Loading...
HomeMy WebLinkAbout002-840-16-3309-LUP-2001-343 �� �DO ���,'e-1 G1d� 5c, �e � ,�--- . a° �_ � Application for Land Use Permit �SO o o � County of Sawyer � � PO Box 676 -Hayward WI 54843 � 715/634-8288 � The undersigned hereby makes application for a Land Use Permit and agrees that all work ` shall be done in compliance with the requirements of the Sawyer County Zoning Ordinance �• 1 and the laws and regulations of the State of Wisconsin.CONSTRUCTION MAY NOT � BEGIN UNTIL THE PERMIT IS ISSUED. PRIPIT—USE BLACK INK OR PENCIL � ti a � /ry / / N. k �' � .!� ' v � :..��l�✓ (:✓ii7/l,t ic'��'� �Z[ (lr.l�-f.�l (,ilc�./_LA�� o- Owner Builder ° o � ' �/� �4 �' � 7 b'�/ .f/',�.-, s .�� ��. �'�3 y� i�i �.�,� � Mailing Address Mailing Address � �,K , �✓l s v� ��, i1�/l � �� sy��;r Ciry, tate,Zip Ci State ip �iS-� G 3 y- s�z� 7i��- yss-ayz� Daytime Phone Daytime Phone � Building Land Use � �(New ( )Filling Zone District (�—� � ( )Addition ( )Dredging O Alteration (�Grading ov c f Lot Size o O Moving On O�noJ s F � ( ) ( ) ClviUe �rki Acres � ��� c � �n v �- �«�,�,-f' � � " Primary Structure Acc�ssory Building Addition � � ( )Dwelling ( )Garage-attached/detached ( )Deck � o ( )Year round ( )#of car stalls ( )Porch � � ( )Seasonal ( )Storage Building ( )Enclosed � (�Frame built on site O Screenhouse O Living room � ( )Modular/manufactured ( )Greenhouse ( )Kitchen �' ( )Mobile/manufactured ( )Other ( )Bedroom � ( )Other primary structure ( ) ( )Relocate/enlarge � � ( ) ( ) ( )#ofnew � � Gu ; � .� T of Construction (�rame ( )Log ( )Pole/metal ( )Block ( )Concrete C � ( )Other '��° � (� JU a Construction Cost$ Z•> � ��� . � Vol (r;U� Pg /�� of Deed Certified Soil Test# ��rr � CSM Vol Pg Sanitary Permit# �1 — o�G� z Plat Envelope �r� ° � Condo Vol Pg Year Installed � `� Aff of ex septic V P Owner When Installed: � ,j���b� 2< 7-ar-�cr =' a��� �` Application for Land Use Permit—Page 2 Describe Construction:List dimensions of each structure,story,addition,or alteration. #1. #2. (�arC� #3. #4. Size�ft.wide /�� ft.wide ft.wide ft.wide' �ft.long �l� ft.long ft.]ong ft.long Floor area ���C> sq.ft. -7 3�' sq.ft. sq.ft. sq,ft. Hgt.from gade -��• to peak ft.hgt. ft.hgt. ft.hgt. Stories o? stories stories stories #of bedrooms —G— reaz lot line or waterline of lake/river In the box sketch in: Location and size of all existing and proposed structures. Location of septic system. Indicate distance to: Waterline/Wetlands Road Lot lines Septic system/privy Wel1 Distance behveen structures. Indicate North. Fire Number: ����'. �'�. � � S gnature of Awirer ������ r� The above certifies that the listed information and intentions are true and coaect.The above person/s/hereby give permission for access to the proper[y for onsite inspection. -------centerline of road------- IssueDate 8/6/O1 ExpireDate 8/6/02 Office Comments: C./1L'�C � / ,ll�i��9 Signature ofZoning Administrator �6.1 � _� i ., � � � . ; � i I I e � . � � � � � � I i i � -__ --.._ _-- _.--- ----_—.--- . _.._ . . . _._ : _ _ . ._ _.. . _. . . : � � ; � I , I 40,(� � ��`� �. \•7. �." �t_� {�� � 4 n� � �.�',1 , •_0' :� '3 ' ; � ��;, I t u' ;� �'i � � � _ I i i , I 7 -- - --- ----- - -- --- -- - . - _ _-- _ . \ 1 ' _—' I �1- ..� \�J� ill � � —1 n � i .��,1 �� ' � �I I i, I IU.� � „" � � — �,: ��r, ��� I �_ . � �, , � tr�� _ \:�, �,�. -�.I , I � � --------- `a �r ; , �--- - - ���� , � - � ; i I � ,_ � .r:, � , , i ' .. ! r---- .�,' +� , � � , I -- �J.�� i I � ; i , 1 � - ____ -_ __ __ _ . - _ __ — T-- —�--- - ------- -- i � � \l , .� (.3 � ti:� I I K `o' ' 1 � .11. , / � � ;. .. I �--� i ; .II.Y ! i �� ' � � , �___ __-. . , - --- - - ; �-;,, ; ti _, � � '�_ � ' `�� � _ �.ol. !t� i � � I� _ I , ,.% � --- I `� � ' I I � �� �,�j 7'� '•r�' �') I � r--- �_ � � i ,4p i' ' ���.� � I�-- -- _-- - ----__ _- _ -- -- -__�_--- I ��: -; ;. -/3 -,".. L I � •I I.6 ,�',� = . _� . .'�_ . _�✓ .��� t,' ` ', --, . -- ;'�.J \ Nvisconsin Department of Commerce 31, 2001 CUST ID No.264953 PHILIP BROUSSARD ARCHITRON 3338 UNIVERSITY AVE S STE 400 ST PAUL MN 55414 Safety and Buildings 10541 N RANCH ROAD HAYWARD WI 54843 TDD #: (608) 264-87. 