HomeMy WebLinkAbout006-339-24-2401-LUP-2024-472REGIONAL MAP N T-S �0
I—ftm— 1
Lb
Zt. - SITE
P4 LOCATION
Park Falls
■
verizon%
1701 GOLF ROAD, TOWER 2, SUITE 400
ROLLING MEADOWS, ILLINOIS 60008
PHONE: (847) 619-5397 FAX: (847) 706-7415
MDG LOCATION NUMBER: 5000898289
SITE NAME: W12 NFORK RSW
404W STATE HWY 70 c"'•r
ijf r,
4N
MEMO[ PARK FALLS, WI 54552
"Call 3 Work Days
Before You Dig!
mLM rtic pn
AM ANA 1A14I u lIn
OTHER UT UTIES NOT INCLUDED IN DIGGERS HOTLINE AND LOLL UTILITY
DISTRICTS AND COMPANIES SHALL ALSO BE NOTIFIED
PROJECT TYPE
OCCUPANCY
' SITE ADDRESS
LATITUDE:
LONGITUDE:
TOWER OWNER:
I I APPLICANT:
I
PROJECT INFORMATION
PROPOSED ANTENNA MODIFICATION ON AN
EXISTING WIRELESS SITE
UNINHABITED
404W STATE HWY 70
PARK FALLS, WI 54552
45" 50' 52.03" N (APPROXIMATE)
90" 41' 32,23" W (APPROXIMATE)
TOWERNORTH DEVELOPMENT, LLC
750 W CENTER STREET, SUITE 301
W BRIDGEWATER. MA 02379
VERIZON WIRELESS
1701 GOLF ROAD, TOWER 2, SUITE 400
ROLLING MEADOWS, IL 60008
I REAL ESTATE MANAGER: , OCTAVIO HERRERA (847) 6194142 1
SHEETINDEX
SHEET
DESCRIPTION
T-1
TITLE SHEET
C-1
SITE LAYOUT
ANT-1
SITE ELEVATION
ANT-2
ANTENNA AND ICE BRIDGE DETAILS
E-1
GROUNDING DETAIL
SPA
GENERALNOTES
SP-2
GENERAL NOTES
� m
0
N
0 F � ma's O�0Wo
( LLrnO�"
:2
c'wwm
��w�
0 Z 0 �<
¢
~ :J
O
CC
I
3S —
c�
Hou
W o��
� Y o
4.4
I
50000898289
MDG #
WI2
NKORK RSW
404W STATE HWY 70
REVISION PARK FALLS, WI 5455;
DRAWN BY AC
CHECKED BY PF
DATE 07/12/21
PROJECT# 194-16E
SHEET TITLE
TITLE SHEET
SHEET NUMBER
T-1
FULL SCALE: 22"x34" I HALF SCALE: 11"x17"
` - EXISTING 100' X 100'
1 TOWER DEVELOPMENT p
I LEASE AREA
I h
PROPOSED (1) OMT @ 210' H
/ (121"x2.87"x9.69",11.0LB,)
I PROPOSED (1) RFS HBF058-6CS2S2
HYBRIFLEX RRH HYBRID 2X2 CABLE
PROPOSED (2) UBT-S ODUTO'S @210' / LB) ROUTED ON ICE BRIDGE TO
A.G.L. / ff TOWER
PROPOSED LESSEE MICROWAVE 0 B 10 20'
ANTENNA AND MICROWAVE RADIOS 22"� 34" PRINT ISTHE FULL SCALE
TO BE INSTALLED ON EXISTING SELF FORMAT ANYSIZEOTHERTHAN
SUPPORT TOWER. SEE ANT-1 & ANT-2 I THAT IS AT REDUCEDSCALE
EXISTING 280' HIGH
SELF-SUPPORT TOWER
1 ` )
EXISTING LESSEE
J
/ ICE BRIDGE
J / �
EXISTING 30' X 12'
LESSEE LEASE AREA
EXISTING f
(GRAVEL • EXISTING LESSEE
COMPOUND N\ JJCONCRETE PAD NTH
I EQUIPMENT CABINETS
\ \ >r
/
' v / J✓
I
I \ J
I J
/
EXISTING /• \\ \\
( GRAVEL
GCCESS DRIVE / \\
EXISTING
/ � ✓/ UTILITY H-FRAMES
/ EXISTING 75' X 75'
CHAIN -LINK FENCE
COMPOUND
>UBLE
EXISTING DSWING GATE
THIS SITE PLAN WAS BASED OFF ON SITE LAYOUT
INFORMATION PROVIDED BY THE CLIENT.
NO SITE VISIT WAS PERFORMED PRIOR
TO THIS PROJECT
m
_ o
0
omrn�
LLNO�r
-
ownC7�'w W
4 0 zx
�Oz0LL
0a
50000898289
MDG #
W12
NKORK RSW
404W STATE HWY 70
PARK FALLS, WI 54552
DRAWN BY AC
CHECKEDBY PP
DATE 07/1224
PROJECT #: 194-168
I
SHEET TITLE
SITE LAYOUT
SHEET NUMBER
C-1
NOTE:
THIS DRAWING IS FOR EXHIBIT
AND LAYOUT PURPOSES ONLY
PLEASE REFER TO STRUCTURAL
ANALYSIS PROVIDED BY
OTHERS.
4� d
o +I
N Q
WOf
N
7
D 3
/r O
~l ~
LL 0
O
1-a
1:O
O O
w r
= W
J 0
J Z
F
W
O o
EXISTING
N
.� EXISTING
_ LIGHTING ROD
MICROWAVE CONFIGURATION
DISH MFR
DISH MODEL#
OTY
AZIMUTH
CENTER
CABLE
CABLE
(DEG)
LINE
MODEL
CITY
RFS ABF05B -
COMMSCOPE
USX8-6W
1
97.90"
210'
6CS2S2 HYBRIFLEX
1
RRH HYBRID
EXISTING LESSEE ANTENNAS
AND ANCILLARY EQUIPMENT
PROPOSED (1) OMT @ 210'
(12. 1" x 2.87" x 9.69", 11.0 LB.)
PROPOSED (1) USX8-6W MW
ANTENNA @ 210' A.G.L.
(95.1" 0 x 51.1", 432.10 LB)
PROPOSED (2) NOKIA WAVENCE UBTS
W/AIM-S ACM MW RADIO @ 210' A.G.L.
(EA. 105'X &8" X 5.0" 11.9113)
EXISTING
SELF-SUPPORT TOWER
R PROPOSED(1)RFSBRID 2X2 CABL
- HYBRIFLEX RRH HYBRID 2X2 CABLE
(45 LB) ROUTED ON ICE BRIDGE TO
TOWER
r1 SOUTHWEST ELEVATION
SCALE: 1/16" = T-0" t
EXISTING LESSEE
EQUIPMENT SHELTER
EXISTING CHAIN -LINK
I FENCE (PARTIALLY SHOWN
FOR CLARITY)
50000898289
MDG #
W12
NKORK RSW
404W STATE HWY 70
PARK FALLS, WI 54552
DRAWN BY AC
CHECKED BY PP
DATE: 07/12/24
PROJECT# 184-168
SHEET TITLE
SITE
ELEVATION
SHEET NUMBER
ANTml
FULL SCALE PRINT IS ON 22"x34" MEDIA
HALF SCALE PRINT IS ON 11"07" MEDIA
USX8-6W
Antenna Dimensions and Mounting Information
USX8
Dimensions In Inches (mm)
-I
Antenna sue. III A B C t D1 02 E F G
rmr
B + 95.1 6.0 22.5 14.1 V4, r 51.1 ' 12.1 10.3
[7 6 L(2416), (203) (572) (357) (MI _(1298), (306) _ (262)
MICROWAVE SPECIFICATIONS
N.T.S
PROPOSED MICROWAVE ANTENNA
TO BE MOUNTED TO TOWER PER
MANUFACTURER'S SPECIFICATIONS
AND PER STRUCTURAL ANALYSIS
UNIVERSAL LEG
PIPE MOUNT
2 ANTENNA MOUNTING DETAIL
N.T.S.
GALV. STL, GRIP STRUT-
24" MIN. 12 GA CHANNEL
W/ 1/2" 0 BOLTS TO
SUPPORT BRACKET
ASTM A325 GALV STEEL:--
1/2 " 0 x6" LONG (FULL
THREAD W/ WASHER AND
LOCK WASHER BOTH SIDES)
INSTALLED BELOW THE ICE
BRIDGE IN 5/8" 0 HOLE
DRILLED IN SUPPORT PIPE
(COLD GALV. DRILLED HOLE}
3-1/2" O.D. SCH.'
40 GALVANIZED
STEEL PIPE
�+1
ROHN VY WAVEGUIDE BRIDGE
(GRIP STRUT) OR APPROVED
EQUAL CUT TO FIT
GALVANIZED STEEL'SNAP-IN'
BARS 3'-0" O.C. SUSPENDED WITH
3/8" 0 GALVANIZED ALL THREAD
ROD. EXTEND AS NEEDED
FOR CABLE HANGER
REQUIREMENTS, SEE TABLE
NOTES:
1. ICE BRIDGE POST SHOULD BE STAGGERED
ON EITHER SIDE OF ICE BRIDGE FOR EXTRA
STABILITY
2. ANY SPLICES OR CANTILEVERED SECTIONS
OF THE ICE BRIDGE SHALL BE LOCATED
WITHIN 2'-0" OF A SUPPORT POST.
