HomeMy WebLinkAbout024-841-10-4401-SAN-2024-049 PAGE 1 OF 4
In-Ground Gravity Plan
Index & Cover Sheet
Component Manual Design References:
In-Ground Soil Absorption for POWTS Version 2.1 (May 2022-2027)
Pg 1 of 4 Index&Cover Sheet
Pg 2 of 4 Plot Plan
Pg 3 of 4 Dispersal Area Cross-Section & Plan View
Pg 4 of 4 Management Plan
Attachments: Enclosures:
POWTS Application for Review
Soil Evaluation Report&Site Map
Project Name/Description
Owner Name(s): ���'�=�'"- �� P1 i3 F L1-l. Phone: - -
OwnerAdd�ess: '�548� �,�; ik�✓�� �3 i�uy�.�;� WL Zip: 5uvu�>
Project Address: ��'��'3�� ��'> '�w" E> 1��y v-;� �s
Govt.Lot: 1/4 of 1/4,Section 1� ,T ��� N-R �� E Q or W�
Township: �u���. � 15i County: S���yzr
Project Parcel ID#: �24����� �a��v�
Designer Information
DesignerName: Dan Burch Phone: �15 _416 _1642
Designer Address: N5921 Cty Hwy K Spooner WI Z�p; 54801
E-maii: burchplumbinginc@gmail.com ��� �.«,� ,, � �,._r�._,
License Number: 253808
Remarks:
Signature: Date: �� L�— �-I
riginal signature required on each submitted copy.
CHECK BOX AS APPLICABLE. CHECK BOX AS APPLICABLE.
� SOIL EVALUATI�N Scale: 1�� = so� � SYSTEM PAGE 2 OF
SITE MAP ° � 45 �o
PLOT PLAN
PROJECT NAME: i� •
p7 5z DESIGN FLOW: `1�(J GPD
�� e ���9 r �� Attach design flow calculaEions for commercial plans.
PRo�Ecr,aoDREss: Pipe Materfal /ASTM Standarcl (Tables 384.30�8 384.30�5)
BM Symbol: �- BM Elevation: �U�' FT � Santtary Sewer:.ILk yU �t-/
;� Force Main; /
BM Descriptlon: �+'�t . h lJe»�.1 t CQ7 n�r �y (�c.i�
Slope Gradlent(�k) �ndicate north by IMPORTANT:
of Tested Area: �Nell SymCol(ff applicabie); Q drawing an arrow Show ground elevation contours at suitable intenrais.
on the approprfte 19�e.
� ��
, — t�v " — -- �-#-�;,US�,
�--`' . �� 1 . Q �
� � �
� ` ��;33 w `�C ��� �l ��l .�
�� �Ec�.�ti<� � u Wz;`��� (-=
� ��,,.�
� � P6 I y I�� ���
�� �ku+�n:.,�S
��� ����
h1 r. ' a
� � ��
�
' t
( ��
��
��� .�
���' .s
�
�
IN-GROUND DOSED-GRAVITY DISPERSAL AREA
Uniform Elevation Trenches with Quick4 Standard-W Chambers
3-ft Trench (down-sizing credit)
�
m1n.12° �(pICAL TRENCH
SOIL COVER «P+���
CROSS SECTION VIEW
i r�
min.trench (No Scale)
depm .
(typlcal) •; a '
e
• ,. •' . .d a:
L ��� ''• e, �. .
r (tyP��l ':'a , . .
„ � a.. . ;' Provide minimum 3 ft
. • '° (���� separation between trenches.
