Loading...
HomeMy WebLinkAbout012-640-09-2110-LUP-2003-6221072'-41Yl6" 144'-0" Cy? � a PROPOSED o BUILDING s r i N CV 662'-5w PROPERTY LINES DESIGN LOADS ROOF LOAD GROUND SNOW LOAD (PS) = 50 PSF SNOW INPORTANCE FACTOR (Is) = 1 SNOW LOAD EXPOSURE FACTOR (Ce) = 1.0 FLAT ROOF SNOW L.AOD (PE) = 50 PSF ROOF THERMAL FACTOR (Ct) = 1.1 SLOPED ROOF FACTOR (Cs) = 0.94 BALANCED ROOF SNOW LOAD (Ps) S PSF UNBALANCED SNOW LOAD = 0 PS WIND LOAD 90 MPH WIND, EXPOSURE 'C' INTERNAL PRESSURE COEFFICIENT = GC Pi = t Q18 COMPONENT & CLADDING DESIGN PRESSM = t18.8 PSF BUILDING ENCLOSURE TYPE = ENCLOSED WIND IMPORTANCE FACTOR m = LO SEISMIC LOAD SEISMIC USE GROUP "I" SITS CLASS ='w DESIGN CATAGORY "A" = ate' = Q06� SPECTRAL RESPONSE COEFFI� Sds WIND GOVERNS LATERAL DESIGN CRrMRLA FLOOR GOAD NONE 70' 0" RE FSQL G. donally r COVED MmERCE E7'YAN III nninn I -•--� N,,, I =I PON '��11fI01S� 4,.,ScoN` r�i +% r,,,.......r Syr • * t AARON J. HALBERG V. 34982 'A'!- HAYWARD fi.,rr WIS. ,.•t� /� {�p r�. rofo.,A` � p N At- %% /1111�� rn rn L__ N 1 /2 NW 1 /4 SECTION 9 1 T40N—R6W, TOWN OF HUNTER f ti SAWYER COUNTY, WISC;ONSIN. CS INFORMATION BY APEX 0 SURVEYING. o f, 0 6.95 ACRES , o , --� i SITE PLAN PROPOSED BUILDING IS A TYPE VB COMMERCIAL BUILDING UNHEATED UNOCCUPIED BUILDING WITHOUT FACILITIES. BUILDING OWNER: PETER CZARNECKI, PRC ENTERPRISES 9150W JOHNSON ROAD, HAYWARD WI 54843 IF PARKING IS PROVIDED HANDICAP ACCESSIBLE SPACES TO BE PROVIDED AT THE RAt'E OF 1 PER 25 STALLS, MINIMUM = 1. WITH APPROPRIATE SIGNAGE AND APPROACH SURFACES. AIF 1sconsin Department of Commerce September 04, 2003 CUST ID No.905255 AARON J HALBERG HALBERG ENGINEERING 10335 N DUFFY RD HAYWARD WI 54843 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 09/04/2005 SITE: PRC Enterprises Hwy B Town of Hunter, 54843 Sawyer County S9, T40N, R6W Facility: PRC Enterprises Boat Storage Building FOR: Safety and Buildings 10541 N RANCH ROAD HAYWARD WI 54843 TDD #: (608) 264-8/77 www.cornmerce.statemi.us/sb www.wisconsin.gov Jim Doyle, Governor Cory L. Nettles, Secretary ATTN.• Buildings & Structures Inspector MUNICIPAL CLERK TOWN OF HUNTER 9316 N COUNTY ROAD CC HAYWARD WI 54843-6616 Identification Numbers Transaction,ID No. 904503 / 918579 Site ID No. 664327 Please refer to both identification numbers, above, in all correspondence with the agency. Hwy B, Hayward 54843 Object Type: Building ICC Regulated Object ID No.: 918703 �4'-0" N __ 0 -- OPOSED ILDING rn 70'-0" FUTURE O BLDG. 1 o n 10 Minor Occupancy: Storage; Type VB Combustible Unprotected class of construction; New/revised plan; 8,640 project sq ft; Unsprinklered; Occupancy: S-2 Storage Low -Hazard; Component included in this transaction: Truss, Roof; P F' Allowable area determined by: Unseparated Use BF ROVED Object Type: Truss, Roof Regulated Object ID No.: 920330 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Reminders • IBC 1403.2 Provide exterior walls with a weather resistant exterior wall envelope. Per Table 1405.2, the minimum nominal thickness of exterior steel wall panels is to be 0.0149 in. • IBC 1802.6 State the soil classification and design load -bearing capacity of the soil on the plans. Per the submitted structural calculations, the soil type at the site is type 4 firm. • IBC 2902.1 Since this building lacks toilet facilities, it is approved as unoccupied storage only. • IECC 101/Comm 63.0101/Comm 63.0002(2) This building is approved as an unheated storage building. A copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/installation/operation. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Col; 4 r tionally []IV—KTiV.f] 0 MMERQ t QF, ETYIAN I L__ N 1 /2 NW 1 /4 SECTION 9 T40N—R6W, TOWN SAWYER COUNTY, ti 1 OF HUNTER t WISCONS CS INFORMATION BY APEX SURVEYING. 6.95 ACRES / / / / / / SITE PLAN PROPOSED BUILDING IS A TYPE VB COMMERCIAL BUILDING UNHEATED, UNOCCUPIED BUILDING WITHOUT FACILITIES. BUILDING OWNER PETER CZARNECKI,- PRC ENTERPRISES 915OW JOHNSON ROAD, HAYWARD WI 54843 IF PARKING IS PROVIDED HANDICAP ACCESSIBLE SPACES TO BE PROVIDED AT THE RACE OF 1 PER 25 STALLS, MINIMUM = 1. WITH APPROPRIATE SIGNAGE AND APPROACH SURFACES. 0 m .+ N N a a m� W�r� wam Cn�0 J— �b :1Z w2W I� O P d < m U O w a V W w � O As Noted ,MAN BY AjH IMN 09/02/2003 ios Ha 2003-124 Mou Ha 1.f3