NOMINAL
CABLE TYPE
CABLE WAVE CABLE
CABLE SIZE
NUMBER
HANGER TYPE NUMBER
1 - 5/B..
810920-001
915594
915594
1 -1/4"
810916-001
920989-004-BOLTAN
7/6"
810921-001
915660
VFRGIN SOIL OR COMPACTED
BACKFILL WITH A MINIMUM
BEARING CAPACITY OF 2,000
PSF. TYP.
I WO CONCRETE PIER. (4) #4
GR. 60 REBAR W/12" 0 CIRCLE
TIES AT 12'. O.0 CONCRETE TO
BE 4000 PSI @ 28 DAYS W/6%
(±1%) ENTRAINED AIR
ICE BRIDGE DETAIL
NTS
7 m I
O m O^1 N
�
N0_ Ls
u�O^�
WCm
■ONQm�
O W v
LL� O'._
�$ZO<
�Oo
O
Ell
��
W IB
Y
U
-
m
a
a
S
$
CO)
O
p
w
5
a
w
LL
0_
a
o
rc
U
0
n
LL
u
W
�
O
i
i
o
50000898289
MDG #
WI2
NKORK RSW
404W STATE HWY 70
PARK FALLS, WI 54552
DRAWN BY: AC
CHECKED BY: PP
DATE: 0711224
PROJECT # 194-168
SHEET TITLE
ANTENNA &
ICE BRIDGE DETAILS
SHEETNUMBER
ANT=2
ANTENNA SECTOR "1" ANTENNA SECTOR "2" ANTENNA SECTOR "3"
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
ANTENNA
ANTENNA PIPE
ANTENNA
ANTENNA PIPE
ANTENNA
ANTENNA PIPE
COAX GRND
SUPPORTS
COAX GRND
SUPPORTS
COAX GRND
SUPPORTS
KIT CABLE
KIT CABLE
KIT CABLE
till-! EX. #2 GND
f_ I
I
{
I
I
l
EXISTING SECTOR GROUND BAR
BOLTED CONNECTION —
DIRECT TO TOWER STEEL
TOPOFTOWER
PROPOSED PROPOSED
MICROWAVE CABLE
DISH & MOUNT GRND KIT
PROPOSED
#2 GND
TOP OF TOWER GROUNDING SCHEMATIC
SECTORS 1, 2, & 3 & GPS
EXIMNG #2 GND. _ EX_IS_TIN_G_G_R_O_UND_R_ING__
LEADS TO TOWER
EX. ANTENNA ��\
STEEL COAX GND. KIT
CABLE � �- -� EXISTING FENCE CORNERS
EXISTING EXISTING EXISTING EXISTING j
92 GND, E7fI5TING GNI3. I I CABINET CABINET CABINET I EXISTING TELCO H-FRAME
#2 I *�
' +� EXISTING AC SERVICE
EX. TOWER I EXISTING MASTER ELECTRODE TOWER I j GROUND BAR AT
HOTTDM GND. BAR
11 I \ I EQUIPMENT SHELTER �
#2 GND-
ti rr EXISTING #2 GND.
EXISTING #2 GND. SOLID
TINNED BURRIED RING
I EXISTING #2 GND
EXISTING TOWER GROUND EXISTING EXISTING
RING ICE BRIDGE/ GPS
H-FRAME ANTENNA
POSTS
GRADE LEVEL GROUNDING SCHEMATIC
0 GROUNDING SCHEMATICS
N.T.S.
g a r
W 11
50000898289
MDG #
W12
NKORK RSW
404W STATE HWY 70
PARK FALLS, WI 54552
DRAWN BY: AC
CHECKED BY: PP
DATE: 07112/24
PROJECT #. 184-166
SHEET TITLE
GROUNDING
DETAIL
SHEET NUMBER
E-1
GENERAL
THE CONSTRUCTION DOCUMENT DRAWINGS ARE INTERRELATED WHEN
PERFORMING THE WORK, EACH CONTRACTOR MUST REFER TO ALL DRAWINGS
COORDINATION 15 THL RESPONSIBILITI' OF THE GENERAL CONTRACTOR
PIV1510N is I;L_NLHAL RCQUIRMENT�
SkC.Tl0 _giZr)Q - EROJECT r: USE(1U
PART I - GENERA_I
A OBTAIN AND SUBMIT RELEASES ENABLING THE OWNER UNRESTRICTED USE OF THE WORK
AND ACCESS TO SERVICES AND UTILITIES' INCLUDE OCCUPANCY PERMITS, OPERATING
CERTIFICATES AND SIMILAR RELEASES.
B. SUBMIT RECORD DRAWINGS, DAMAGE OR SETTLEMENT SURVEY, PROPERTY SURVEY, AND
SIMILAR FINAL RECORD INFORMATION
C COMPLETE FINAL CLAN UP REQUIREMENTS, INCLUDING TOUCH-UP PAINTING. TOUCH UP
AND OTHERWISE REPAIR AND RESTORE MARRED EXPOSED FINISHES
- I clt
PAttT.2 P NA]`_
ATi(iT�
1 COMPLETE THE FOLLOWING CLEA
NING OPERATIONS BEFORE REQUESTING INSPECTION
FOR CERTIFICATION OF COMPLETION.
N
A. CLAN THE PROJECT SITE, YARD AND GROUNDS, IN AREAS DISTURBED BY
CONSTRUCTION ACTIVITIES, INCLUDING LANDSCAPE DEVELOPMENT AREAS, OF
RUBBISH, WASTE MATERIALS, LITTER AND FOREIGN SUBSTANCES SWEEP PAVED
AREAS BROOM CLEAN, REMOVE PETRO-CHEMICAL SPILLS, STAINS AND OTHER
FOREIGN DEPOSITS RAKE GROUNDS THAT ARE NEITHER PANTED NOR PAVED,
TO A SMOOTH EVEN -TEXTURED SURFACE
B REMOVE TOOLS, CONSTRUCTION EQUIPMENT, MACHINERY AND SURPLUS MATERIAL
FROM THE SITE.
C REMOVE SNOW AND ICE TO PROVIDE SAFE ACCESS TO THE SITE AND EQUIPMENT
ENCLOSURE.
D CLAN EXPOSED EXTERIOR AND INTERIOR HARD -SURFACED FINISHES TO A DIRT -
FREE CONDITION, FREE OF STAINS, FILMS AND SIMILAR FOREIGN SUBSTANCES.
AVOID DISTURBING NATURAL WEATHERING OF EXTERIOR SURFACES
E. REMOVE DEBRIS FROM LIMITED ACCESS SPACES, INCLUDING ROOFS, EQUIPMENT
ENCLOSURE, MANHOLES, AND SIMILAR SPACES.
F. REMOVE LABELS THAT ARE NOT PERMANENT LABELS.
G. TOUCH-UP AND OTHERWISE REPAIR AND RESTORE MARRED EXPOSED FINISHES
AND SURFACES. REPLACE FINISHES AND SURFACES THAT CAN NOT BE
SATISFACTORILY REPAIRED OR RESTORED, OR THAT SHOW EVIDENCE OF REPAIR
OR RESTORATION DO NOT PAINT OVER "UL" AND SIMILAR LABELS, INCLUDING
ELECTRICAL NAME PLATES-
H. LEAVE THE PROJECT CLAN AND READY FOR
OCCUPANCY.
I. DUST -OFF ALL EQUIPMENT, INCLUDING BATTERY PACKS, WITHIN EQUIPMENT
ENCLOSURE
J WASH AND WAX FLOOR WITHIN EQUIPMENT ENCLOSURE.
2. REMOVAL OF PROTECTION: REMOVE TEMPORARY PROTECTION AND FACILITIES
INSTALLED DURING CONSTRUCTION TO PROTECT PREVIOUSLY COMPLETED
INSTALLATIONS DURING THE REMAINDER OF THE CONSTRUCTION PERIOD,
DIVISION 2: SITE WORK
.SkT:. Tr17Al _{1a7D0 - EARTHVIL]RK AND DRAINAGE
PART I - GENERAL
1. WORK INCLUDED: SEE SITE PLAN
2, DESCRIPTIONS
ACCESS DRIVE W/ TURNAROUND AREA, LASE AREA, AND IF APPLICABLE
UNDERGROUND UTILITY EASEMENTS ARE TO BE CONSTRUCTED TO PROVIDE
A WELL DRAINED, EASILY MAINTAINED, EVEN SURFACE FOR MATERIAL AND
EQUIPMENT DELIVERIES AND MAINTENANCE PERSONNEL ACCESS,
3. QUALITY ASSURANCE
A APPLY SOIL STERILIZER IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS
(AS NEEDED).
B APPLY AND MAINTAIN GRASS SEED AS RECOMMENDED BY THE SEED PRODUCER
(IF REQUIRED).
C PLACE AND MAINTAIN VEGETATION LANDSCAPING, IF INCLUDED WITHIN THE CONTRACT,
AS RECOMMENDED BY NURSERY INDUSTRY STANDARDS
4. SEQUENCING
A CONFIRM SURVEY STAKES AND SET ELEVATION STAKES PRIOR TO ANY CONSTRUCTION.