1 www.commerce.state.wi.us/sb www.wisconsin.gov Scott McCallum, Governor Brenda J. Blanchard, Secretary AT77V: Buildings & Structures Inspector MUNICIPAL CLERK TOWN OF BASS LAKE RR 2 BOX 2139A HAYWARD WI 54843 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 07/31/2003 Identification Numbers Transaction ID No. 655916 SITE: Site ED No. 631882 INDIAN COUNTRY COMMUNICATIONS Please refer to both identification numbers, CTH K above, in all correspondence with the agency, TOWN OF BASS LAKE, 54843 SAWYER COUNTY FOR: OBJECT TYPE: BUILDING REGULATED OBJECT ID NO.: 798937 CLASS OF CONSTRUCTION: 8 WOOD FRAME -UNPROTECTED; NEW PLAN; 5,760 PROJECT SQ FT; 1 STORY BLDG; UNSPRINKLERED; OCCUPANCY: BUSINESS, MERCANTILE/COMMERCIAL The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: • COMM 50.07(2) This project involves a building with a volume in excess of 50,000 cubic feet. The plans must ... be.signwd sealed -and dated.by the registered professional who prepared them. The revised plans received with your application were not signed, sealed and dated. A signed, sealed, and dated letter from the designer of record indicating that he has reviewed the revised plans is included and considered part of the submittal. • COMM 50.12(4)(a) The plans reviewed do not show the anchor bolt layouts and details. Anchor bolt plans and details are shown in the submitted structural calculations, and are to be installed per those details. • COMM 50.12(4)(b) Submit one (1) set of building envelope calculations with the HVAC Application for Review in accordance with COMM 63.01 on forms or computer printouts approved by the department. When the total building volume exceeds 50,000 cubic feet, the calculations shall be stamped, signed, and dated by the professional who prepared them. The most recent version of ComCheck-EZ, a computer program, may be used to create documentation. The documentation can then be submitted for demonstrating building envelope compliance. Contact 1-800-270-2633 for additional information. • COMM 54.08(1)(b) All exit stairs in this building are not enclosed, or the enclosures are not complete to an outside exit door. The required shortened exit distance on the floor levels affected by the open stairs has been met, and stair enclosure is not required. • COMM 54.15(3) Fire extinguishers are required to be provided in accordance with COMM 51.22. • COMM 50.12 This review does not include heating, ventilating or air conditioning. The owner should be reminded that HVAC plans, calculations, a completed SBD-118 application form and appropriate fees are required to be submitted for review and approval prior to installation. COMM 63.01 Prior to installation, lighting plans and calculations shall be prepared in compliance with the code and properly signed and sealed. The plans shall be available at the job site as requested by the Department representative or local official. 002 co * 9 pally AP ROVED DEPART ENT OF COMMERCE OMSWN AFETY AND BUILDINGS SEE CMRESPONDENCE 14'-O" r- (�2� PLAN OF TRASH/REGYGLE AI 5GALE 1/4" = 1'-0" - i 5X5 TREATED POSTS ENCLOSURE ELEVATION OF TRASH/REGYGLE ENCLOSURE 5GALE 1/4" = 1'-0" R O O a� d) o O \ o 1z z O E- v N z O o w in d O O C u_ u_ O p CN Of VJ iR Vk d 4b � 0 o �11i=0 J Z R � o LL w w 15'-0" ❑ HANDICAP : PARKING 516N, TYP, o O ❑ � y5 'S W l� Q ci = a � O � dJ O 20 O lb'-O" 2 4� 0 0 23'-0" 12'-0" - 9 5PAGE5 @ Y-O" n in - m 201 : 0 TRASH ENGL05URE O � j vti N � 24, + PROP05ED BUILDING 14'-O Ll W 4X4 TREATS[ 4' 0" - 3 5PAGE5 �I cz erg, 2 NOTE: 51TE DIMEN51ON5 ARE APPROXIMATE 015TANGE5. GONTRAGTOR TO VERIFY 5ETBAGK5 AND 51TE DIMEN51ON5. SITE PLAN 5GALE 1152" = 1'-0" TOTAL PARKING 5PAGE5 = 35 5TANDARD 5PAGE5 4 HANDIGAP 5PAGE5 NORTH (D PLAN OF TRASH/RECYCLE ENGLOSURE 56ALE 1/4" = 1'-0" X6 TREATED BOARDS 2X4 TREATED FRAME HEAVY DUTY HINGES HEAVY DUTY LATCH I I I I I I I I I I I I .� 5X5 TREATED POSTS ELEVATION OF TRASH/RECYCLE ENGLOSURE SCALE 1/4" = 1'-0" o O O lz z O zp m w d o O � O u- 0 N m d' � � o lu