WI ATC Asset Number : 311285 Engineering Number : 14907585_C8_01 Mount Elevation : 234 ft Proposed Carrier : T-Mobile Carrier Site Name : Hayward-ATC 311285 Carrier Site Number A1N0960A Site Location 13063 West Old 00 Road Hayward, WI 54843-6324 46.1111,-91.3482 County Sawyer Date October 31, 2024 Max Usage 54% Analysis Result Pass Prepared By: Munir Fleurizard Structural Engineer AL'aiQ J.w+ia� Digitally signed 6y Willlam William Garrett Dal e:2024,103116.41:23 o4'olr COA: 4069-11 ATC Tower Services 1 Fenton Main, Suite 300 - Cary, NC 27511 - 919-468.0112 Office- 919-466.5414 Fax - www americantower.com � MOUNT ANALYSIS Eng. Number 14907585_C8_01 Aok October 31, 2024 AM@wICANTOWEw' Page 3 Introduction The purpose of this report is to summarize results of the mount analysis performed for T-Mobile at 234 ft. Supporting Documents Specifications Sheet: ALT 211611-7, dated October 27, 2016 Radio Frequency Data Sheet: RFDS ID #A1N0960A, dated October 4, 2024 Reference Photos: Site photos from 2021 Analysis This mount was analyzed using American Tower Corporation's Mount Analysis Program and RISA-31D Basic Wind Speed: 106 mph (3-Second Gust) Basic Wind Speed w/ Ice: 50 mph (3-Second Gust) w/ 1.50" radial ice concurrent Codes: ANSI/TIA-222-H Exposure Category: B Risk Category: II Topographic Factor Procedure: Method 2 Feature: Flat Crest Height (H): 0 ft Crest Length (L): 0 ft Spectral Response: Ss = 0.041, S1= 0.018 Site Class: D - Stiff Soil - Default Live Loads: Lm = 500 Ibs, Lv = 250 Ibs -Live Load(s) reduction Is confirmed to either not govern or not be applicable Conclusion Based on the analysis results, the antenna mount meets the requirements per the applicable codes listed above. The mount can support the equipment as described in this report. If you have any questions or require additional information, please reach out to your American Tower contact. If you do not have an American Tower contact and have an Engineering question, please contact MountAnalysis@americantower.com. Please include the American Tower site name, site number, and engineering number in the subject line for any questions. ATC Tower Sewlces -I Fenton Main, Suite 300 - Cary, NC 27511. 919A69.0112 Office - 919.4665414 Fax - www.americantower,com NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. PLEASE REFERENCE THE MOUNT ANALYSIS REPORT FOR COMPLETE MOUNT ANALYSIS CALCULATIONS AND DETAILS. SUPPLEMENTAL PAGES INCLUDED IN THE CONSTRUCTION DRAWINGS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO VERIFY THEY HAVE THE MOST RECENT MOUNT ANALYSIS PRIOR TO CONTRUCTION. m a Il° a Q t ne pa C] SUPPLEMENTAL SHEET NUMBER: REVISION: R-609 0