B. COMPLETELY GRUB THE ACCESS DRIVE W/ TURNAROUND, UNDERGROUND UTILITY
EASEMENTS, (IF APPLICABLE) AND LASE AREA PRIOR TO FOUNDATION CONSTRUCTION,
PLACEMENT OF BACKFILL AND SUB -BASE MATERIAL
C. CONSTRUCT TEMPORARY CONSTRUCTION AREA ALONG ACCESS DRIVE.
D BRING THE LEASE AREA AND ACCESS DRIVE W/ TURNAROUND
TO BASE COURSE ELEVATION PRIOR TO INSTALLING FOUNDATION,
E APPLY SOIL STERILIZER PRIOR TO PLACING BASE MATERIALS.
F. GRADE, SEED, FERRLI?T. AND MULCH ALL ANFAS 0
6TlRi8ED BY pr1N67ROWTION
ETIURY EA8�M)lNbMll'l AFTER SWUNG
LEASEUDING AR A ANDACCESSD ❑ UNDERGROUND
DDRLVE W/ TURNAROUND RAM COURSE ELEVATION,
WATER TO ENSURE GROWTH,
G. REMOVE GRAVEL FROM TEMPORARY CONSTRUCTION ZONE TO AN AUTHORIZED
AREA OR AS DIRECTED BY PROJECT MANAGER,
H AFTER APPLICATIONS OF FINAL SURFACES, APPLY SOIL STERILIZER TO STONE
SURFACES.
5 SUBMITTALS
A BEFORE CONSTRUCTION
IF LANDSCAPING IS APPLICABLE TO THE CONTRACT, SUBMIT TWO COPIES OF THE
LANDSCAPE PLAN UNDER NURSERY LETTERHEAD, IF A LANDSCAPE ALLOWANCE WAS
INCLUDED IN THE CONTRACT, PROVIDE AN ITEMIZED LISTING OF PROPOSED COSTS
ON NURSERY LETTERHEAD (REFER TO PLANS FOR LANDSCAPING REQUIREMENTS).
B AFTER CONSTRUCTION
1 MANUFACTURER'S DESCRIPTION OF PRODUCT AND WARRANTY STATEMENT ON
SOIL STERILIZED.
2 MANUFACTURER'S DESCRIPTION OF PRODUCT ON GRASS SEED AND FERTILIZER
3 LANDSCAPING WARRANTY STATEMENT.
6 WARRANTY
A IN ADDITION TO THE WARRANTY ON ALL CONSTRUCTION COVERED IN THE
CONTRACT DOCUMENTS, THE CONTRACTOR SHALL REPAIR ALL DAMAGE AND
RESTORE AREA AS CLOSE TO ORIGINAL CONDITION AS POSSIBLE AT SITE
AND SURROUNDINGS,
B SOIL STERILIZATION APPLICATION TO GUARANTEE VEGETATION FREE ROAD
AND SITE AREAS FOR ONE YEAR FROM DATE OF FINAL INSPECTION.
G DISTURBED AREAS WILL REFLECT GROWTH OF NEW GRASS COVER PRIOR TO
FINAL INSPECTION,
D LANDSCAPING, IF INCLUDED WITHIN THE SCOPE OF THE CONTRACT, WILL BE
GUARANTEED FOR ONE YEAR FROM DATE OF FINAL INSPECTION.
PAP - P OR DVG15
1 MATERIALS
A SOIL STERILIZER SHALL BE EPA -REGISTERED, PRE -EMERGENCE LIQUID:
TOTAL KILL PHASAR CORPORATION
PRODUCT 910 P 0 BOX 5123
EPA 10292-7 DEARBORN, MI 48128
(313) 563-8000
AMPUSII HERBICIDE FRAMAR INDUSTRIAL PRODUCTS
EPA REGISTERED 1435 MORRIS AVE.
UNION, NJ 07093
(800) 526-4924
B ROAD AND SITE MATERIALS SHALL CONFORM TO IDOT SPECIFICATIONS FILL
MATERIAL (UNLESS OTHERWISE NOTED) - ACCEPTABLE SELECT FILL SHALL
BE IN ACCORDANCE WITH STATE DEPARTMENT OF HIGHWAY AND TRANSPORTATION
STANDARD SPECIFICATIONS.
C SOIL STABILIZER FABRIC SHALL BE MIRAFI - 50OX.
PART 9 - 1SXECUI'bN
1 INSPECTIONS
LOCAL BUILDING INSPECTORS SHALL BE NOTIFIED NO LESS THAN 48 HOURS IN
ADVANCE OF CONCRETE POURS, UNLESS OTHERWISE SPECIFIED BY JURISDICTION,
2. PREPARATION
TREES, BRUSH AND DEBRIS FROM LASE AREA, ACCESS DRIVE W A CLEAR REE / TURN-
AROUND AND UNDER GROUND UTILITY EASEMENTS AS REQUIRED FOR CONSTRUCTION
9. PRIOR TO OTHER EXCAVATION AND CONSTRUCTION, GRUB ORGANIC
MATERIAL TO A MINIMUM OF SIX INCHES (6`) BELOW GRADE
C UNLESS OTHERWISE INSTRUCTED BY LESSEE, TRANSPORT ALL REMOVED
TREES, BRUSH AND DEBRIS FROM THE PROPERTY TO AN AUTHORIZED LANDFILL
D PRIOR TO PLACEMENT OF FILL OR BASE MATERIALS, ROLL THE SOIL
E WHERE UNSTABLE SOIL CONDITIONS ARE ENCOUNTERED, LINE THE AREAS
WITH STABILIZER MAT PRIOR TO PLACEMENT OF FILL OR BASE MATERIAL
3. INSTALLATION
A GRADE OR FILL THE LEASE AREA AND ACCESS DRIVE W/ TURNAROUND
AS REQUIRED IN ORDER THAT UPON DISTRIBUTION OF SPOILS,
RESULTING FROM EXCAVATIONS, THE RESULTING GRADE WILL
CORRESPOND WITH SAID SUB -BASE COURSE, ELEVATIONS ARE TO BE
CALCULATED FROM BENCHMARK, FINISHED GRADES, OR INDICATED SLOPES.
B CLEAR EXCESS SPOILS, IF ANY, FROM JOB SITE AND DO NOT SPREAD
BEYOND THE LIMITS OF PROJECT AREA UNLESS AUTHORIZED BY PROJECT
MANAGER AND AGREED TO BY LANDOWNER.
C. BRING THE ACCESS DRIVE W/ TURNAROUND TO BASE COURSE ELEVATION TO
FACILITATE CONSTRUCTION AND OBSERVATION DURING CONSTRUCTION
OF THE SITE.
D. AVOID CRATING DEPRESSIONS WHERE WATER MAY POND.
E. THE CONTRACT SHALL INCLUDE GRADING, BANKING, AND DITCHING, UNLESS
OTHERWISE INDICATED,
F, WHEN IMPROVING AN EXISTING ACCESS DRIVE, GRADE THE EXISTING DRIVE
TO REMOVE ANY ORGANIC MATTER AND SMOOTH THE SURFACE BEFORE
PLACING FILL OR STONE
G PLACE FILL OR STONE IN SIX INCH (6") MAXIMUM UFTS, AND COMPACT
BEFORE PLACING NEXT LIFT,
H.
BEYOND HE ONE FOOT (1')
SITE FENCE (UNLESS 0 HERWISE NOTED) AND SHALL
COVER THE AREA AS INDICATED,
I, APPLY RIPRAP TO THE SIDE SLOPES OF ALL FENCED SITE AREAS, PARKING
AREAS, AND ALL OTHER SLOPES GREATER THAN 2:1.
J APPLY RIPRAP TO THE SIDES OF DITCHES OR DRAINAGE SWALES.
C RIPRAP ENTIRE DITCH FOR SIX FEET (6') IN ALL DIRECTIONS AT CULVERT
OPENINGS,
L. APPLY SEED, FERTILIZER, AND STRAW COVER TO ALL OTHER DISTURBED
AREAS, DITCHES, AND DRAINAGE SWALES, NOT OTHERWISE RIPRAPPED.
M UNDER NO CIRCUMSTANCES WILL DITCHES, SWALES, OR CULVERTS BE PLACED
SO THAT THEY DIRECT WATER TOWARDS, OR PERMIT STANDING WATER
IMMEDIATELY ADJACENT TO SHELTER OR EQUIPMENT. IF DESIGNS OR ELEVATIONS
ARE IN CONFLICT WITH THIS, ADVISE CONSTRUCTION MANAGER IMMEDIATELY.
N. IN DITCHES WITH SLOPES GREATER THAN 10%, MOUND DIVERSIONARY
HEADWALLS IN THE DITCH AT CULVERT ENTRANCES, POSITION THE HEADWALL
AT AN ANGLE NO GREATER THAT 60- OFF THE DITCH LINE RIPRAP THE
UPSTREAM SIDE OF THE HEADWALL AS WELL AS THE DITCH FOR SIX FEET (6')
ABOVE THE CULVERT ENTRANCE,
0. APPLY SEED AND FERTILIZER TO SURFACE QONDITIONS WHICH WILL
ENCOURAGE ROOTING RAKE AREAS TO BE SEEDED TO EVEN THE
SURFACE AND LOOSEN THE SOIL
P. SOW SEED IN TWO DIRECTIONS IN TWICE THE QUANTITY RECOMMENDED
BY THE SEED PRODUCER
Q, ENSURE GROWTH OF SEEDED AND LANDSCAPED AREAS, BY WATERING,
UP TO THE POINT OF RELEASE FROM THE CONTRACT. CONTINUE TO
REWORK THE BARE AREAS UNTIL COMPLETE COVERAGE IS OBTAINED,
4. FIELD QUALITY CONTROL
COMPACT SOILS TO MAXIMUM DENSITY IN ACCORDANCE WITH ASTM D-1557.
