Loading...
HomeMy WebLinkAbout024-741-29-4301-LUP-2024-243Du_1uth Superior Lake Nebagamon N Ashland R!4'!: I Mellen C1lcquamcgorl National Forest Hayward r-j "t Park r'r�lll>s I Shell Lake VICINITY MAP COMPLIANCE CODE ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 20151BC NATIONAL ELECTRICAL CODE (NFPA 70, NEC 2017 W/ AMND) 2015 WISCONSIN MECHANICAL CODE (IMC 2015 W/ AMND) 2018 WISCONSIN UNIFORM PLUMBING CODE (UPC) 2015 WISCONSIN ENERGY CONSERVATION CODE (IECC 2015 W/ AMND) 2015 WISCONSIN FIRE CODE (IFC 2015 W/ AMND) WISCONSIN COMMERCIAL BUILDING CODE WISCONSIN UNIFORM DWELLING CODE (UDC) 2015 WISCONSIN FUEL GAS CODE (IFGC 2015 W/ AMND) UTILITY COMPANIES POWER COMPANY: JUMP RIVER ELEC COOP PHONE: UNKNOWN TELEPHONE COMPANY: UNKNOWN PHONE: UNKNOWN 4.1.W. Km Call, P you ft AMEMCAN TOWER° ATC SITE NAME: ROUND LAKE WI ATC SITE NUMBER: 211543 T-MOBILE SITE NAME: Al N0963A T-MOBILE SITE NUMBER: Al N0963A SITE ADDRESS: 11556W LAWRY ROAD HAYWARD,WI 54843 SITE CLASS: GUYED T-MOBILE GENERATOR ADDITION PROJECT SUMMARY SITE ADDRESS: 11556W LAWRY ROAD HAY WARD, W 154843 COUNTY: SAWYER GEOGRAPHIC COORDINATES: LATITUDE:45.99845022 DMS LONGITUDE:-91.27045412 DIMS GROUND ELEVATION: 1427' AMSL I PROJECT TEAM I TOWER OWNER:. APPLICANT.: AMERICAN TOWER T-MOBILE 10 PRESIDENTIAL WAY WOBURN, MA 01801 ENGINEER: ATC TOWER SERVICES LLC 1 FENTON MAIN, STE 300 CARY, NC 27511 PROPERTY OWNER: TOWN OF ROUND LAKE 11556W LAWRY ROAD HAY WARD, W 154843 PROJECT DESCRIPTION THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED EQUIPMENT TO INSTALL A 48KW DIESEL AC GENERATOR. PROJECT NOTES 1. THE FACILITY IS UNMANNED. 2. A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE 3, THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE. 4. NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSAL IS REQUIRED. 5. HANDICAP ACCESS IS NOT REQUIRED. 6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U.S.C. § 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THAT INVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDER CFR § 1.61000 (13)(7). PROJECT LOCATION DIRECTIONS HEAD NORTH ON 1-35 N, TAKE EXIT 183 FOR MN-48 TOWARD CNTY 61/HINCKLEY, 0.2 MI. TURN RIGHT ONTO MN-46 E. 23.4 MI. CONTINUE ONTO W-77 E, 4.0 MI. TURN LEFT ONTO WI-35 N/WI-77 E, 2.2 MI. TURN RIGHT ONTO W-77 E, 26.8 MI. TURN RIGHT ONTO US-53 S, 0.2 MI. SLIGHT LEFT TOWARD US-53 N, THEN MERGE ONTO US-53 N, 0.2 MI. TURN RIGHT ONTO W-77 E/W HOKAH ST, 24.4 MI. TURN RIGHT ONTO W PENINSULA RD, 1.4 MI. TURN RIGHT ONTO CO HWY K, 1.0 MI. TURN LEFT ONTO CO HWY B/CO RD B, 5.2 MI. TURN LEFT ONTO N MCCLAINE RD, 0.3 MI. TURN RIGHT ONTO W LAWRY RD, 0.5 MI. TURN LEFT ONTO ACCESS ROAD. SHEETINDEX SHEET NO: DESCRIPTION: REV: DATE: BY: G-001 TITLE SHEET 0 05/29/24 JMB G-002 GENERAL NOTES 0 05/29/24 JMB C-101 DETAILED SITE PLAN 0 05/29/24 JMB C-501 CONSTRUCTION DETAILS 0 05/29/24 JMB C-502 CONSTRUCTION DETAILS 0 05/29/24 JMB E-601 ELECTRICAL ONE -LINE AND WIRING DETAILS 0 05/29/24 JMB SUPPLEMENTAL SHEETS (2 PAGES) it AMEMCANTQWER° ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468.0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE 0 FOR CONSTRUCTION JMBIns —. 0 In ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: A1N0963A SITE ADDRESS: 11556W LAWRY ROAD HAY WARD, W 154843 SEAL: �+ Ile SA OSHA SHANBHOGUE E-49097 cr_ CARY NC .. 