System Elevation = �r ft
(typical)
Quick4 Standard-W
w/End Cap Observatbn Pipe
�typ���� (Show location of inlet/outlet pipe connection on plan view.) �ryP��� TYPICAL TRENCH
Install per manufacturers
��n��h��s. PLAN VIEW
�,/ (No Scale)
��F�'�*�s*'��a�+�4r!��wl� � /� — — — �rvr��m+r����s'�'�`•r���'��
— — — — — — — — — —
'� �� � . �
{f :u �. � r � ;� i�, A= 3.Ofl
�M�an�,��n�;�r,#���r�ill�i� ��ra � ���r��,.�.�!a.a���t��+.� ih'Pipl)
�- -`- - - - - - - - - - �� �� - - - �f- -- - - - - - - - - �
F- B = ft D
�typ���� Quick4 Standard-W Chamber m
INSTALL PER TRENCH: �ryp���} W
(mftl by Infiltrator Systems,Inc.) O
� (`j InstaB pursuant to manufacturer's instructions.
� Quick4 Std-W @ 20 ftz EISA/chamber= �L ftZ T�
+ � Pairs of end caps @ 6 ft2 EISA/pair= � ftZ �
= Proposed EISA per trench= �L � ft2 Required Infiltration Area= ��� ftZ Distribution Method:
x L trenches = Proposed Total EISA= ��� Z �Z branched manifold
.�
��
PAGE40F4
In-ground Gravity Management Pian
IMPORTANT:
The owner of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant to
requirements of SPS 382-384,Wisc.Admin.Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code,this system shall
be considered a human health hazard if not maintained in accordance with this approved management plan.
Furthermore,all inspection and maintenance activities shall be performed by a registered POWTS Maintainer in
accordance with SPS 383.52(3),Wisc.Admin.Code.
Maximum Disaersal Area O�eratinA Limits:
Design Flow= �`�U gpd; BODS<_220 mgL"'; TSS 5150 mgL''; FOG<_30 mgL"'
Insaectlon Checklist INSPECT EVERY 3 YEARS
o type of use
o age of system
o nuisance factors(i.e.odors,user complaints,etc.)
o mechanical malfunctlon(i.e.,pumps,valves,switches,floats,etc.)
o material fatigue(i.e.,leaks,breaks,corrosion,etc.)
o solids volume in anaerobic treaVnent tank(s)and any distribution appurtenance(s)(i.e.,distribution/drop boxes)
o neglect or improper use(r.e.,exceeding design capacities,prohibited activities,etc.)
o extent of ponding in distribution cell prior to dosing
o dosing irregularities-if applicable(r.e.,pump re-cycling,float switch settings,etc.)
o electrical components-if applicable(i.e.,wiring,connections,switches,controls,timers,alarms,etc.)
o distribution lateral or lateral orifice plugging (measure lateral distal pressure—compare to design specification)
o surface discharge of effluent or sewage back-up into structure served
Maintenance Checklist MAINTAIN EVERY 3 YEARS(or when necessary)
o Septic and dose tank(s)shall be pumped by a certified septage servicing operator licensed under s.281.48 Wis.
Stats.when the volume of solids in the tank(s)exceeds one-third(1/3)the liquid volume of the tank(s)or
as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin.Code.
o Effluent fliter(sl shall be inspected every 3 years and shall be deaned when necessary to remove any
accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12
months.
System maintenance reports shali be submitted to the proper local government unit in accordance with
SPS 383.55 Wlsc.Admin.Code. Report any component failure or malfunction to:
Name of individual or company: Dail BUfCI1 Phone: 715.416.1642
�ocal government unit: SaWy2�COUnty ZOtllflg Phone: 715.634.8288
Local govemment unit address: 1061 O M81f1 St. #49 ZiP: 54843
Any defective part of this system shall be repaired,replaced,or removed pursuant to SPS 383.51(1),Wisc.Admin.
Code.Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc.Admin.Code.
No product for chemical or physical restoration of the POWTS may be used uniess approved by the department in
accordance with SPS 384,Wisc.Admin.Code.
Continaencv Plan
In the event that any failed treatment component of this POWTS cannot be repaired,it shall be replaced pursuant to
a plan submitted to the appropriate agency for review and approval. A failed int,7round dispersal component may be
abandoned and replaced by a code-complying dispersal component in a pre-determined area of suitable soils.
Svstem Abandonment
If use of this POWTS is discontinued,it shall be abandoned in accordance with SPS 383.33,Wisc.Admin.Code.