AREAS OF SETTLEMENT WILL BE EXCAVATED AND REFILLED AT
CONTRACTOR'S EXPENSE. INDICATE PERCENTAGE OF COMPACTION
ACHIEVED ON AS -BUILT DRAWINGS
5. PROTECTION
A PROTECT SEEDED AREAS FROM EROSION BY SPREADING STRAW TO
A UNIFORM LOOSE DEPTH OF 1-2 INCHES, STAKE AND TIE DOWN AS
REQUIRED. USE OF EROSION CONTROL MESH OR MULCH NET WILL BE
AN ACCEPTABLE ALTERNATE
B ALL TREES PLACED IN CONJUNCTION WITH A LANDSCAPE CONTRACT
WILL BE WRAPPED, TIED WITH HOSE PROTECTED WIRE, AND SECURED
TO 2" X 2" X 4'-0" WOODEN STAKES EXTENDING TWO -FEET INTO THE
GROUND ON FOUR SIDES OF THE TREE
C PROTECT ALL EXPOSED AREAS AGAINST WASHOUTS AND SOIL
EROSION. PLACE STRAW BALES AT THE INLET APPROACH TO ALL
NEW OR EXISTING CULVERTS. WHERE THE SITE OR ROAD AREAS
HAVE BEEN ELEVATED IMMEDIATELY ADJACENT TO THE RAIL LINE,
STAKE EROSION CONTROL FABRIC FULL LENGTH IN THE SWALE TO
PREVENT CONTAMINATION OF THE RAIL BALLAST. ALL EROSION
CONTROL METHODS SHALL CONFORM TO APPLICABLE BUILDING
CODE REQUIREMENTS,
SEMN 029M - FENCING -Argo GATES)
PART I - GENERAL
1. WORK INCLUDED
SEE PLAN FOR SITE AND LOCATION OF FENCE AND GATE(S).
2, QUALIFY ASSURANCE
ALL STEEL MATERIALS UTILIZED IN CONJUNCTION WITH THIS SPECIFICATION WILL BE
GALVANIZED OR STAINLESS STEEL WEIGHT OF ZINC COATING ON THE FABRIC SHALL NOT BE
LESS THAN 12 OUNCES PER SQUARE FOOT OF MATERIAL COVERED. POSTS SHALL BE
HOT -DIPPED IN GRADE 'E' ZINC, 18 OUNCES PER SQUARE FOOT.
3. SEQUENCING
IF THE SITE AREA HAS BEEN BROUGHT UP TO SURFACE COURSE ELEVATION (PRIOR TO
THE FENCE CONSTRUCTION), FENCE POST EXCAVATION SPOILS MUST BE CONTROLLED TO
PRECLUDE CONTAMINATION OF SAID SURFACE COURSE
4 SUBMITTALS
A MANUFACTURER'S DESCRIPTIVE LITERATURE
B CERTIFICATE OR STATEMENT OF COMPLIANCE WITH THE SPECIFICATIONS
PART 2.- PIiODii
1. FENCE MATERIAL
A ALL FABRIC WIRE, RAILS, HARDWARE, AND OTHER STEEL MATERIALS SHALL BE
HOT -DIPPED GALVANIZED.
B, FABRIC SHALL BE SEVEN -FOOT (7') HIGH OR TO MATCH EXISTING FENCE
TWO-INCH CHAIN LINK MESH OF NO. 9 GAUGE ( 0.148`) WIRE.
THE FABRIC SHALL HAVE A KNUCKLED FINISH FOR THE TOP SELVAGES.
FABRIC SHALL CONFORM TO THE SPECIFICATIONS OF ASTM A-392 CLASS 1
C. BARBED WIRE SHALL BE DOUBLE -STRAND, 12-1/2 GAUGE TWISTED WIRE, WITH
14-GAUGE, 4-POINT ROUND BARBS SPACED ON FIVE -INCH CENTERS
D ALL POSTS SHALL BE SCHEDULE - 40 MECHANICAL SERVICE PIPE AND SHALL BE
TYPE 1 ASTM A-128 AND OF THE FOLLOWING DIAMETER
LIR2 1.1 411 2 B '
CORN R Ylar 4Q} II '
OQD
slri r MULE 40 s +I7 a.Q). E GATE POSTS SHALL BE EXTENDED 12 INCHES, INCLUDING DOME CAP, TO PROVIDE
FOR ATTACHMENT OF BARBED WIRE.
F. ALL TOP AND BRACE RAILS SHALL BE lI DIAMETER SCHEDULE - 40
MECHANICAL -SERVICE PIPE.
& GATE FRAMES AND BRACES SHALL BE 1 90 INCH DIAMETER SCHEDULE 40
MECHANICAL -SERVICE PIPE FRAMES SHALL HAVE WELDED CORNERS
FL GATE FRAMES SHALL HAVE A FULL -HEIGHT VERTICAL BRACE, AND A FULL -WIDTH
HORIZONTAL BRACE, SECURED IN PLACE BY USE OF GATE BRACE CAMPS
L GATE HINGES SHALL BE MERCHANTS METAL MODEL 64386 HINGE ADAPTER
WITH MODEL 6409. 188-DEGREE ATTACHMENT
J. THE GUIDE (LATCH ASSEMBLY) SHALL BE HEAVY INDUSTRIAL DOUBLE GATE LATCH.
SEE DETAIL
K. LATCHES AND STOPS SHALL BE PROVIDED FOR ALL GATES.
L PLUNGER ROD COMPLETE WITH RECEPTOR TO BE PROVIDED AT THE INACTIVE
LEAF OF ALL DOUBLE GATE INSTALLATIONS
M. ALL STOPS SHALL HAVE KEEPERS CAPABLE OF HOLDING THE GATE LEAF IN THE
OPEN POSITION
N, A ND. 7 GAUGE ZINC COATED TENSION WIRE SHALL BE USED AT THE BOTTOM OF
THE FABRIC, TERMINATED WITH BAND CUPS AT CORNER AND GATE POSTS
0. A SIX-INCH BY 1/2-INCH DIAMETER EYEBOLT TO HOLD TENSION WIRE SHALL BE
PLACED AT LINE POSTS,
P. STRETCHER BARS SHALL BE 3/16-INCH BY 3/4-INCH OR HAVE EQUIVALENT
CROSS -SECTIONAL AREA
Q, ALL CORNER GATE AND PANELS SHALL HAVE A 3/EL-INCH TRUSS ROD WITH
TURNBUCKLES
R. ALL POSTS EXCEPT GATE POSTS SHALL HAVE A COMBINATION CAP AND BARBED
WIRE SUPPORTING ARM, GATE POSTS SHALL HAVE A DOME CAP.
S OTHER HARDWARE INCLUDES BUT MAY NOT BE LIMITED TO TIE CLIPS, BAND CLIPS
AND TENSION BAND CLIPS,
T. BARBED WIRE GATE GUARDS SHALL BE FIRED WITH DOME CAPS -
Ill BARBED WIRE SUPPORT ARMS SHALL BE PRESSED STEEL COMPLETE WITH SET
BOLT AND LOCK WIRE IN THE ARM.
V ALL CAPS SHALL BE MALLEABLE IRON, DOME OR ACORN SHAPED AS
REQUIRED BY PIPE SIZE
W, WHERE THE USE OF CONCERTINA HAS BEEN SPECIFIED, 24-INCH DIAMETERS COIL
BARBED TAPE, STAINLESS STEEL, CYCLONE FENCE MODEL G8P TO TYPE IN SHALL
BE FURNISHED, IT SHALL BE SUPPORTED ABOVE THE TOP RAIL BY USE OF SIX(6)
WIRE BARBED WIRE ARMS POSITIONED ATOP EACH LINE/CORNER POST,
PART_AG#
1. INSPECTION
TO CONFIRM PROPER DEPTH AND DIAMETER OF POST HOLE EXCAVATIONS ALL POST
HOLES WILL BE EXCAVATED AS PER CONSTRUCTION DOCUMENTS
2, INSTALLATION
A, FOUNDATIONS SHALL HAVE A MINIMUM SIX INCH (6") CONCRETE COVER UNDER POST
B ALL FENCE POSTS SHALL BE VERTICALLY PLUMB ; ONE QUARTER INCH (1/47
C. AT CORNER POSTS, GATE POSTS, AND SIDES OF GATE FRAME, FABRIC SHALL BE
ATTACHED WITH STRETCHER AND TENSION BAND -CUPS AT FIFTEEN(15) INCH
INTERVALS.