4-L. L.I...,Aiwt V signed ca l I l l i v.31 tut"by Santhosha hanbhog Shanbhogue Date: 2024.05.30 e - rF - •Mobile-- ATC PROJ, #: 14762554 G4 GUST. ID: AlNO963A CUST,#: A1N0963A TITLE SHEET SHEET NUMBER: REVISION: G-001 0 GENERAL CONSTRUCTION NOTES: 1 OWNER FURNISHED MATERIALS, T-MOBILEN"THE COMPANY" WILL PROVIDE AND THE CONTRACTOR WILL INSTALL A. BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUND BUILD/CO-LOCATE ONLY) B, AC/TELCO INTERFACE BOX (PPC) C. ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILDICO-LOCATE ONLY, GC TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION) D. TOWERS, MONOPOLES E. TOWER LIGHTING F. GENERATORS 8 LIQUID PROPANE TANK G. ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING K ANTENNAS (INSTALLED BY OTHERS) I. TRANSMISSION LINE J. TRANSMISSION LINE JUMPERS K. TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITS L TRANSMISSION LINE GROUND KITS M. HANGERS N. HOISTING GRIPS O BTS EQUIPMENT THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE COMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCH MATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB -FRAME FOR PLATFORM, ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES, COPPER -CLAD OR AT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER, CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS AND RUBBER MATTING. REPAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS, MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES AND ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO THE DRAWINGS AND SPECIFICATIONS IT IS THE POSITION OF T-MOBILE TO APPLY FOR PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED PERMITS. 3. ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL. STATE. AND LOCAL CODES, INCLUDING ANSIIEIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS, 4, CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED INSPECTIONS. 6. ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND SITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALL DISCREPANCIES REPORTED TO THE ENGINEER, 7_ DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. B- DETAILS SHOWN ARE TYPICAL: SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS OTHERWISE NOTED, 9. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 10, CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING, ANCHOR BOLTS, ETC. 11. CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS DRAINS, DRAIN PIPES, VENTS, ETC, BEFORE COMMENCING WORK. 12. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILE REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION ANY SUCH REMEDIAL ACTION SHALL REQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING. 13 EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. 14. CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS PROJECT TO MATCH EXISTING PRE -CONSTRUCTION CONDITIONS TO THE SATISFACTION OF THE T-MOBILE CONSTRUCTION MANAGER, 15. ALL CABLEICONDUIT ENTRYIEXIT PORTS SHALL BE WEATHERPROOFED DURING INSTALLATION USING A SILICONE SEALANT. 16. WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET, CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORD IMMEDIATELY, 17. CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE AND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. 18. CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF EACH DAY. 19. CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWER CORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY. 20. CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC) WITH A PDF MARKED UP AS -BUILT SET OF DRAWINGS UPON COMPLETION OF WORK. 21. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDED SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR CONTRACTOR WILL INSTALL ALL ITEMS PROVIDED. 22 PRIOR TO SUBMISSION OF BID CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIRED PERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THE CONTRACTOR 23. CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILE SPECIFICATIONS AND REQUIREMENTS. 24, CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 25. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND AS SHOWN IN THESE PLANS. 26- THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 40 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR SEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW AND APPROVAL. 28. WHEN THE PROJECT SCOPE REQUIRES THE USE OF THE SAFETY CLIMB, THE GENERAL CONTRACTOR SHALL ENSURE THE SAFETY CLIMB IS FREE OF OBSTRUCTIONS, NOT RUBBING ON OR TRAPPED BY ANY INSTALLED CUSTOMER EQUIPMENT, IS VISUALLY TAUT, MEETS MANUFACTURER INSTALLATION SPECIFICATIONS, AND IS FIRMLY SECURED AT ALL CABLE GUIDE LOCATIONS UPON PROJECT COMPLETION. 29, COMPLETION OF PROJECT SHALL NOT OBSTRUCT, TRAP, LOOSEN, OR OTHERWISE CAUSE FAILURE TO MEET MANUFACTURER INSTALLATION REQUIREMENTS FOR THE SAFETY CLIMB. 30. CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITH ALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALL NECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICES SUCH AS WELDING AND FIRE PREVENTION. TEMPORARY SHORING, SCAFFOLDING, TRENCH BOXESISLOPING, BARRIERS, ETC. 31, THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD, ANY DAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HIS WORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS EXPENSE TO THE OWNER'S SATISFACTION. 32 ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIP SHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANY WORK FOUND BY THE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BE REPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS OBTAINED. 33- IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF MATERIALS LISTED HEREINAFTER BY MANUFACTURER'S NAMES AND/OR MANUFACTURER'S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERS AS SPECIFIED. 34, T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED -UP AT THE T-MOBILE WAREHOUSE, NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTED AND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACE THE EQUIPMENT IN OPERATION, READY FOR USE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP_ 35. T-MOBILE OR HIS ARCHITECTIENGINEER RESERVES THE RIGHT TO REJECT ANY EQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH THE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THE EQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO T-MOBILE OR THEIR ARCHITECT/ENGINEER SPECIAL CONSTRUCTION ANTENNA INSTALLATION NOTES: 1. WORK INCLUDED: A. ANTENNA AND COAXIAUHYBRID CABLES ARE FURNISHED BY T-MOBILE UNDER A SEPARATE CONTRACT, THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS, ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PERSONNEL B_ INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND T-MOBILE SPECIFICATIONS. C. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS. D. INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE E. INSTALL COAXIAUHYBRID CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL CONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'S REQUIREMENTS TERMINATE ALL COAXIAUHYBRID CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED. ANTENNA AND COAXIAL/HYBRID CABLE GROUNDING: A, ALL EXTERIOR #6 GREEN GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BE WEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT 9221213 OR EQUAL, B. ALL COAXIAL/HYBRID CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIAUHYBRID CABLE (NOT WITHIN BENDS) ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESE CONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATC ENGINEERING IMMEDIATELY FOR CORRECTION OR RE -DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING OR ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. AL AMERMCAN TOWER• ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED, ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER 15 STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION REV. DESCRIPTION BY DATE /0\ FOR CONSTRUCTION JMB 05/29/24 0 n ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: AlN0963A SITE ADDRESS: 11556W LAWRY ROAD HAY WARD, W 154843 SEAL: ``�,,�������►<<�� I I rrrrr►rrr�r, 1 ��SCONS SANTHOSHA •': SHANBHOGUE E-49097 oCARY W ,n NC for Digitally Signed: 2024-05-30 IF soMobilee ATC PROJ. #: 14762554 G4 CUST.ID: AlN0963A OUST. #: A1N0963A GENERAL NOTES SHEET NUMBER: REVISION: G-002 0 SITE PLAN NOTES: 1. THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2. ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS. 3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. 4. CONTRACTOR SHALL INSURE THAT ALL WORKING SPACE REQUIREMENTS ARE MET PER APPLICABLE CODES AND MANUFACTURER SPECIFICATIONS. 5. CONTRACTOR IS RESPONSIBLE FOR INITIAL FILL OF FUEL TO 90 OF TANK CAPACITY. 6. ABOVE GROUND CONDUITS NEED TO BE SUPPORTED/FASTENED PER NEC 344, NEC 352, AND PER ATC CONSTRUCTION SPECIFICATIONS. 7. THE FOLLOWING SIGNS SHALL BE INSTALLED AT TENANT SERVICE MAIN DISCONNECT PER NEC 702.7. 7.1. "CAUTION: TWO SOURCES OF SUPPLY STANDBY GENERATOR LOCATED OUTDOORS" 7.2. "WARNING: SHOCK HAZARD EXISTS IF GROUNDING ELECTRODE CONDUCTOR OR BONDING JUMPER CONNECTION IN THIS EQUIPMENT IS REMOVED WHILE ALTERNATE SOURCE IS ENERGIZED" 7, ALL CONDUIT TO BE DIRECT BURY. ANY ABOVE GROUND CONDUIT SHALL BE RIGID METAL. ALL CONDUIT TO BE STUBBED THROUGH SLAB INTO BOTTOM OF GENERATOR. RODENT CONTROL AROUND GENERATOR ENVELOPE: 1, INSTALL ALL PROVIDED SEALS, PLUGS, COVERS, ETC. IN GENERATOR AND FUEL TANK ENVELOPE. SEAL ALL REMAINING OPENINGS (EXCEPT NORMAL VENTING) WITH RODENT FOAM SEALANT. NO OPENING SHALL BE LARGER THAN 1/4 INCH ANY DIMENSION. 2. SEAL ALL CONDUITS INCLUDING CONDUITS ENTERING GENERATOR EQUIPMENT, BOXES, ATTACHMENTS, ETC. WITH RODENT FOAM SEALANT. 