D. AT LINE POSTS, FABRIC SHALL BE ATTACHED WITH BAND -CLIPS AT FIFTEEN
INCH (15`) INTERVALS,
E. FABRIC SHALL BE ATTACHED TO BRACE RAILS, TENSION WIRE AND TRUSS RODS
WITH TIE -CLIPS AT TWO FOOT (2') INTERVALS
F. A MAXIMUM GAP OF ONE INCH WILL BE PERMITTED BETWEEN TIE CHAIN LINE FABRIC
AND THE FINAL GRADE
G. GATE SHALL BE INSTALLED SO LOCKS ARE ACCESSIBLE FROM BOTH SIDES
H. GATE HINGE BOLTS SHALL HAVE THEIR THREADS PEENED OR WELDED TO PREVENT
UNAUTHORIZED REMOVAL
1, CONCRETE TO BE A MINIMUM OF 4,0D0 PSI AT 7 DAYS CEMENT SHALL EXCEED
ASTM C150, TYPE IIIA
3. PROTECTION
UPON COMPLETION
OF ERECTION, INSPECT FENCE MATERIAL AND PAINT FIELD CUTS OR
GALVANIZING BREAKS WITH ZINC -BASED PAINT, COLOR TO MATCH THE GALVANIZED METAL
APPLICABLE STANDARDS
ASTM-A120
SPECIFICATION FOR PIPE STEEL BLACK AND HOT -DIPPED ZINC
COATED (GALVANIZED) WELDED AND SEAMLESS, FOR
ORDINARY USES
ASrM-Al23
ZINC (HOT -DIP GALVANIZED) COATING ON IRON AND STEEL PRODUCTS.
ASTM-A153
STANDARD SPECIFICATION FOR ZINC COATING (HOT -DIP)
ON IRON AND STEEL HARDWARE.
ASTM-A392
SPECIFICATION FOR ZINC -COATED STEEL CHAIN LINK FENCE FABRIC
ASTM-A491
SPECIFICATION FOR ALUMINUM -COATED STEEL CHAIN LINK
FENCE FABRIC
ASTM-A525
STANDARD SPECIFICATION FOR STEEL SHEET ZINC COATED
(GALVANIZED) BY THE HOT -DIPPED PROCESS
ASTM-A570 SPECIFICATION FOR HOT -ROLLED CARBON STEEL SHEET AND STRIP
STRUCTURAL DUALITY
AS1M-A535 SPECIFICATION FOR ALUMINUM COATED STEEL BARBED WIRE
FEDERAL SPECIFICATION RR-F-191- FENCING, WIRE AND FOST METAL (AND GAIES,
CHAIN LINK FENCE FABRIC, AND ACCESSORIES)
DIVISION 3: CONCRETE
SECTIF n9= - BASIC CONCREM M6ARMLS AND 80
PART 1 -GENERAL
1 WORK INCLUDED
FORMWORK, REINFORCEMENT, ACCESSORIES, CAST -IN -PLACE CONCRETE,
FINISHING. AND CURING
2 INSPECTIONS
A CONTRACTOR IS RESPONSIBLE FOR SCHEDULING BUILDING DEPARTMENT
INSPECTIONS N REQUIRED FOR HIS SCOPE OF WORK
B ALL REINFORCING STEEL SHALL BE INSPECTED AND APPROVED BY THE
LESSEE'S CONSTRUCTION MANAGER PRIOR TO PLACEMENT OF CONCRETE
C THE LESSEE'S CONSTRUCTION MANAGER SHALL BE NOTIFIED NO LESS THAN 46
HOURS IN ADVANCE OF CONCRETE POURS.
QUALITY ASSURANCE
3 A CONSTRUCT AND ERECT CONCRETE FORMWORK IN ACCORDANCE WITH
ACI 301 AND ACI 318.
B. PERFORM CONCRETE REINFORCING WORK IN ACCORDANCE WITH ACI 301.
ACI 318. AND ASTM A184
C. PERFORM CAST -IN -PACE CONCRETE WORK IN ACCORDANCE WITH ACI 301.
ACI 318, AND ACI 117-90.
D. OPEN FOUNDATION TRENCHES SHALL BE INSPECTED BY MIES PRIOR
TO CONCRETE INSTALLATION,
4 SUBMITTALS
WEmIT 1=1REFL MIX AND RIEN%IN IppWING STEEL SHOP DRAWINGS EDR
APPROVAL BY LE55EE CON?ZPifCTIOk T,µRAOER/ENOINEER. THE SHOP
INFORMATIONH 511EF.T5 "M O (Z) BLUELINE WAWINtS(FOR9BRI'TRC NIG STEEL.
PART E - PROUOLiR
1 REINFORCEMENT MATERIALS
A REINFORCEMENT STEEL, ASTM A615, 60 ksi YIELD GRADE, DEFORMED BILLET
STEEL BARS, PWN FINISH
R WELDED STEEL WIRE FABRIC ASTM A185 PLAIN TYPE, IN FLAT SHEETS. PLAIN
FINISH
G CHAIRS BOLSTERS, BAR SUPPORTS, SPACERS SIZED AND SHAPED FOR
SUPPO(ZR OF REINFORCING.
D. FABRICATE CONCRETE REINFORCING IN ACCORDANCE WITH ACI 315. ACI 310,
ASTM A184
2 CONCRETE MATERIALS
A CEMENT: ASTM C150, PORTIAND TYPE
B FINE AND COURSE AGGREGATES: ASTM C33 - MAXIMUM SIZE OF CONCRETE
A6CASL'ATE SHALL NOT EXCEED ; ONE INCH (1 SIZE SUITABLE FOR
INSTALLATION METHOD UTILIZED OR ONE-THIRD 1/3) CLEAR DISTANCE BEHIND
OR BETWEEN REINFORCING
C WATER: CLAN AND NOT DETRIMENTAL TO CONCRETE
D AIR ENTRAINING ADMIXTURE: ASTM C260
E BONDING AGENT: LATEX EMULSION FOR BONDING NEW TO OLD CONCRETE AS
MANUFACTURED BY DAYTON SUPERIOR.
F NON -SHRINK GROUT: PREMIXED COMPOUND CONSISTING OF NONMETALLIC
AGGREGATE CEMENT, WATER REDUCING AND PLASTICISING AGENTS
3, CONCRETE MIX
A CONCRETE MATERIALS SHALL CONFORM TO THE APPROPRIATE ACT
REQUIREMENTS FOR EXPOSED STRUCTURAL CONCRETE
B MIX AND DELIVER CONCRETE IN ACCORDANCE WITH ASTM C94, ALT. 3
C PROPORTIONS OF CONCRETE MATERIALS SHALL BE SUITABLE FOR THE
INSTALLATION METHOD UTILIZED AND SHALL RESULT IN DURABLE CONCRETE
FOR LOCAL ANTICIPATED AGGRESSIVE ACTIONS THE DURABIUTY
REQUIREMENTS OF ACI 31B CHAPTER 4 SHALL BE SATISFIED BASED ON THE
CONDITIONS EXPECTED AT THE SITE PROVIDE CONCRETE AS FOLLOWS:
1. COMPRESSIVE STRENGTH: 4000 psi AT 7 DAYS
SEE SHEET S-1 FOR CAISSON CONCRETE COMPRESSIVE STRENGTH
2. SLUMP: 3 INCHES
P1RT 3 - >l1H' CU7Rffl
1 INSERTS, EMBEDDED COMPONENTS AND OPENINGS
A THE CONTRACTOR SHALL COORDINATE AND CROSS-CHECK ARCHITECTURAL,
BUILDING & ELECTRICAL DRAWINGS FOR OPENINGS, SLEEVES, ANCHORS, HANGERS,
AND OTHER ITEMS RELATED TO CONCRETE WORK AND SHALL ASSUME FULL
RESPONSIBILITY FOR THE PROPER LOCATION BEFORE PACING CONCRETE
B. PROVIDE FORMED OPENINGS WHERE REQUIRED FOR WORK TO BE EMBEDDED
IN AND PASSING THROUGH CONCRETE MEMBERS
G COORDINATE WORK OF OTHER SECTIONS IN FORMING AND SETTING OPENING,
SLOTS, RECESSES, CHASES, SLEEVES, BOLTS, ANCHORS, AND OTHER INSERTS.
D. INSTALL CONCRETE ACCESSORIES STRAIGHT, LEVEL AND PLUMB
2. REINFORCEMENT PLACEMENT
A. PLACE REINFORCEMENT, SUPPORTED AND SECURED AGAINST DISPLACEMENT,
B. ENSURE REINFORCING IS CLEAN, FREE OF LOOSE SCALE, DIRT, OR OTHER
FOREIGN COATINGS
G WELDING IS PROHIBITED ON REINFORCING STEEL AND EMBEDMENT&
D MINIMUM CONCRETE COVER FOR REINFORCING SHALL BE THREE INCHES (3") UNLESS
OTHERWISE NOTED.
E. CONCRETE COVER FROM TOP OF FOUNDATION TO ENDS OF VERTICAL
REINFORCEMENT SHALL NOT EXCEED THREE INCHES (37 NOR BE LESS THAN TWO INCHES (2").
3. PLACING CONCRETE
A VIBRATE ALL CONCRETE
B. ALL CONCRETE WORK SHALL ADHERE TO THE LATEST ACA STANDARDS FOR
WINTER POURING AND CURING PROCEDURES IF SEASONAL CONDITIONS APPLY
4, CURING
A AFTER PLACEMENT, PROTECT CONCRETE FROM PREMATURE DRYING
B. MAINTAIN CONCRETE WITH MINIMAL MOISTURE LOSS AT RELATIVELY CONSTANT
TEMPERATURE FOR A PERIOD NECESSARY FOR HYDRATION OF CEMENT AND
HARDENING OF CONCRETE,
5. PROVIDE HAND RUBBED SMOOTH FINISH TO ALL EXPOSED VERTICAL FORMED
CONCRETE SURFACES
6. FIELD QUALITY CONTROL
A SUBMIT THREE (3) CONCRETE TEST CYLINDERS - TAKEN FOR EVERY 15 CUBIC
YARD OR LESS, SUBMIT CONCRETE TESTS TO THE PROJECT MANAGER IN
ACCORDANCE WITH ASTM , C-31 AND C-39.
B SUBMIT ONE (1) ADDITIONAL TEST CYLINDER - TAKEN DURING COLD WEATHER
POURS, AND CURED ON JOB SITE UNDER SAME CONDITIONS AS CONCRETE
IT REPRESENTS,
C. SUBMIT ONE (1) SLUMP TEST - TAKEN FOR EACH SET OF TEST CYLINDERS
TAKEN
7, DEFECTIVE CONCRETE
MODIFY OR REPLACE CONCRETE NOT CONFORMING TO REQUIRED LINES, DETAILS
OR ELEVATIONS AT COST OF GC, AS DIRECTED BY ARCHITECT/ENGINEER.
0
o r�
omrn,�
< w dm
0E��lo
J O
No
OEDE�CO I,, < '
�w2bw
o O Z LL
~Ja
Of
L]
I
Wm3
max
IW-
¢
C
m
ry
Z
0
/n
z
w
a
U
>
_
DO
Of
a
o
K
o
U
w
o
O
z
50000898289
MDG #
W12
NKORK RSW
404W STATE HWY 70
PARK FALLS, WI 54552
DRAWN BY AC
CHECKED BY PP
DATE 07/12/24
PROJECT #: 194-168
SHEET TITLE
GENERAL
NOTES
SHEET NUMBER
SP_I
L11VI5ION 5_ N}IAL-
PART 1 - GENERAL
1, SECTION INCLUDES:
STRUCTURAL STEEL FRAMING MEMBERS, BASE PLATES, PLATES, BARS AND
GROUTING UNDER BASE PLATES
2. SUBMITTALS:
SHOP DRAWINGS: INDICATE SIZES, SPACING, AND LOCATIONS OF STRUCTURAL
MEMBERS, OPENINGS, CONNECTIONS, CAMBERS, LOADS, AND WELDED SECTIONS.
3 QUALITY ASSURANCE
A FABRICATE STRUCTURAL STEEL MEMBERS IN ACCORDANCE WITH AISC
SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF
STRUCTURAL STEEL FOR BUILDINGS
B PERFORM DESIGN UNDER DIRECT SUPERVISION OF A PROFESSIONAL
STRUCTURAL ENGINEER LICENSED IN THE STATE.
PARE 7
PRODUCTS
I MATERIALS:
A
STRUCTURAL STEEL MEMBERS:
B
STRUCTURAL TUBING:
C.
PIPE:
D-
BOLTS, NUTS, AND WASHERS:
E.
ANCHOR BOLTS:
F
WELDING MATERIALS:
G.
GROUT:
ASTM A572, GRADE 50
ASTM A500, GRADE B
ASTM A53, TYPE E OR S, GRADE B
ASTM A325
ASTM A307
AWS D1.1, TYPE REQUIRED FOR
MATERIALS BEING WELDED
NON -SHRINK TYPE, PREMIXED COMPOUND
CONSISTING OF NONMETALLIC AGGREGATE,
CEMENT, WATER REDUCING AND PLASTICIZING
ADDITIVES, CAPABLE OF DEVELOPING
A MINIMUM COMPRESSIVE STRENGTH
OF 7000 psi AT 28 DAYS
H, SHOP AND TOUCH-UP PRIMER: SSPC 15, TYPE I, RED OXIDE
I. TOUCH-UP PRIMER
FOR GALV, SURFACES: ZINC RICH TYPE
2. FABRICATION:
CONTINUOUSLY SEAL JOINTED MEMBERS BY CONTINUOUS WELDS GRIND EXPOSED
WELDS SMOOTH,
3. FINISH:
A PREPARE STRUCTURAL COMPONENT SURFACES IN ACCORDANCE WITH SSPC
SP-1 TO SP-10 PROCEDURES,
B. STRUCTURAL STEEL MEMBERS SHALL BE HOT DIPPED GALVANIZED.
,p�1 .1 - EILBCUTION
1. E%AMINATION AND PREPARATION:
VERIFY THAT THE FIELD CONDITIONS ARE ACCEPTABLE,
2. ERECTION:
A ALLOW FOR ERECTION LOADS. PROVIDE TEMPORARY BRACING TO MAINTAIN
FRAMING IN ALIGNMENT UNTIL COMPLETION OF ERECTION AND INSTALLATION
OF PERMANENT BRIDGING AND BRACING,
B. FIELD WELD COMPONENTS INDICATED ON SHOP DRAWINGS.
C. DO NOT FIELD CUT OR ALTER STRUCTURAL MEMBERS WITHOUT APPROVAL
OF THE ARCHITECT/ENGINEER.
1), AFTER ERECTION, TOUCH-UP WELDS, ABRASIONS, AND SURFACES NOT SHOP
PRIMED OR GALVANIZED WITH TOUCH-UP PRIMERS AS SPECIFIED UNDER SECTION
D500D,-METALS, PART 2 - PRODUCTS, H & I, SURFACES TO BE IN CONTACT
WITH CONCRETE NOT INCLUDED.
3. FIELD QUALITY CONTROL:
FIELD INSPECTION OF MEMBERS, CONNECTIONS, WELDS AND TORQUING,
❑IVISION CTRICAL
5FCT)DN 16ID50 - BASIC 6LSORICALMAMRIALS AND IdET OD5
1 CONTRACTOR SHALL REVIEW THE CONTRACT DOCUMENTS PRIOR
TO ORDERING THE ELECTRICAL EQUIPMENT AND STARTING
THE ACTUAL CONSTRUCTION. CONTRACTOR SHALL ISSUE A WRITTEN
NOTICE OF ALL FINDINGS TO THE ARCHITECT LISTING ANY DISCREPANCIES
OR CONFLICTING NFORMATION,
2, ELECTRICAL PLANS, DETAILS AND DIAGRAMS ARE DIAGRAMMATIC ONLY,
VERIFY EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL
EQUIPMENT WITH OWNER PRIOR TO INSTALLATION.
3. EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED
IN EACH PANELBOARD, PULLBOX, JUNCTION BOX, SWITCH BOX, ETC.
THE TYPE OF TAGGING METHODS SHALL BE IN COMPLIANCE WITH
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (O,S.H.A).
4. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN GOOD WORKING
CONDITION WHEN INSTALLED AND SHALL BE OF THE BEST GRADE AND OF THE
SAME MANUFACTURER THROUGHOUT FOR EACH CLASS OR GROUP OF EQUIPMENT
MATERIALS SHALL BE LISTED "J" WHERE APPLICABLE MATERIALS SHALL MEET
WITH APPROVAL OF ALL GOVERNING BODIES HAVING JURISDICTION. MATERIALS
SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS
ESTABLISHED BY ANSI, NEMA, NBFU AND "UL" LISTED.
5 ALL CONDUIT SHALL HAVE A PULL CORD.
6 PROVIDE PROJECT MANAGER WITH ONE SET OF COMPLETE ELECTRICAL
"AS INSTALLED" DRAWINGS AT THE COMPLETION OF THE JOB, SHOWING
ACTUAL DIMENSIONS, ROUTINGS, AND CIRCUITS.
7. ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE
AN INTERRUPTING SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE
SUBJECTED, AND A MINIMUM OF 10,000 AI -C-
B THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS REQUIRED
BY UBC, NEC AND ALL APPLICABLE CODES.
9. PATCH, REPAIR AND PAINT ANY AREA THAT HAS BEEN DAMAGED IN THE
COURSE OF THE ELECTRICAL WORK
10. PLASTIC PLATES FOR ALL SWITCHES, RECEPTACLES, TELEPHONE
AND BLANKED OUTLETS SHALL HAVE ENGRAVED LETTERING WHERE
INDICATED ON THE DRAWINGS WEATHERPROOF RECEPTACLES
SHALL HAVE SIERRA NWPD-B LIFT COVERPLATES,
UG`HON 154iM - SERVICE ANJ2_,T15TRIBUTIald
1 WIRE AND CABLE CONDUCTORS SHALL BE COPPER, 600V, TYPE THHN OR THWN,
WITH A MIN. SIZE OF #12 AWG, COLOR CODED ALL RECTIFIER DROPS SHALL BE
STRANDED TO ACCEPT CRIMP CONNECTORS
2, ALL CHEMICAL GROUND RODS SHALL BE "UL" APPROVED-
3 METER SOCKET AMPERES, VOLTAGE, NUMBER OF PHASES SHALL BE AS NOTED
ON THE DRAWINGS MANUFACTURED BY MILBANK OR APPROVED EQUAL,
AND SHALL BE UTILITY COMPANY APPROVED.
4. CONDUIT:
A RIGID CONDUIT SHALL BE U,L LABEL GALVANIZED ZINC COATED WITH
GALVANIZED ZINC INTERIOR AND SHALL BE USED WHEN INSTALLED IN OR
UNDER CONCRETE SLABS, IN CONTACT WITH THE EARTH, UNDER PUBLIC
ROADWAYS, IN MASONRY WALLS OR EXPOSED ON BUILDING EXTERIOR.