3. SEAL ALL CONDUIT ACCESS OPENINGS THROUGH CONCRETE PAD WITH CONCRETE. EXISTING T—MOBILE EQUIPMENT ON A 7 10" X 8'-3" PLATFORM W/ 12' X 16' GROUND SPACE 1 PROPOSED UNDERGROUND 5 CONDUITS AND SIZES PER ONE LINE PROPOSED GENERATOR E-STOP 2 PROPOSEC 5 AUTOMATIC TRANSFER SWITCF PROPOSED H-FRAME C-50 CH I� I, I PROPOSED NEMA 3R JUNCTION BOX SIZED PER NEC 314. TO SPLICE FEEDER FROM PROPOSED ATS TO EXISTING TENANT PANEL. ,IB ` 46KW CZIRAC AC GENERATOR 1 s ON 4' X 9' CONCRETE PAD AND GROUND SPACE. li•li[] 60 C•50 ANCHOR GENERATOR WITH SIMPSON WEDGE ANCHORS OR APPROVED EQUIVALENT. (SEE NOTE 5) DETAILED SITE PLAN GRAPHIC SCALE N 0 2.5 5 I ( IN FEET) 1 UNIT = 5 FEET 4'-10" X 5,-4" PLATFORM EXISTING T—MOBILE METER AND SERVICE MAIN DISCONNECT it AMEMCAN1rQVVER° ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 466-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION, REV. DESCRIPTION BY DATE ❑0 FOR STRUCTIDNJ JMB 05/29/24 ❑ _ ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: Al N0963A I SEAL: SITE ADDRESS: 11556W LAWRY ROAD HAY WARD, W 154843 j1111111111111111►11 SANTHOSHA SHANBHOGUE E-49097 o CARY NC S NA` 11111111111111 11,, Digitally Signed: 2024-05-30 T--m 1. ATC PROJ. #:I 14762554_G4 CUST.ID: AlN0963A CUST #: AlN0963A DETAILED SITE PLAN SHEET NUMBER: REVISION: C-101 0 9'.0• 94 @ 6" E. W 3/4" CHAMFER R1 EXISTING 6" EXISTING CRUSHED COMPACTED FILL STONE OR GRAVEL PAD NOTES: (SEE NOTE 2) 1. SUBGRADE AND FILL SHALL CONSIST OF CLEAN SOIL. DELETRIOUS MATERIAL AND ORGANICS SHALL BE REMOVED. 2. MECHANICALLY COMPACT FOOTPRINT OF PAD PLUS 2' PERIMETER USING A MECHANICAL PLATE TAMPER, MIN 3 PASSES. SEE ATC MASTER SPEC 312000 ACCESS ROAD AND EARTH WORK. 3. USE GALVANIZED HILTI EXPANSION ANCHORS OR, APPROVED EQUAL, FOR EQUIPMENT ANCHORAGE. 4. FOR SIZE AND LOCATION OF ANCHORS AND OTHER REQUIREMENT, SEE EQUIPMENT VENDOR DRAWINGS. (D GRAVEL PREPARATION SCALE: N.T.S. PAD NOTES: 1. SUBGRADE AND FILL SHALL CONSIST OF CLEAN SOIL. DELETERIOUS MATERIAL AND ORGANICS SHALL BE REMOVED. 2. COMPACT SUBGRADE TO 95%. 3. USE GALVANIZED HILTI EXPANSION ANCHORS OR, APPROVED EQUAL, FOR EQUIPMENT ANCHORAGE, 4. FOR SIZE AND LOCATION OF ANCHORS AND OTHER REQUIREMENT, SEE EQUIPMENT VENDOR DRAWINGS. 5. DETAIL FOR ILLUSTRATIVE PURPOSES ONLY, MODIFY PER GENERATOR MANUFACTURER SPECIFICATIONS TO ACCOMMODATE STUB UP. I CONCRETE PAD FOR GENERATOR SCALE: NOT TO SCALE rtvrvo�u ,ENERATOR 'ROPOSED /2"0 SIMPSON STRONG -BOLT® 2 VEDGE ANCHOR OR EQUIVALENT V/ OVERSIZED FLAT WASHER. 3C TO INSTALL PER ICC# ESR-3037 PROPOSED CONCRETE PAD DRILL MINIMUM 1/2"0 HOLE X 4 1/8" DEEP AT ANCHOR LOCATION NOTE INSTALL SIMPSON STRONG -TIE® STRONG -BOLT® 2 WEDGE ANCHOR(S) STRICTLY PER INSTALLATION INSTRUCTIONS INCLUDED WITH PRODUCT OR FOUND ONLINE AT WWW.STRONGTIE.COM. PROPER INSTALLATION IS CRITICAL FOR FULL PERFORMANCE. GENERATOR ANCHORAGE DETAIL J SCALE: NOT TO SCALE AL 7 AMEMCAIV TOWS R® ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 46"112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED, ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED, NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE A FORCOMSTRUCTION JMB 05/29/24 A A ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: A1N0963A SITE ADDRESS: 11556W LAWRY ROAD HAY WARD, W 154843 SEAL: �L111111111111i1�1 SANTHOSHA SHANBHOGUE - E-49097 o CARY ,7k- rrrF`ffZIV �0 N A L�����`. 