RIGID CONDUIT IN CONTACT WITH EARTH SHALL BE 1/2 LAPPED WRAPPED
WITH HUNTS WRAP PROCESS NO. 3
B. ELECTRICAL METALLIC TUBING SHALL HAVE U.L LABEL, FITTING SHALL
BE GLAND RING COMPRESSION TYPE
C. FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L LISTED LABEL AND
MAY BE USED WHERE PERMITTED BY CODE FITTINGS SHALL BE
"JAKE" OR "SQUEEZE" TYPE ALL FLEXIBLE CONDUITS SHALL HAVE
FULL LENGTH GROUND WIRE
D ALL UNDERGROUND CONDUIT SHALL BE AS NOTED ON THE DRAWINGS
AT A MINIMUM DEPTH OF 42" BELOW GRADE, IT IS REQUIRED AND WILL
BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO NOTIFY
DIGGERS HOTLINE AT 1-500-242-8511 OR OTHER SUCH NOTIFYING AGENCY
THIRTY-SIX (36) HOURS PRIOR TO DIGGING,
5 CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR CONNECTION
OF TEMPORARY AND PERMANENT POWER TO THE SITE THE TEMPORARY
POWER AND ALL HOOKUP COSTS ARE TO BE PAID BY THE CONTRACTOR.
61 ALL ELECTRICAL EQUIPMENT SHALL BE LABELED WITH PERMANENT
ENGRAVED PLASTIC LABELS WITH WHITE ON BLUE BACKGROUND LETTERING
(MINIMUM LETTER HEIGHT SHALL BE ONE FORTH INCH (1/4") NAMEPLATES SHALL BE FASTENED
WITH STAINLESS STEEL SCREWS, NOT ADHESIVE.
7. UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALL
POTENTIAL GROUNDING TESTS BY AN INDEPENDENT TESTING SERVICE ENGAGED BY
THE CONTRACTOR SHALL BE SUBMITTED FOR APPROVAL SUBMIT TEST REPORTS
TO PROJECT MANAGER. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK
AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDITION.
B. GROUNDING ELECTRODE SYSTEM
A PREPARATION
1, SURFACE PREPARATION:
ALL CONNECTIONS SHALL BE MADE TO BARE METAL ALL PAINTED
SURFACES SHALL BE FIELD INSPECTED AND MODIFIED TO ENSURE
PROPER CONTACT. NO WASHERS ARE ALLOWED BETWEEN THE ITEMS
BEING GROUNDED. ALL CONNECTIONS ARE TO HAVE A NON -OXIDIZING
AGENT APPLIED PRIOR TO INSTALLATION
2. GROUND BAR PREPARATION:
ALL COPPER GROUND BARS SHALL BE CLEANED, POLISHED AND A
NON -OXIDIZING AGENT APPLIED, NO FINGERPRINTS OR DISCOLORED
COPPER WILL BE PERMITTED.
3. SLEEVES:
ALL GROUNDING CONDUCTORS SHALL RUN THROUGH PVC SLEEVES
WHEREVER CONDUCTORS RUN THROUGH WALLS, FLOORS OR CEILINGS
IF CONDUCTORS MUST RUN THROUGH EMT, BOTH ENDS OF CONDUIT SHALL
BE GROUNDED. SEAL BOTH ENDS OF CONDUIT WITH SILICONE CAULK,
B. GROUND BARS
1, ALL GROUND BARS SHALL BE ONE FORTH INCH (1/4") THICK TINNED COPPER PLATE
AND OF SIZE INDICATED ON DRAWINGS,
2- ALL CONNECTIONS TO THE GROUND BAR SHALL OBSERVE THE
FOLLOWING SEQUENCE:
A BOLT -HEAD
B. 2-HOLE LUG
C. TINNED COPPER BUSS BAR
U STAR WASHER
E. NUT
C. EXTERNAL CONNECTIONS
1 ALL BURIED GROUNDING CONNECTIONS SHALL BE MADE BY THE EXOTHERMIC
WELD PROCESS, CONNECTIONS SHALL INCLUDE ALL CABLE TO CABLE, SPLICES,
TEES, CROSSES, ETG ALL CABLE TO GROUND RODS, GROUND ROD SPLICES
AND LIGHTNING PROTECTION SYSTEMS ARE TO BE AS INDICATED. ALL
MATERIALS USED (MOLDS, WELDING METAL, TOOLS, ETC.) SHALL BE BY
'CADWELD' AND INSTALLED PER MANUFACTURER'S RECOMMENDED PROCEDURES
2. ALL ABOVE GRADE GROUNDING AND BONDING CONDUCTORS SHALL BE
CONNECTED BY TWO HOLE CRIMP TYPE (COMPRESSION) CONNECTIONS (EXCEPT 10
FOR THE ACEG AND GROUND ROD) MECHANICAL CONNECTIONS, FITTINGS OR
CONNECTIONS THAT DEPEND SOLELY ON SOLDER SHALL NOT BE USED. ALL
CABLE TO CABLE CONNECTIONS SHALL BE HIGH PRESSURE DOUBLE CRIMP
TYPE CONNECTIONS CONNECTIONS TO STRUCTURAL STEEL SHALL BE
EXOTHERMIC WELDS.
D, GROUND RODS
ALL GROUND RODS SHALL BE 5/6-INCH DIAMETER X 10'-0- LONG "COPPERWELD"
OR APPROVED EQUAL, OF THE NUMBER AND LOCATIONS INDICATED, GROUND
RODS SHALL BE DRIVEN FULL LENGTH VERTICAL IN UNDISTURBED EARTH,
E GROUND CONDUCTORS
ALL GROUND CONDUCTORS SHALL BE STANDARD TINNED SOLID BARE COPPER
ANNEALED, AND OF SIZE INDICATED ON DRAWINGS UNLESS NOTED OTHERWISE
1.
R LUGS
1, LUGS SHALL BE 2-HOLE, LONG BARREL, STRAND COPPER UNLESS OTHERWISE
SPECIFIED IN THE CONTRACT DOCUMENTS LUGS SHALL BE THOMAS AND
SETTS SERIES #548_ _BE OR EQUIVALENT
A. 535 MCM DLO 54880BE
B. 262 MCM DLO 54872EIE
C 01/0 DLO 548
62BE
D #4/0 THWN AND BARE 54866BE
E. N2/0 THWN 54862BE
F. 2 THHN 54207BE
G 6 DLO 54205BE
2, WHEN THE DIRECTION OF THE CONDUCTOR MUST CHANGE, IT
SHALL BE DONE GRADUALLY. THE CURVATURE OF THE TURN
SHALL BE DONE IN ACCORDANCE WITH THE FOLLOWING CHART:
MINIMUM BENDING
CRDUNOIHG CONDUCTOR_56E RMIUS TO W90L EOCE
N0. 6 AWG TO NO, 4 AWG 6 INCHES
N0. 2 AWG TO NO. 1/0 AWG B INCHES
N0. 2/0 AWG TO 4/0 MCM 12 INCHES
250 MCM TO 750 MCM 24 INCHES
SE&33i)N 1fi741; - TFLECOMM{)NI('F11I{IN{'"MPONFINTS
m
G
GROUND RING
(COAXIAL ANTENNA COBS
1 THE EXTERNAL GROUND RING ENCIRCLING THE TOWER (IF APPLICABLE) AND
BEIWEEN THE EQUIPMENT SHELTER PLATFORM ANCHORS SHALL BE MINIMUM
O O
NO 2 A.SOLID TINNED BARE COPPER CONDUCTOR IN DIRECT CONTACT
I.
GENERAL
a0 Uj m I
WITH THE EARTH AT THE DEPTH INDICATED ON THE DRAWINGS. CONDUCTOR
BENDS SHALL HAVE A MINIMUM BENDING RADIUS OF EIGHT INCHES (B')
A ALL MATERIALS, PRODUCTS OR PROCEDURES INCORPORATED INTO
. H- 3 to m
D
V) O ^o
WORK SHALL BE NEW AND OF STANDARD COMMERCIAL QUALITY
J O r
m
2 ALL EXTERNAL GROUND RINGS ARE TO BE JOINED TOGETHER AND ALL
CONNECTIONS MUST BE CADWELDED. NO LUGS OR CLAMPS WILL BE
ACCEPTED
B CERTAIN MATERIALS AND PRODUCTS WILL BE SUPPLIED BY THE OWNER (REFER
TO GENERAL CONDITIONS FOR THE LIST OF OWNER FURNISHED EQUIPMENT,
If O N Q
CD Of W W oD
MATERIALS AND SUPPLIES FOR THESE ITEMS) THE CONTRACTOR IS RESPONSIBLE
O O, Z X
H.
FENCE GATE
/
GROUND EACH GATE POST, CORNER POST AND GATE AS INDICATED
F A L UCH MATERIALS FOR PICKUP AND DELIVERY 0 L S
O Z o LL
J a
ON DRAWING GROUND CONNECTIONS TO FENCE POSTS AND ALL OTHER
C ALL OTHER MATERIALS AND PRODUCTS SPECIFIED IN THE CONTRACT
CONNECTIONS FOR THE GROUND GRID SYSTEM SHALL BE MADE BY
DOCUMENTS SHALL BE SUPPLIED BY THE CONTRACTOR
O
EXOTHERMIC WELD PROCESS, AND INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS AND PROCEDURES, AND SPRAYED WITH COLD -
GALVANIZED PAINT 2 MATERIALS:
IEEE, FALL
POTENTIAL TESTS
A COAXIAL CABLE:
A
FOR RAW LAND SITE
1 INSTALL COAXIAL CABLE AND TERMINATIONS BETWEEN ANTENNAS
.$
I- GROUND TESTS SHALL BE PERFORMED AS INDICATED ON DRAWINGS.
AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS
WITH COAXIAL CABLES SUPPORTED AT NO MORE THAN 3'-0" O,C
< ¢
5x 8S
A BIDDLE GROUND OHMER OR THE METHOD OF USING TWO AUXILIARY
GROUND RODS (AS DESCRIBED IN IEEE STANDARDS NO 81-1983.
PART 1) MAY BE USED THE LEEE METHOD REQUIRES THE USE OF AN
WEATHERPROOF ALL CONNECTORS BETWEEN THE ANTENNA AND
EQUIPMENT PER MANUFACTURERS' REQUIREMENTS TERMINATE
J 44
x
MUST BE SUFFICIENTLY
ALL COAXIAL CABLE THREE FEET (3•) IN EXCESS OF EQUIPMENT
W
AG TEST CURRENT, THE AUXILIARY TEST RODS
FAR AWAY FROM THE ROD UNDER TEST SO THAT THE REGIONS IN WHICH
LOCATION UNLESS OTHERWISE STATED
THEIR RESISTANCE IS LOCALIZED DO NOT OVERLAP THE TEST POINT
2, ALL COAX RUN LENGTHS GREATER THAN 175 FEET SHALL BE
WILL BE THE GROUND ROD AND WILL CONSIST OF THE THREE POINT
ALL COAX, RUN LENGTH BETWEEN 101 FEET AND 174 FEET SHALL BE 1-1/4,
$ d
FALL OF POTENTIAL MEGGER TEST METHOD, USING THE BIDDLE NULL-
AND IN LENGTH LESS THAN OR EQUAL TO 100 FEET SHALL BE 7/8".
BALANCE EARTH TESTER (MEGGER #250220-2 OR EQUIVALENT)
2 CONTRACTOR TO CONDUCT GROUND RESISTANCE TEST IN THE FORMAT
AS FOLLOWS:
3
ANTENNA AND COAXIAL CABLE GROUNDING
,�
--
A ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON
B
EQUIPMENT PAD
STRAIGHT RUNS OF COAXIAL CABLE (NOT WITHIN BENDS)
4.
COAXIAL CABLE IDENTIFICATION
1, FIRST TEST - SHALL BE WITH FOUR GROUND RODS INSTALLED, ONE
AT EACH CORNER OF THE PAD BUT NOT CONNECTED TO THE
A TO PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF
Y
MAIN GROUNDING BUS FURNISH WIRE TO CONNECT (TEMPORARY
ANTENNA CABLING, PLASTIC TAGS SHALL BE USED AT THE
m
a
CLAMP) ALL FOUR GROUND RODS TOGETHER TO MAKE A SYSTEM
FOLLOWING LOCATIONS:
TEST AFTER EACH ROD IS INDIVIDUALLY TESTED. IF ANY INDIVIDUAL
ROD TESTS 25 OHMS OR MORE, THE ELECTRICAL CONTRACTOR AND
1 FIRST LOCATION IS AT THE END OF THE COAX NEAREST
OWNER'S REPRESENTATIVE SHOULD BE NOTIFIED SO THAT THE ROD
CAN BE DRIVEN DEEPER UNTIL ALL FOUR RODS HAVE A RESISTANCE
THE ANTENNA (WHERE THE COAXIAL CABLE AND JUMPER
ARE CONNECTED)
IL
G
m
Q
$
OF 10 OHMS OR LESS ON A DRY DAY.
2 SECOND LOCATION IS INSIDE THE EQUIPMENT SHELTER
NEAR THE WAVEGUIDE ENTRY PORT
2 SECOND TEST - SHALL BE WITH THE GROUND RODS CONNECTED,
WITH DRY SOIL AND WHEN NO STANDING WATER HAS BEEN PRESENT
B USE ANDREW CABLE TIES (PTO 27290) TO SECURE IDENTIFICATION TAGS
FOR THE PAST TEN (10) DAYS. THE MAXIMUM ALLOWABLE READING IS
5 OHMS TO GROUND. IF THE RESISTANCE OF THE ENTIRE SYSTEM EXCEEDS
5 OHMS, NOTIFY THE CONTRACTOR AND OWNER'S REPRESENTATIVE
5
TESTING
SO THAT ADDITIONAL AND/OR DEEPER RODS CAN BE INSTALLED.
LESSEE SHALL PROVIDE AN INDEPENDENT TESTING AGENCY TO
z
PERFORM THE COAXIAL SWEEP TEST &REPORT THE CONTRACTOR IS TO
Z
C.
TOWER
PROVIDE ONE CLIMBER /QUALIFIED TO ASSIST ANY REPAIRS
O
EST IS
AND WEATHERPROOFING ONCE THE TEST IS COMOM CONTRACTOR THE CONTRACTOR IS
w
a
1. FIRST TEST -SHALL BE WITH THREE GROUND RODS INSTALLED (MINIMUM).
TO PROVIDE LESSEE WITH A MINIMUM OF 40 HOURS NOTICE PRIOR TO THE
5
O
>
T.
EQUALLY SPACED AROUND THE TOWER FOUNDATION, BUT NOT
CONNECTED TO THE SHELTER PAD EXTERNAL GROUND RING
TIME OF THE SWEEP TEST.
U1
Of
a
FURNISH WIRE TO NNECT (TEMPORARY CLAMP) ALL THREE GROUND
U
LL
RODS TOGETHER TOCOMAKE A SYSTEM TEST AFTER EACH ROD IS
rn
j
INDIVIDUALLY TESTED IF ANY INDIVIDUAL ROD TESTS 25 OHMS
OR MORE, NOTIFY THE CONTRACTOR AND OWNER'S REPRESENTATIVE
_
SO THAT THE ROD CAN BE DRIVEN DEEPER UNTIL ALL THREE (3) RODS
HAVE A RESISTANCE OF 10 OHMS OR LESS ON A DRY DAY.
2. SECOND TEST - SHALL BE WITH THE GROUND RODS CONNECTED.
WITH DRY SOIL AND WHEN NO STANDING WATER HAS BEEN PRESENT
FOR THE PAST TEN (10) DAYS THE MAXIMUM ALLOWABLE READING IS
5 OHMS TO GROUND, IF THE RESISTANCE OF THE ENTIRE SYSTEM
EXCEEDS 5 OHMS THE ELECTRICAL CONTRACTOR AND OWNER'S
REPRESENTATIVE SHOULD BE NOTIFIED SO THAT EITHER
ADDITIONAL AND/OR DEEPER RODS CAN BE INSTALLED.
a
50000898289
D EQUIPMENT PAD AND TOWER
1- AFTER THE EQUIPMENT PAD AND TOWER GROUND RESISTANCE TEST
IS COMPLETED, CONTRACTOR SHALL TIE EQUIPMENT PAD EXTERNAL
GROUND RING AND TOWER EXTERNAL GROUND RING TOGETHER AFTER
MDG #
FIRST AND SECOND TEST ALL CONNECTIONS MUST BE MADE USING
EXOTHERMIC WELD. NO LUGS OR CLAMPS WILL BE ACCEPTED.
2. AFTER ALL THE EXTERNAL GROUND RINGS ARE TIED TOGETHER, COMPLETE
A MEGGER CHECK OF THE GROUND SYSTEM SHOULD BE DONE THE MAXIMUM
W12
ALLOWABLE LEADING IS 5 OHMS TO GROUND
NKORK RSW
GROUNDING RESISTANCE TEST REPORT
UPON COMPLETION OF THE TESTING FOR EACH SITE. A TEST REPORT
SHOWING RESISTANCE IN OHMS WITH AUXILIARY POTENTIAL ELECTRODES AT
5 FEET AND 10 FEET INTERVALS UNTIL THE AVERAGE RESISTANCE STARTS
INCREASING AND ALSO NOTE THAT 10-15 PHOTOS MUST BE TAKEN TO PROOF
ENTIRE EXTERNAL GROUND RING SYSTEM BEFORE BACKFILL TWO (2) SETS OF
TEST DOCUMENTS ARE OF THE INDEPENDENT TESTING SERVICE TO BE BOUND
AND SUBMITTED WITHIN ONE (1) WEEK OF WORK COMPLETION
gcnoN 105o3 — POLES
(SINGLE MAST AND SELr $LIPPORTING TOWEW
GENERAL
A, LIGHTNING ROD AND EXTENSION PIPE INCLUDING ALL APPURTENANCES.
TO BE FURNISHED BY OWNER, IF REQUIRED
B, PROVIDE TEMPORARY LIGHTING FOR TOWER AS PER FAA REGULATIONS
DURING CONSTRUCTION. IF REQUIRED,
C. GROUNDING:
GROUND TOWER WITH A MINIMUM OF 02 AWG TINNED SOLID BARE COPPER
CONDUCTOR CADWELDED TO TOWER BASE PLATE. TWO (2) GROUNDING
LEADS PER TOWER BASE PLATE
NO EXQTHERf11C WELDS SHALL BE AiT'ACWED DIRECTLY TD
jHE uCNDP ILE TOWER SHAFT.
404W STATE HWY 70
PARK FALLS, WI 54552
DRAWN BY AC
CHECKED BY PP
DATE 07/12/24
PROJECT H: 194-168
SHEET TITLE
GENERAL
NOTES
SHEET NUMBER
SP-2