111111111 Digitally Signed: 2024-05-30 'F - -Mobile-- ATC PROJ. #: 14762554 G4 CUST.ID: AlN0963A CUST. #: AIN0963A CONSTRUCTION DETAILS SHEET NUMBER: REVISION: C-501 0 EXISTING VARIES MATCH TO EXISTING OR FINISH TO PROPOSED CAP — 3'-0- � FA A QR7kR� PIPE ---------- — GRADES (SEE PLAN) +,oaaetnvp°opaoo°va°o°cpr°o°pn°o ' 11T 3" STD GALVANIZED opnn a°aOo°°°oipv°°aeo °ao L�F�n` PIPE ea°ap °°°coca T6o°°Daa vo • rv� WARNING TAPE Z opn°pnp°e°° °o°a°a �o� `v ❑c° Qaeoop°°vc 000� boo TRENCH UNISTRUT/H-FRAME oa 9°oe pO� pe0°°poo a °e�L EXTENSION °np oco° CLEAN COMPACT FILL 0 (TO BE FIELD LOCATED) o°°°papo � on°�pBDbtropOOOp� 060°°°�.... a°°vopO°aaptrv� a°°sao°N> ooptre°°oop°e°e° SCH 40 PVC CONDUIT (POWER CONDUIT) CLEAN SAND SUITABLE FOR CONDUIT BEDDING SCH 4D ALARM. CONTROL WIRING & 12. "" COMMUNICATIONS WIRING (TYP.2) SCH 40 PVC CONDUIT 3" MIN. 3" MIN. (POWER CONDUIT) TRENCH NOTES: 1. IF FREE OF ORGANIC OR OTHER DELETERIOUS MATERIAL, EXCAVATED MATERIAL MAY BE USED FOR BACKFILL. 2. IF NOT, PROVIDE CLEAN, COMPACTIBLE MATERIAL. COMPACT IN 8" LIFTS. REMOVE ANY LARGE ROCKS PRIOR TO BACKFILLING, CONTRACTOR TO VERIFY LOCATION OF EXISTING U/G UTILITIES PRIOR TO DIGGING. 3. IF CURRENT AS -BUILT DRAWINGS ARE NOT AVAILABLE CONTRACTOR SHALL HAND DIG U/G TRENCHING. 4. CONFIRM SPACING AND DEPTH WITH NEC OR LOCAL CODE REQUIREMENTS 5. AC POWER CONDUITS MUST BE 3" MINIMUM FROM OTHER AC CONDUITS AND 12, MINIMUM FROM COMMUNICATIONS CONDUITS GENERATOR SERVICE CONDUIT TRENCH SCALE: NOT TO SCALE COMMUNICATION CONDUIT TO GENERATOR EXOTHERMIC WELD COLD GALVANIZE AFTER COOLING 1" CROWN #2 SBTC GROUND CONDUCTOR TO GROUNDING ) i ELECTRODE CONDUCTOR LOOP 12"0 CONCRETE FOOTING (PRE -CAST WHERE ALLOWED BY JURISDICTION) UNISTRUT PIPE/CONDUIT CLAMP P1119 OR P2558-35 (GALV.) (TYP.) FOLLOW MANUFACTURER RECOMMENDATIONS FOR BOLT TORQUE SECTION A -A TRANSFER SWITCH (SEE NOTE 7) ELECTRICAL CONDUITTO Z POWER SOURCE r ELECTRICAL CONDUIT TO GENERATOR H-FRAME NOTES: 1. IF IT IS NECESSARY TO EXTEND THE H-FRAME, AN ADDITIONAL POST SHALL BE REQUIRED. 2. PROPOSED UNISTRUTS TO BE FIELD CUT AND SHALL NOT EXTEND MORE THAN 6 INCHES BEYOND THE LAST POST. 3. SPRAY ENDS OF UNISTRUT WITH COLD GALVANIZING SPRAY PAINT, ALLOW TO DRY, THEN COVER WITH RUBBER PROTECTIVE CAPS FOR SAFETY. 4. UNISTRUT TO BE CUT FLUSH WITH NO SHARP OR JAGGED EDGES. 5. ALL PROPOSED HARDWARE TO BE MOUNTED AND GROUNDED PER MANUFACTURERS SPECS 6. ALL ITEMS ARE PROPOSED UNLESS OTHERWISE NOTED. 7. LAYOUT H-FRAME & PROPOSED EQUIPMENT EXACTLY AS SHOWN TO ALLOW FOR FUTURE EQUIPMENT. ANY DEVIATIONS MUST BE APPROVED BY ATC CM, IN WRITING, NO EXCEPTIONS. 8. FOOTINGS SHALL BE ONE OF THE FOLLOWING: USS POLECRETE STABILIZER SYSTEM, PRECAST CONCRETE (WHERE ALLOWED BY JURISDICTION) OR CAST IN PLACE. FOR PRECAST FOOTINGS, CONTRACTORS SHALL THOROUGHLY COMPACT THE PERIMETER (2' MIN) OF FOOTING WITH MECHANICAL PLATE TAMPER. H-FRAME SCALE: N.T.S. AME MOAN TOWER• ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069.11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. REV. DESCRIPTION BY DATE A0 FOR C,Qoj7RUCTlON JMB _Q�M A 0 ATC SITE NUMBER: 211543 ATC SITE NAME. ROUND LAKE WI T-MOBILE SITE NAME: AlN0963A SITE ADDRESS: 11556W LAWRY ROAD HAY WARD, W 154843 SEAL: 111 I I I I I► r r rrr�� tit CSC O NS �•, '� .�A'` SANTHOSHA SHANBHOGUE E-49097 r CARY w '.o NC �� I U NIA IX- Digitally Signed: 2024-05-30 T - -Mobile-- ATC PROJ. #: 14762554_G4 CUST.ID: AlN0963A CUST.#: AlNO963A CONSTRUCTION DETAILS SHEET NUMBER: REVISION: C-502 0 THIS DESIGN ONLY APPLICABLE TO 240V 1¢ UTILITY SERVICE. FIELD VERIFY UTILITY SERVICE AND IF NOT 240V 10, HALT CONSTRUCTION AND RE -PROCESS FOR RE -DESIGN EXISTING METER SOCKET WITH KWH TENANT CIRCUIT BREAKER I SERVICE ENTRANCE RATED. l 20OAl2P I UN —TERMINATE EXISTING AT TENANT PANEL, PULL — BACK INTO JUNCTION BOX MAIN AND SPLICE AS SPECIFIED. VERIFY GROUND PER NEC 14"X20"X6" JUNCTION 1 BOX. SPLICE OR FEED THROUGH AS REQUIRED (SEE NOTES 2 AND 3) TERMINATE GENERATOR SUPPORT CIRCUITS ON GENERATOR WIRING TERMINAL STRIP. VERIFY OR INSTALL AS FOLLOWS: 1. BATTERY CHARGER- PRE -WIRED ON ONE 120V CIRCUIT. 2. BLOCK HEATER - HARD WIRED 120V CIRCUIT EMERGENCY POWER OFF (SEE NOTE 4) GROUND PER NEC J , r 48kW 10,1201240V, 3W, OPTIONAL fi STANDBY GENERATOR SEE TELCO AND POWER JOINT TRENCH CONDUIT ON C-501 GENERATOR INSTALLATION NOTE: — GENERATOR MECHANICAL WELD. CONNECTED INTERNALLY TO CHANNEL FRAME WITH DOUBLE LUG, SS HARDWARE. #2 SBTC GROUND CONDUCTOR, EXOTHERMIC WELD TO GROUND RING. COLD GALVANIZE AFTER COOLING. 343/0 AWG, #6 AWG G, IN 2" C INSTALL GENERATOR AND TRANSFER SWITCH WITH ALL SUPPLIED ACCESSORIES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS AND _ SPECIFICATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO, ACCESSORIES FOR THE EXHAUST SYSTEM, FUEL SYSTEM, ENCLOSURE INTEGRITY (CAPS, PLUGS, COVERS, ETC.), ELECTRICAL CONNECTIONS, AND GROUNDING CONNECTIONS. PROPOSED 200A, 2P, 240V GENERATOR GROUNDING AUTOMATIC TRANSFER 2 SCALE: NOT TO SCALE SWITCH WIRED AS A NON -SEPARATELY DERIVED SYSTEM (TYP) �— 3-#3/0, (1) #6 AWG G, 2 C COMMUNICATIONS CABLE IN 3/4" C 'Ni P 2 NIP TENANT PANEL EXISTING (4) #12 CU AWG THWN PROPOSED 3/4" SSC (1) #12 CU AWG G CONDUIT FROM IN 3/4" C GENERATOR TO SSC FROM GENERATOR BLOCK FOR COMMUNICATIONS ONE -LINE NOTES: HEATER AND BATTERY CHARGER 1. CONNECT CPS PER HTS OWNERS MANUAL -SECTION 3.11.2 INSTRUMENT PACKAGE 2. SPLICE WITH "POLARIS" TAPS OR APPROVED EQUAL, SECURELY WRAPPED WITH COMMERCIAL GRADE NYLON ELECTRICAL TAPE AFTER INSTALLATION IS COMPLETE. 3. UTILIZE EXISTING ENCLOSURES FOR SPLICING (PER NEC 312.8) OR INSTALL NEW JUNCTION BOX AS APPLICABLE PER SITE CONDITIONS AND CODES. SIZE JUNCTION BOX AS PER NEC 314.28 4. EMERGENCY POWER OFF PUSHBUTTOM IN WEATHERPROOF ENCLOSURE FOR REMOTE SHUTDOWN OF GENERATOR ENCLOSURE. FURNISHED BY GENERATOR MANUFACTURER AND INSTALLED BY CONTRACTOR. CONNECT TO Y TERMINALS LOCATED NEAR T132 VIA 2#18 AWG WIRES IN 1/2" LFMC. 5, THE PROPOSED GENERATOR COMES CONFIGURED BY THE MANUFACTURER, IS UL LISTED, AND IS EXPECTED TO SHIP WITH EITHER A 20OAl2P OR 175A/2P MAIN CIRCUIT BREAKER INSTALLED BY THE MANUFACTURER. 1 ELECTRICAL ONE -LINE DIAGRAM SCALE: NOT TO SCALE AL AMERICAN TOWER° ATC TOWER SERVICES LLC 1 FENTON MAIN SUITE 300 CARY, NC 27511 PHONE: (919) 468-0112 4069-11 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED, NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON -SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION, REV. DESCRIPTION BY DATE QO FOR aNSTRUCTION JMB Obi 2 0 A A ATC SITE NUMBER: 211543 ATC SITE NAME: ROUND LAKE WI T-MOBILE SITE NAME: AlN0963A SITE ADDRESS: 11556W LAWRY ROAD HAY WARD, W 154843 SEAL 0 %111111101111111. O �•` SANTHOSHA ''s SHANBHOGUE E-49097 CARY All NC A' A L' IIIIIIIII�� Digitally Signed: 2024-05-30 1� -Mobile- ATC PROJ. #: I 14762554—G4 CUST.ID: A1N0963A OUST. #: I AlN0963A ELECTRICAL ONE -LINE AND WIRING DETAILS SHEET NUMBER: REVISION: E-601 0 RD048 I 3-4L I 48kW INDUSIHIAL DIESEL GENEHAIOH SEr Standby Power Rating 48 IcW, 60 Hz CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details. @ UL2200, UL508, IJL489, UL142 UPI CSAC222 VDIN BS5514 and DIN 6271 SAE J1349 L�J NFPA 37, 70, 99 r4P" t : r ISO 30461 8528, 9001 jVjF NEMA IGS1, ICS10, MG1.250, IGS6, AB1 4,...wo.rsw4a Mn. ANSI/FFF C6241 GENERAL I INDUSTRIAL r..g Wfa P.P_ * POWERING AHEAD For over 50 years, Generac has led the industry with innovative design and superior manutacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, including alternators, enclosures and base tanks, control systems and communications software. Generac's gensets utilize a vide variety of options, configurations and arrangements, allowing us to meet the standby power needs of practically every application. Generac searched globally to ensure the most reliable engines power our generators. We choose only engines that have already been proven in heavy-duty industrial application under adverse conditions. Generac is committed to ensuring our customers' service support continues after their generator purchase. RD048 I 3AL I 48kW INDUSTRIAL DIESEL GENERATOR SET OIMFNSIONS ANO WEIGHTS` Weights and Dimensions 48kW Fuel Consumption Fuel Tank Gross Total Capacity 240 U (Run Hours Based on Netet _-sUs,able Capacity) 206 Run Hours 100% Load 52 Run Hours 75% Load 67 Run Hours 50% Load 96 Rated Load Sound Output al 23f1- dB(A) GENERAL'' INDUSTRIAL 111111I j :��• �rrasl "at6 rr � de„� �rL�o•,i n%rae ".1.m� n si[ w�M,� ere Is P�'^^mY PaP�r ail Aes:� cmz.l! a Serss PoxQSy�c t�emNe Dede b aeYisd imhl�,cn Lvri� Ge P. erSy.h_ k. I POE..B I A.*ea. l531" .4 x: P 1?62) SU4811 C2016uw Pawn SVv 1. N n ft -.,.d w urcac.am. arz atjeltlo I-V. w0r '. rases Pn. 6- a O&W116 1 GENERATOR SPECS SCALE: N.T.S. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDE BY REQUEST OF CUSTOMER WITHOUT EDIT, SUPPLEMENTAL SHEET NUMBER: REVISION: R-601 0 GENERAC & Automatic Service and Non -Service Rated Transfer Switches Automatic Transfer Switches OEM - Models: RXSG10OA3 R)(Se N150A3 RXSC20OA3 W. W20OA3 Description This series of Generac Aummalic Transfer Switches is designed for use with single phase generaEors that Id®e an Evolution- of Nexus- Conunller. The 100 and 200 Amp open transition switches are av2JW* in single phase in both service ec ign ent rated and non -service equipment raced confog<IrMions. The 150 Amp open oarriton switch is only available in a service rarev equipment canfguration. Standard Features Service rated (RXSW) Genera Automatic Transfer Switches are housed in an alumirum NEAMA Type Ski enclosure*, with electior=-Aly applied and baked powder paint TFe Heavy 13xiy Gerel sa Contacfat r, an ETL fecopw2d device, designed for years of service. The controller attire generAw handles al the firr,iq, sensing, exercising funcWrin. and fiat ;fir : ommands. A I swg &-m are covered by a five year limited warranty. 1 Iran-:,ervice rained (RKSC) swkhes are housed in a sal enclosure. Load Management Technology Thnxo the use of fhe integrated Smart K Module (SACfIA, these imxt'Es have the capability to manage up to four indnridual HVAC (24 VAC eontrrcled) beads wth no acditonal hardware. When used in tandem v& eameal 5matt Management Modules, a foam ol eIjht more loads can be managed, providingthe most in= aft,.r efficient power management options available. CENERAC`SPECS SCALE: N.T.S. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT SUPPLEMENTAL SHEET NUMBER: REVISION: R-602 0